Síntese e caracterização de adesivos autocondicionantes experimentais com sistema tampão de hidróxido de cálcio - Ca(OH)2

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorSilva, Eduardo Moreira da-
Autor(es): dc.contributorhttp://lattes.cnpq.br/9042844666808162-
Autor(es): dc.contributorhttp://lattes.cnpq.br/0084980191573168-
Autor(es): dc.creatorGarcia, Marcelle Gonçalves-
Data de aceite: dc.date.accessioned2024-07-11T17:55:01Z-
Data de disponibilização: dc.date.available2024-07-11T17:55:01Z-
Data de envio: dc.date.issued2020-11-10-
Data de envio: dc.date.issued2020-11-10-
Data de envio: dc.date.issued2017-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/15882-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/760039-
Descrição: dc.descriptionMesmo após a polimerização, a acidez dos adesivos autocondicionantes pode degradar as estruturas da camada híbrida. Este projeto testou a hipótese nula de que a adição de Ca(OH)2 em adesivos autocondicionantes experimentais não tem efeito sobre a sua resistência de união. Quatro diferentes concentrações de Ca(OH)2 (0%, 1%, 2% e 4%) foram adicionadas a um adesivo experimental constituído por (% em peso): Primer: 10-MDP (30%), TEGDMA (30%), Etanol (35%), água (5%), canforoquinona (0,5%), EDMAB (0,5%) e Adesivo: Bis-GMA (50%), TEGDMA (30%), HEMA %), EDMAB (0,5%). O potencial de tamponamento foi avaliado até atingir o equilíbrio e o grau de conversão dentro da camada híbrida através de espectrômetro / microscópio micro-Raman (Horiba Scientific Xplora, Villeneuve d’Ascq, França) equipado com um laser de diodo 785-nm e uma objetiva X100/0.9 NA. Os adesivos foram aplicados à dentina coberta com uma camada de smear layer padronizada e os blocos de resina composta foram construídos através da técnica incremental. Após armazenamento em saliva artificial durante 24 h, os dentes foram cortados em barras de dentina de resina que foram submetidas ao teste de resistência de união por microtração (μTBS). A nanoinfiltração foi avaliado através do microscópio eletrônico de varredura (MEV). Os dados foram submetidos à analise de variância de um fator e teste de Tukey (=0,05). O potencial tampão dos adesivos aumentou com o aumento da concentração de Ca (OH)2 (p <0,05). A incorporação de Ca(OH)2 não comprometeu a adesão à dentina (p> 0,05). O adesivo com 4% de Ca(OH)2 apresentou a menor nanoinfiltração. São necessários mais estudos para investigar o desempenho em longo prazo destes adesivos-
Descrição: dc.descriptionEven after polymerization, the acidity of self-etching adhesives may degrade the structures of the hybrid layer. We tested the null hypothesis that adding Ca(OH) 2 into self-etching primers has no effect on bonding performance of model self-etching adhesive systems. Four different concentrations of Ca(OH)2 (0%, 1%, 2% and 4%) were added to a model adhesive consisting of (wt%): Primer: 10-MDP (30%), TEGDMA (30%), ethanol (35%), water (5%), camphorquinone (0.5%), EDMAB (0.5%) and Adhesive: Bis-GMA (50%), TEGDMA (30%), HEMA (20%), camphorquinone (0.5%), EDMAB (0.5%). The buffering potential was evaluated until reach equilibrium, and the degree of conversion within the hybrid layer by micro-Raman spectrometer/microscope (Horiba Scientific Xplora, Villeneuve d’Ascq, France) with a 785-nm diode laser through a X100/0.9 NA air objective. The adhesives were applied to smear-layer-covered dentin and resin composite buildups were incrementally constructed. After storage in artificial saliva during 24 h, the teeth were cut into resin dentins beams that were submitted to microtensile bond strength (µTBS) test. Nanoleakage was evaluated by SEM. The buffering potential of adhesives increased with the increasing of Ca(OH)2 concentration (p < 0.05). The incorporation of Ca(OH)2 did not jeopardize the bonding to dentin (p > 0.05). The adhesive with 4% of Ca(OH)2 presented the lowest nanoleakage. Further studies are needed to investigate the long-term performance of these adhesives-
Descrição: dc.description43f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectTeste de adesão-
Palavras-chave: dc.subjectResistência de união-
Palavras-chave: dc.subjectHidróxido de cálcio-
Palavras-chave: dc.subjectAdesivos-
Palavras-chave: dc.subjectAdesivo dentinário-
Palavras-chave: dc.subjectHidróxido de cálcio-
Palavras-chave: dc.subjectColagem dentária-
Palavras-chave: dc.subjectInfiltração dentária-
Palavras-chave: dc.subjectAdhesive testing-
Palavras-chave: dc.subjectBond strength-
Palavras-chave: dc.subjectCalcium hydroxide-
Palavras-chave: dc.subjectAdhesives-
Título: dc.titleSíntese e caracterização de adesivos autocondicionantes experimentais com sistema tampão de hidróxido de cálcio - Ca(OH)2-
Título: dc.titleModel self-etch adhesive system with calcium hydroxide buffer-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.