Discrepância vertical no posicionamento de pilares cone morse submetidos à diferentes forças de torque

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorCasado, Priscila Ladeira-
Autor(es): dc.contributorhttp://lattes.cnpq.br/5162476793291873-
Autor(es): dc.contributorFonseca, Edgard de Mello-
Autor(es): dc.contributorhttp://lattes.cnpq.br/4161140131440509-
Autor(es): dc.creatorCordeiro, Bruno Queiroz da Silva-
Data de aceite: dc.date.accessioned2024-07-11T17:36:07Z-
Data de disponibilização: dc.date.available2024-07-11T17:36:07Z-
Data de envio: dc.date.issued2022-11-28-
Data de envio: dc.date.issued2022-11-28-
Fonte completa do material: dc.identifierhttp://app.uff.br/riuff/handle/1/27102-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/753617-
Descrição: dc.descriptionA adaptação das próteses implantossuportadas é crucial para a estabilidade protética, influenciando diretamente na longevidade do tratamento reabilitador com implante endósseo. Sendo assim, o objetivo deste estudo foi avaliar a influência do torque manual (10N/cm) e do torque clínico (30N/cm), recomendado pelo fabricante, nos comprimentos totais dos pilares de implantes tipo Cone Morse. Foram confeccionados 20 corpos de provas, dividos em 2 grupos: O grupo 1 com 10 análogos para implante do tipo Cone Morse e o Grupo 2 com 10 implantes do tipo Cone Morse, de dimensão 4,3X15cm. Sobre cada implante e análogo, utilizou-se 20 pilares de preparo de 1,5mm de cinta, aparafusados com um torquímetro universal. Em cada grupo, o pilar foi submetido ao torque de 10N/cm, sendo feita a primeira medição da altura do pilar. Em seguida, foi aplicado o torque de 30N/cm, no mesmo pilar, sendo feita a segunda medição da altura do pilar. A medição da distância entre o topo do pilar e a topo do implante/análogo foi realizada no Laboratório de Calibração Brasil Mitutoyo. Considerando a análise comparativa entre os torques de 10N/cm e 30N/cm, nos grupos 1 e 2, houve diferença na altura do pilar, com maior distância no torque de 10N/cm, em ambos os grupos. De forma a verificar a repricabilidade clínica do experimento, as comparações entre a altura do pilar no análogo, em 10N/cm, e no implante, em 30N/cm foram realizadas, evidenciando maior discrepância no torque de 10N/cm no análogo (p=0.03). De forma a verificar se a alteração no protocolo laboratorial de 10N/cm para 30N/cm poderia minimizar as diferenças nas alturas dos pilares protéticos, comparou-se a altura do pilar nos grupos 1 e 2 com 30N/cm, não sendo observada diferença significante (p=0.30). Concluímos que, o torque manual e o torque recomendado pelo fabricante influenciam no comprimento total dos pilares protéticos, de implantes Cone Morse.-
Descrição: dc.descriptionThe adaptation of implant-supported prostheses is crucial for prosthetic stability, directly influencing the longevity of endosseous implant rehabilitation treatment. Therefore, the aim of this study was to evaluate the influence of manual torque (10N/cm) and clinical torque (30N/cm), recommended by the manufacturer, on the total length of Morse Cone implant abutments. Twenty specimens were made and divided into 2 groups: Group 1 with 10 analogs for Cone Morse type implant and Group 2 with 10 Cone Morse type implants, size 4.3x15cm. Over each implant and analog, 20 1.5mm preparation abutments were screwed together with a universal torque wrench. In each group, the abutment was subjected to a torque of 10N/cm, and the first measurement of abutment height was made. Then, the 30N/cm torque was applied to the same abutment, and the second abutment height measurement was made. The distance between the top of the abutment and the implant / analog base was measured at the Brazil Mitutoyo Calibration Laboratory. Considering the comparative analysis between the torques of 10N/cm and 30N/cm, in groups 1 and 2, there was a difference in abutment height, with greater torque distance of 10N/cm, in both groups. In order to verify the clinical reproducibility of the experiment, comparisons between the abutment height of the analog at 10N /cm and the implant at 30N / cm were performed, showing a greater discrepancy in the torque of 10N/cm in the analog (p = 0.03). In order to verify if the change in the laboratory protocol from 10N/cm to 30N/cm could minimize the differences in the height of the prosthetic abutments, the abutment height in groups 1 and 2 was compared with 30N /cm, and no significant difference was observed. (p=0.30). We conclude that the manual torque and the torque recommended by the manufacturer influence the total length of the prosthetic abutments of Cone Morse implants.-
Descrição: dc.description44 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectCone Morse-
Palavras-chave: dc.subjectTorque-
Palavras-chave: dc.subjectPilar protético-
Palavras-chave: dc.subjectPrótese implantossuportada-
Palavras-chave: dc.subjectPrótese dentária fixada por implante-
Palavras-chave: dc.subjectImplante dentário endoósseo-
Palavras-chave: dc.subjectReabilitação bucal-
Palavras-chave: dc.subjectMorse Cone-
Palavras-chave: dc.subjectTorque-
Palavras-chave: dc.subjectPilar-
Palavras-chave: dc.subjectImplant-supported prostheses-
Título: dc.titleDiscrepância vertical no posicionamento de pilares cone morse submetidos à diferentes forças de torque-
Título: dc.titleVertical discrepancy in height of cone morse pillars submitted to different torque forces-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.