Estudo para obtenção de imagens radiográficas intraorais com qualidade e utilizando dose de radiação adequada

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorMaia, Mônica Diuana Calasans-
Autor(es): dc.contributorAlmeida, Claudio Domingues de-
Autor(es): dc.contributorhttp://lattes.cnpq.br/5401936006137573-
Autor(es): dc.contributorhttp://lattes.cnpq.br/9052519251465705-
Autor(es): dc.contributorhttp://lattes.cnpq.br/5998994922135357-
Autor(es): dc.creatorPereira, Gustavo Viana Cople-
Data de aceite: dc.date.accessioned2024-07-11T17:51:34Z-
Data de disponibilização: dc.date.available2024-07-11T17:51:34Z-
Data de envio: dc.date.issued2020-09-21-
Data de envio: dc.date.issued2020-09-21-
Data de envio: dc.date.issued2015-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/14954-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/758944-
Descrição: dc.descriptionO objetivo deste estudo é indicar diretrizes para que cirurgiões-dentistas possam obter boas imagens radiográficas em filmes periapicais utilizando um processo controlado, individualizado e testado. Foi selecionada a dose de 2,6 mGy para irradiar os filmes radiográficos, que é considerada uma dose inferior à recomendação da legislação brasileira, próxima das doses utilizadas em outros estudos sobre qualidade de imagem e maior do que as recomendações do fabricante do filme radiográfico utilizado. Tabelas diferentes de tempo X temperatura foram testadas usando tempos curtos de processamento de filme para 6 temperaturas diferentes. Os filmes após revelados foram avaliados para verificação da densidade ótica por oito observadores de qualidade de imagem. Os observadores que participaram deste estudo preferiram as imagens obtidas pelos tempos de revelação mais curtos, entre 2,5 minutos e 40 segundos. Só foi encontrada diferença estatisticamente significativa (p <0,05) quando se comparou um filme que teve boa aceitação pelos observadores com um filme que teve má aceitação pelos observadores. Através desse estudo, foi considerada viável a possibilidade de realizar imagens radiográficas periapicais de boa qualidade, usando baixas doses de radiação e ainda utilizar um reduzido tempo de revelação.-
Descrição: dc.descriptionThe purpose of this study was to indicate a guideline for low dose quality images in intraoral dental radiology by using a controled, individualized and tested film processing. The x-ray dose used for study was 2.6 mGy. This dose is lower than the brazilian law recommendation, near to other low dose studies and higher than film manufacturer recommendation. 3 different time x temperature tables were tested by using 3 different short time film processing for 6 different temperatures. After processing the films were tested by optical densitometry and by 8 image quality judges. The judges in this study preferred the images obtained by the short processing times between 2,5 minutes and 40 seconds. Only when comparing a high scored film with a low scored film it was found a significant statistical difference ( P < 0,05 ). It is possible to stablish low dose x-ray imaging with short time film processing and still have good quality image results. You only have to individualize, test and control your film processing at your own dental office.-
Descrição: dc.description43f.-
Formato: dc.formatapplication/msword-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectRadiografia dentária-
Palavras-chave: dc.subjectDensitometria-
Palavras-chave: dc.subjectControle de qualidade-
Palavras-chave: dc.subjectRadiografia dentária-
Palavras-chave: dc.subjectDensitometria-
Palavras-chave: dc.subjectControle de qualidade-
Palavras-chave: dc.subjectX-Rays-
Palavras-chave: dc.subjectDensitometry-
Palavras-chave: dc.subjectRadiography-
Palavras-chave: dc.subjectQuality control-
Título: dc.titleEstudo para obtenção de imagens radiográficas intraorais com qualidade e utilizando dose de radiação adequada-
Título: dc.titleGuideline for low dose quality images in intraoral dental radiology-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.