Efeito de ácidos presentes no biofilme oral na absorção e solubilidade de diferentes sistemas adesivos autocondicionantes

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorAmaral, Cristiane Mariote-
Autor(es): dc.contributorhttp://lattes.cnpq.br/2524442767433537-
Autor(es): dc.contributorhttp://lattes.cnpq.br/4525957878849519-
Autor(es): dc.creatorMiranda, Maria Elisa da Silva Nunes Gomes-
Data de aceite: dc.date.accessioned2024-07-11T17:38:12Z-
Data de disponibilização: dc.date.available2024-07-11T17:38:12Z-
Data de envio: dc.date.issued2020-07-10-
Data de envio: dc.date.issued2020-07-10-
Data de envio: dc.date.issued2012-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/14279-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/754325-
Descrição: dc.descriptionO objetivo deste trabalho foi avaliar a absorção e a solubilidade de sistemas adesivos autocondicionantes após imersão em água destilada e ácidos produzidos no biofilme oral. Três sistemas adesivos foram selecionados: um de dois passos para uso com a resina composta à base de silorano (P90 System Adhesive - P90), um de passo único (Adper Easy One - AEO) e outro de dois passos (Clearfil SE Bond – CSE). As amostras foram confeccionadas com auxílio de uma matriz metálica de 6 mm de diâmetro e 1 mm de altura, de acordo com os grupos a seguir: primer do P90 (P90-P), adesivo do P90 (P90-A), AEO, adesivo do CSE (CSE-A) e a mistura do primer com o adesivo do CSE (CSE-P+A). As amostras foram fotopolimerizadas por 40 segundos de cada lado e em seguida, foram acondicionadas em dissecador com sílica gel azul e pesadas diariamente até a obtenção de massa constante (m 1 ). Após este período, as amostras (n=5) foram imersas em 10 ml dos seguintes meios de imersão: água destilada, ácido lático e ácido propiônico. As amostras foram pesadas em intervalos de tempo pré-definidos até a obtenção de massa constante durante 3 dias consecutivos (m 2 ). Após esse processo, as amostras passaram novamente por um processo de secagem para a obtenção de m 3 . Após verificação da normalidade da distribuição e da homogeneidade das variâncias, os dados de solubilidade e absorção foram analisados separadamente através da Analise de Variância de dois fatores (adesivo e meio de imersão) e do Teste de Tukey. Os maiores valores de absorção, para todos os meios, foram obtidos para a mistura CSE P+A, seguido pelo AEO, P90-P, CSE-A e P90-A. AEO e P90-P apresentaram valores semelhantes nos meios ácidos. A absorção foi maior em água para os adesivos AEO e CSE P+A do que nos ácidos, onde tiveram resultados semelhantes. Quanto à solubilidade, os maiores valores foram para o grupo CSE P+A, seguido pelo AEO e P90-P (semelhantes entre si), em todos os meios de imersão. Em água e em ácido propiônico, os adesivos com menores valores de solubilidade foram CSE-A e P90-A. Já em ácido lático, o CSE-A apresentou a menor solubilidade.-
Descrição: dc.descriptionThe aim of this study was to evaluate the sorption and solubility of self-etch adhesive systems after immersion in distilled water and acids present in oral biofilm. Three adhesive systems were selected: a two-step for use with silorane composite resin- based (P90 System Adhesive - P90), a single step (Adper Easy One - AEO) and another two-step (Clearfil SE Bond - CSE) Specimens were prepared using a metal matrix 6 mm in diameter and 1 mm thick, according to groups: P90 primer (P90-P), P90 adhesive (P90-A), AEO, CSE adhesive (CSE-A) and the CSE primer/adhesive mixture (CSE P+A). Specimens were light polymerized for 40 seconds on each side, then placed in a desiccator with blue silica gel and weighed daily until achieving constant mass (m 1 ). After this, specimens (n=5) were immersed in 10 ml of the following media: distilled water, lactic acid and propionic acid. Specimens were weighed at predetermined intervals on three consecutive days (m 2 ) until constant mass was obtained. Next, specimens were desiccated again (m 3 ). After verifying normality of distribution and homogeneity of variance, sorption and solubility data were analyzed by two-way Analysis of Variance (adhesive and immersion media) and Turkey’s test. The highest absorption values for all the immersion media were obtained for mixture CSE P+A, followed by AEO, P90-P, CSE-A and P90-A. AEO and P90-P had similar values in acidic media. For adhesives CSE P+A and AEO, sorption in water was higher than it was in acids, in which they showed similar results. For solubility, the highest values were shown for CSE P+A, followed by AEO and P90-P (similar to each other), in all immersion media. In water and propionic acid, adhesives with lowest solubility values were CSE-A and P90-A. Whereas in lactic acid, CSE-A had the lowest solubility.-
Descrição: dc.description46f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectSistemas adesivos-
Palavras-chave: dc.subjectAbsorção-
Palavras-chave: dc.subjectSolubilidade-
Palavras-chave: dc.subjectÁcidos orgânicos-
Palavras-chave: dc.subjectPlaca dentária-
Palavras-chave: dc.subjectAdesivo dentinário-
Palavras-chave: dc.subjectSolubilidade-
Palavras-chave: dc.subjectAdhesives systems-
Palavras-chave: dc.subjectAbsorption-
Palavras-chave: dc.subjectSolubility-
Palavras-chave: dc.subjectOrganic acids-
Título: dc.titleEfeito de ácidos presentes no biofilme oral na absorção e solubilidade de diferentes sistemas adesivos autocondicionantes-
Título: dc.titleEffect of acids present in oral biofilm on the sorption and solubility of different self-etch adhesive systems-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.