Acurácia da creatinina dosada em gota de sangue seca em papel de filtro para rastreamento da doença renal crônica

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorLugon, Jocemir Ronaldo-
Autor(es): dc.contributorMattos, Jorge Paulo Strogoff de-
Autor(es): dc.contributorBastos, Marcus Gomes-
Autor(es): dc.contributorSouza, Edison Regio de Moraes-
Autor(es): dc.contributorGraciano, Miguel Luiz-
Autor(es): dc.creatorSilva, Alan Castro Azevedo e-
Data de aceite: dc.date.accessioned2024-07-11T17:58:08Z-
Data de disponibilização: dc.date.available2024-07-11T17:58:08Z-
Data de envio: dc.date.issued2017-09-27-
Data de envio: dc.date.issued2017-09-27-
Data de envio: dc.date.issued2015-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/4688-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/761076-
Descrição: dc.descriptionA identificação precoce da doença renal crônica (DRC) em populações de risco é preconizada devido à elevada morbidade e mortalidade dessa patologia. O rastreamento é normalmente feito utilizando testes de baixo custo e pouco invasivos, como a detecção de albumina na urina ou a dosagem da creatinina sérica. Apresentamos nesse estudo uma forma alternativa inovadora e de simples execução para dosar a creatinina. Cento e seis pessoas com alto risco de desenvolverem DRC foram envolvidas. A idade dos participantes foi de 57 ± 12 anos, 78 (73,5%) eram do sexo feminino, 43 eram brancos (40,5%), 36 eram pardos (34%) e 27 negros (25,5%). Setenta e seis por cento alegaram serem hipertensos, 30% já sabiam ter diabetes, 37% disseram ter história familiar para DRC e 22% eram tabagistas. O índice de massa corpórea (IMC) foi de 29,5 ± 6,9 kg/m2, a pressão arterial sistólica foi de 125 mmHg (intervalo interquartil [IQR] 120-140 mmHg) e a pressão arterial diastólica de 80 mmHg (IQR 70-80 mmHg). A validade do teste feito com papel filtro foi calculada considerando como a variável de interesse uma taxa de filtração glomerular estimada menor que 60/ml/min/1,73m2, calculado pelas equações MDRD e CKD-EPI. Desta maneira, a sensibilidade do PF foi de 96% na equação MDRD e de 94% na CKD-EPI. O valor preditivo positivo foi de 96% para ambas equações. A acurácia mostrou um desempenho de 92% na MDRD e de 90% na CKD-EPI. O método de Bland e Altman mostrou que os valores de creatinina entre os dois testes estão numa faixa relativamente estreita (+0.68 mg/dL a -0.55 mg/dL) para um desvio padrão de ±1.96. Concluímos que a dosagem da creatinina em papel filtro é um teste pouco invasivo e apresentou um bom desempenho para rastrear a DRC.-
Descrição: dc.descriptionChronic kidney disease (CKD) screening is advisable in populations with risk factors for chronic kidney disease due to its high morbidity and mortality. It´s usually performed by sampling blood for creatinine and urine for albuminuria. Here we present an innovative and simpler method, by measuring creatinine in a dry blood spot on filter paper. One-hundred and six individuals at high risk for CKD were enrolled. Mean age was 57±12 years, 74% were female, 40% white, and 60% non-white. Seventy-six percent were hypertensive, 30% diabetic, 37% had family history of CKD, and 22% of smoking. The BMI was 29.5 ± 6.9 kg/m2, median systolic blood pressure was 125 mmHg (IQR 120-140 mmHg) and median diastolic blood pressure was 80 mmHg (IQR 70-80 mmHg). Adopting CKD with the found of a e_GFR60/ml/min/1,73m2 for MDRD and CKD-EPI equation, the sensitivity was 96% for MDRD and 94% in CKD-EPI. The positive predictive value was 96% for both equations. The accuracy was 92% in MDRD and 90% for CKD-EPI. . A Bland and Altman analysis showed a relatively narrow range of creatinine values differences (+0.68 mg/dL to -0.55 mg/dL) inside the ±1.96 SD, without systematic differences. Accordingly, the minimally invasive dry blood spot creatinine measurement disclosed good performance, and may be useful as a screening tool for CKD.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Federal Fluminense-
Publicador: dc.publisherNiterói-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectRastreamento-
Palavras-chave: dc.subjectDoença renal crônica-
Palavras-chave: dc.subjectCreatinina-
Palavras-chave: dc.subjectGota de sangue seca em papel filtro-
Palavras-chave: dc.subjectInsuficiência renal crônica-
Palavras-chave: dc.subjectDiagnóstico-
Palavras-chave: dc.subjectCreatinina-
Palavras-chave: dc.subjectScreening-
Palavras-chave: dc.subjectChronic kidney disease-
Palavras-chave: dc.subjectCreatinine-
Palavras-chave: dc.subjectDry blood spot test in paper filter-
Título: dc.titleAcurácia da creatinina dosada em gota de sangue seca em papel de filtro para rastreamento da doença renal crônica-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.