Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | França, Bruno Wanderley | - |
Autor(es): dc.contributor | Bitencourt, Leonardo de Arruda | - |
Autor(es): dc.contributor | Pereira, Alexandre de Mattos | - |
Autor(es): dc.contributor | Pinto Filho, Gilberto Figueiredo | - |
Autor(es): dc.creator | Lopes, Victoria Dos Santos | - |
Data de aceite: dc.date.accessioned | 2024-07-11T17:36:57Z | - |
Data de disponibilização: dc.date.available | 2024-07-11T17:36:57Z | - |
Data de envio: dc.date.issued | 2023-01-01 | - |
Data de envio: dc.date.issued | 2023-01-01 | - |
Fonte completa do material: dc.identifier | http://app.uff.br/riuff/handle/1/27462 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/753896 | - |
Descrição: dc.description | No mercado de geração distribuída diferentes topologias de usinas fotovoltaicas apresentam características próprias quanto à obtenção da máxima geração dos módulos fotovoltaicos. Assim, o presente trabalho aborda a capacidade de condução de corrente dos cabos, o encaminhamento de canaletas, arranjos de aterramento e avalia a viabilidade financeira de uma usina solar fotovoltaica de 1 MW, que será instalada no campus da UFF no município de Iguaba-RJ. A metodologia utilizada para o desenvolvimento desse estudo de viabilidade financeira consistiu em levantar os custos atrelados a esse empreendimento, calcular o valor economizado com a implantação da usina, e, com base nesses valores, calcular os indicadores financeiros, nesse caso o Valor Presente Líquido (VPL), o Tempo de Retorno Simples, Taxa Interna de Retorno (TIR) e o Custo Nivelado de Energia (LCOE). Para o projeto de instalação elétrica serão feitos os cálculos para capacidade de condução de corrente, queda de tensão e proteção dos cabos da instalação de corrente contínua. Os resultados mostram que os cabos de baixa tensão terão seções de 50 mm² e 16 mm², e o cabo solar terá seção de 4,0 mm². Os fusíveis de proteção para as para linhas de 12 e 13 séries fotovoltaicas serão de 250 A, para as linhas de 5 séries fotovoltaicas de 100 A, e para a série fotovoltaica do sistema fotovoltaico será um fusível gPV de 25 A. Um sistema fotovoltaico de 1 MW de GD apresentou um VPL de R$ 2.027.055,84, um TIR de 17,31%, um tempo de retorno simples de 7 anos, e um LCOE de 0,19 R$/kWh para o cenário atual, portanto, os resultados foram positivos. | - |
Descrição: dc.description | In the distributed generation market, different topologies of photovoltaic plants have their own characteristics in terms of obtaining the maximum generation of photovoltaic modules. Thus, the present work addresses the current conduction capacity of the cables, the routing of channels, grounding arrangements and evaluates the financial viability of a 1 MW photovoltaic solar plant, which will be installed on the UFF campus in the municipality of Iguaba-RJ. The methodology used for the development of this financial feasibility study consisted of raising the costs linked to this undertaking, calculating the amount saved with the implementation of the plant, and, based on these values, calculating the financial indicators, in this case the Net Present Value (NPV), Simple Return Time, Internal Rate of Return (IRR) and Levelized Cost of Energy (LCOE). For the electrical installation project, calculations will be made for current conduction capacity, voltage drop and protection of the direct current installation cables. The results show that the low voltage cables will have sections of 50 mm² and 16 mm², and the solar cable will have a section of 4.0 mm². The protection fuses for the 12 and 13 photovoltaic series lines will be 250 A, for the 5 photovoltaic series lines of 100 A, and for the photovoltaic series of the photovoltaic system will be a 25 A gPV fuse. 1 MW of DG had a NPV of R$ 2,027,055.84, an IRR of 17.31%, a simple payback time of 7 years, and an LCOE of 0.19 R$/kWh for the current scenario, therefore, the results were positive. | - |
Descrição: dc.description | 82 p. | - |
Formato: dc.format | application/pdf | - |
Idioma: dc.language | pt_BR | - |
Direitos: dc.rights | Open Access | - |
Direitos: dc.rights | CC-BY-SA | - |
Palavras-chave: dc.subject | Geração Solar | - |
Palavras-chave: dc.subject | Análise Financeira | - |
Palavras-chave: dc.subject | Dimensionamento de Usinas Fotovoltaicas | - |
Palavras-chave: dc.subject | Usina termossolar | - |
Palavras-chave: dc.subject | Geração de energia | - |
Palavras-chave: dc.subject | Viabilidade econômico-financeira | - |
Palavras-chave: dc.subject | Solar Generation | - |
Palavras-chave: dc.subject | Financial analysis | - |
Palavras-chave: dc.subject | Sizing of Photovoltaic Plants | - |
Título: dc.title | Aspectos gerais de Instalação elétrica em análise de viabilidade econômica de uma usina solar fotovoltaica: o caso de Iguaba Grande | - |
Tipo de arquivo: dc.type | Trabalho de conclusão de curso | - |
Aparece nas coleções: | Repositório Institucional da Universidade Federal Fluminense - RiUFF |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: