Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Silva, Eduardo Moreira da | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/8923032431096718 | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/0084980191573168 | - |
Autor(es): dc.creator | Miragaya, Luciana Meireles | - |
Data de aceite: dc.date.accessioned | 2024-07-11T17:53:13Z | - |
Data de disponibilização: dc.date.available | 2024-07-11T17:53:13Z | - |
Data de envio: dc.date.issued | 2019-09-18 | - |
Data de envio: dc.date.issued | 2019-09-18 | - |
Data de envio: dc.date.issued | 2012 | - |
Fonte completa do material: dc.identifier | https://app.uff.br/riuff/handle/1/11335 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/759473 | - |
Descrição: dc.description | O objetivo do presente estudo foi avaliar a influência de quatro tratamentos de superfície na estabilidade de união entre um cimento resinoso auto-adesivo e uma cerâmica a base de zircônia estabilizada por ítrio (Y-TZP). Para que isso fosse possível, o estudo foi dividido em duas etapas. Na primeira, quarenta placas (8x6x1mm) de uma cerâmica Y-TZP foram divididas aleatoriamente em quatro grupos (n=10) de acordo com o tratamento de superfície utilizado: Controle - sem tratamento; Jateamento com Al2O3 (50µm); aplicação de primer a base de MDP; e condicionamento com Sistema Rocatec. As placas cerâmicas tratadas com cada um dos tratamentos foram divididas em 2 sub-grupos em função do cimento resinoso testado: RelyX ARC (ARC - cimento resinoso convencional) e RelyX Unicem (UCem - cimento resinoso auto-adesivo). Os cimentos resinosos foram aplicados no interior de tubos de PVC (0,75mm de diâmetro e 0,5mm de altura) posicionados sobre a placa cerâmica. Após o armazenamento em água a 37oC por 24h, os espécimes foram submetidos ao ensaio de micro-cisalhamento a uma velocidade de 1mm/min. Os resultados dessa primeira fase do experimento mostraram que os tratamentos de superfície influenciaram significativamente a resistência de união (p < 0,05). Para os quatro tratamentos de superfície, UCem apresentou resultados significativamente maiores do que o ARC (p < 0,05). Para ambos os cimentos, o melhor resultado foi produzido pelo primer a base de MDP: ARC - 15,9 + 5,0MPa e UCem - 36,2 + 2,1MPa. Os maiores valores de resistência foram apresentados pelos grupos que combinaram o UCem ao uso de primer a base de MDP (36.2 ± 2.1 MPa) e ao condicionamento com o sistema Rocatec (37.4 ± 2.3 MPa). A segunda etapa do estudo, teve como objetivo verificar a estabilidade da união obtida com os tratamentos de superfície. Para tanto, a metodologia foi repetida e novos espécimes, combinando os mesmos tratamentos de superfície e cimentos utilizados na primeira etapa, foram confeccionados e armazenados em água destilada a 37oC por 6 meses. Após a imersão, os mesmos foram submetidos ao ensaio de microcisalhamento. Esta segunda fase mostrou que à exceção dos espécimes que combinaram o cimento ARC ao tratamento com o sistema Rocatec, todos os demais tiveram sua resistência diminuída após o armazenamento em água (p < 0,05). Para o UCem a queda foi de 54,8% nas cerâmicas tratadas com Rocatec e de 52,8% nas tratadas com o primer. No grupo que combinou o ARC ao tratamento da superfície cerâmica com primer a base de MDP a queda foi de 42,5%. Pode-se concluir, dentro das limitações deste estudo, que nenhum dos tratamentos de superfície foi capaz de tornar estável e confiável a união entre o cimento resinoso auto-adesivo e a cerâmica Y-TZP após seis meses em água | - |
Descrição: dc.description | The objective of the present study was to evaluate the influence of four surface treatments on the stability of the bond strength between a self-adhesive resin cement and an yttria-stabilized zirconia (Y-TZP) ceramic material (Lava Frame zirconia). To make this possible, the study was divided in two parts. On the first stage, forty plates (8x6x1mm) of a Y-TZP ceramic restorative material were randomly assigned to four groups (n = 10) according to the surface treatments: Control – no treatment, airborne-particle abrasion with 50-µm Al2O3, coating with a MDP-based primer and conditioning with Rocatec System. The ceramic plates treated with each of the four methods were further divided into 2 subgroups according to the resin cement tested: RelyXTM ARC (ARC - conventional) and RelyXTM Unicem (UCem - self-adhesive). The resin cements were put into PVC tubes (∅ = 0.75 mm x 0.5 mm height) placed on the ceramic plate surfaces. After water storage at 37oC for 24h, the specimens were submitted to a micro-shear bond strength (µSBS) test at a crosshead speed of 1.0mm/min. The results of the first part of the present study showed that the surface treatments significantly influenced the µSBS (p < 0.05). For the four surface treatments, UCem presented significantly higher µSBS than ARC (p < 0.05). For both resin cements, the best result was produced by MDP-based primer: ARC - 15.9 ± 5.0 MPa and UCem - 36.2 ± 2.1MPa. The highest µSBS values were presented by UCem on ceramic plates treated with MDP-based primer (36.2 ± 2.1 MPa) and Rocatec system (37.4 ± 2.3 MPa). The second stage of the study was to verify the stability of the union obtained. For this, the methodology was repeated and new specimens, combining the same surface treatments and cements used in the first stage, were made and stored in distilled water at 37oC for 6 months. After storage, the specimens were submitted to micro-shear test. This second phase showed that the highest µSBS values were presented by UCem in the specimens tested after 24 h (MDP = 37.4 ± 2.3 and TSC = 36.2 ± 2.1 MPa). Excepting for ARC applied on ceramic surfaces treated with TSC, all the other groups presented a dropping on µSBS after six months water aging (p < 0.05). For UCem, the drop was -54.8% in ceramic surfaces treated with TSC and -52.8% in ceramic surfaces treated with MDP-based primer. In the group treated with MDP-based primer the drop in µSBS for Rely X ARC was -42.5%. It can be concluded, within the limitations of this study, that none of the surface treatments were able to stabilize the adhesion between the self-adhesive resin cement and the Y-TZP ceramic over six months water aging | - |
Descrição: dc.description | 66f. | - |
Formato: dc.format | application/pdf | - |
Idioma: dc.language | pt_BR | - |
Direitos: dc.rights | openAccess | - |
Direitos: dc.rights | CC-BY-SA | - |
Palavras-chave: dc.subject | Y-TZP | - |
Palavras-chave: dc.subject | Tratamento de superfície | - |
Palavras-chave: dc.subject | Cimento resinoso | - |
Palavras-chave: dc.subject | Cimento auto-adesivo | - |
Palavras-chave: dc.subject | Resistência de união | - |
Palavras-chave: dc.subject | Tratamento de superfície | - |
Palavras-chave: dc.subject | Cimento dentário | - |
Palavras-chave: dc.subject | Resistência do material | - |
Palavras-chave: dc.subject | Adhesion | - |
Palavras-chave: dc.subject | Surface treatment | - |
Palavras-chave: dc.subject | Resin cements | - |
Palavras-chave: dc.subject | Shear bond strength | - |
Título: dc.title | Influência de diferentes tratamentos de superfície na estabilidade de união entre cerâmica estabilizada por ítria e cimentos resinosos | - |
Título: dc.title | The Influence of different surface treatment on the bond between two resin cement and an yttria-stabilized zirconia ceramic | - |
Tipo de arquivo: dc.type | Dissertação | - |
Aparece nas coleções: | Repositório Institucional da Universidade Federal Fluminense - RiUFF |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: