Desenvolvimento e caracterização de ligas de Mg-Zn-Ca obtidas por metalurgia do pó com potencial aplicação como biomaterial

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorCastro, José Adilson de-
Autor(es): dc.contributorhttp://lattes.cnpq.br/4613010410524009-
Autor(es): dc.contributorRibeiro, Alexandre Antunes-
Autor(es): dc.contributorhttp://lattes.cnpq.br/1106609472179988-
Autor(es): dc.contributorSantos, Claudinei dos-
Autor(es): dc.contributorhttp://lattes.cnpq.br/1355748902111663-
Autor(es): dc.contributorDaguano, Juliana Kelmy Macário Barboza-
Autor(es): dc.contributorhttp://lattes.cnpq.br/3896619537030413-
Autor(es): dc.contributorSantos, Ésoly Madeleine Bento dos-
Autor(es): dc.contributorhttp://lattes.cnpq.br/2729783053595892-
Autor(es): dc.contributorhttp://lattes.cnpq.br/9944356006840514-
Autor(es): dc.creatorCarvalho, Jorge Alberto de Medeiros-
Data de aceite: dc.date.accessioned2024-07-11T17:57:26Z-
Data de disponibilização: dc.date.available2024-07-11T17:57:26Z-
Data de envio: dc.date.issued2022-12-12-
Data de envio: dc.date.issued2022-12-12-
Fonte completa do material: dc.identifierhttp://app.uff.br/riuff/handle/1/27240-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/760843-
Descrição: dc.descriptionImplantes cirúrgicos bioabsorvíveis fabricados por metalurgia do pó não são comumente observados nos dias atuais. Entretanto, o uso da metalurgia do pó pode ser uma boa forma de se fabricar implantes cirúrgicos com distintas composições, a depender das necessidades estruturais do osso a ser recuperado, reduzindo os seus custos de fabricação devido ao alcance, quase que imediato, das formas dos implantes desejados (net shape). Neste estudo, três ligas diferentes de Mg-Zn-Ca, denominadas M1 (Mg5Zn1Ca), M2 (Mg29Zn2Ca) e M3 (Mg53Zn4Ca), foram fabricadas por metalurgia do pó, sendo investigadas nas suas propriedades metalográficas, mecânicas e de resistência à corrosão em um fluido corporal simulado (Kokubo) a fim de se verificar sua viabilidade como um dispositivo cirúrgico bioabsorvível. Dentre as ligas avaliadas, a M3 (Mg53Zn4Ca) foi considerada potencialmente utilizável como implante bioabsorvível devido a sua microestrutura com tamanhos de grãos de 108,3 ± 21 μm, presença de segundas fases, tais como, MgZn², Mg₂Zn₁₁, Mg₂Zn₃ e Ca₂Mg₆Zn₃ nas regiões eutéticas e das fases Mg₅₁Zn₂₀, Ca₂Mg₅Zn₁₃ e Mg₁₂Zn₁₃ na região semi-peritérica, seus resultados em resistência mecânica, apresentando valores de ultra-micro-dureza vickers da ordem de 46,4 ± 1,7, limite elástico de 483 ± 24 N/mm2 e módulo elástico de 23,0 ± 0,4 GPa. Em adicional, a liga M3 apresentou potencial de corrosão em circuito aberto de -1483 mV após 350 segundos de exposição em solução de Kokubo, polarização potencial-dinâmica em -1484 mV e densidade de corrente de corrosão da ordem de 0,9 mA / cm² na mesma solução, além de taxa de degradação de aproximadamente 1mg cm² / dia, o que é semelhante a outras ligas de Mg fundidas e tratadas termo-mecanicamente descritas na literatura.-
Descrição: dc.descriptionBioabsorbable surgical implants manufactured by powder metallurgy are not commonly seen nowadays. However, the use of powder metallurgy can be a good way to manufacture surgical implants with different compositions, depending on the structural needs of the bone to be recovered, reducing the manufacturing costs due to the almost immediate achievement of the desired implant shapes (net shape). In this study, three different alloys of Mg-Zn-Ca, named M1 (Mg5Zn1Ca), M2 (Mg29Zn2Ca) and M3 (Mg53Zn4Ca), were manufactured by powder metallurgy, and their metallographic, mechanical and corrosion resistance properties were investigated in a simulated body fluid (Kokubo) in order to verify their viability as a bioabsorbable surgical device. Among the alloys evaluated, M3 (Mg53Zn4Ca) was considered potentially usable as a bioabsorbable implant due to its microstructure with grain sizes of 108.3 ± 21 μm, presence of second phases such as, MgZn2, Mg2Zn11, Mg2Zn3 and Ca2Mg6Zn3 in the eutectic regions and the phases Mg51Zn20, Ca2Mg5Zn13 and Mg12Zn13 phases in the semi-periteric region, its results in mechanical strength, presenting ultra-micro Vickers hardness values of 46,4 ± 1.7, elastic limit of 483,0 ± 24 N/mm2 and elastic modulus of 23,0 ± 0,4 GPa. In addition, the M3 alloy showed an open circuit corrosion potential of - 1483 mV after 350 seconds of exposure in Kokubo solution, potential-dynamic polarization at -1484 mV and corrosion current density of 0.9 mA / cm2 in the same solution, and degradation rate of approximately 1mg cm2 / day, which is similar to other cast and thermo-mechanically treated Mg alloys described in the literature-
Descrição: dc.description84 p.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectMetalurgia do pó-
Palavras-chave: dc.subjectImplantes cirúrgicos bioabsorvíveis-
Palavras-chave: dc.subjectLigas de MgZnCa-
Palavras-chave: dc.subjectLiga metálica-
Palavras-chave: dc.subjectBiomaterial-
Palavras-chave: dc.subjectProdução intelectual-
Palavras-chave: dc.subjectModelamento e simulação de processos e fenômenos-
Palavras-chave: dc.subjectPowder metallurgy-
Palavras-chave: dc.subjectBioabsorbable surgical implants-
Palavras-chave: dc.subjectMg-Zn-Ca alloys-
Título: dc.titleDesenvolvimento e caracterização de ligas de Mg-Zn-Ca obtidas por metalurgia do pó com potencial aplicação como biomaterial-
Tipo de arquivo: dc.typeTese-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.