Medida do diâmetro corneano em recém-nascidos de baixo risco

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorBarbosa, Adauto Dutra Moraes-
Autor(es): dc.contributorBueno, Arnaldo Costa-
Autor(es): dc.contributorLima, Luiz Claudio Santos de Souza-
Autor(es): dc.contributorLima, Gláucia Macedo de-
Autor(es): dc.contributorOrtiz Sobrinho, Cristina-
Autor(es): dc.contributorhttp://lattes.cnpq.br/1435162823879092-
Autor(es): dc.contributorhttp://lattes.cnpq.br/4193300724001794-
Autor(es): dc.contributorhttp://lattes.cnpq.br/3246791895201559-
Autor(es): dc.contributorhttp://lattes.cnpq.br/5757189767887416-
Autor(es): dc.contributorhttp://lattes.cnpq.br/6005132256904669-
Autor(es): dc.contributorhttp://lattes.cnpq.br/1146001952609219-
Autor(es): dc.creatorSousa, Isabela Vieira de-
Data de aceite: dc.date.accessioned2024-07-11T17:35:39Z-
Data de disponibilização: dc.date.available2024-07-11T17:35:39Z-
Data de envio: dc.date.issued2019-05-28-
Data de envio: dc.date.issued2019-05-28-
Data de envio: dc.date.issued2018-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/9711-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/753452-
Descrição: dc.descriptionIntrodução: Doenças que cursam com alterações no diâmetro corneano (DC) podem causar cegueira na infância. A medida do DC é importante para fins diagnósticos e terapêuticos dessas doenças. Objetivos: Estimar a medida do DC em recém-nascidos de baixo risco (RNBR) com relação à idade gestacional (IG), ao peso de nascimento (PN) e ao perímetro cefálico (PC), e analisar se existem diferenças nas medidas do DC, entre os olhos direito (OD) e esquerdo (OE) e entre os gêneros. Métodos: Estudo prospectivo e observacional, realizado em duas maternidades de Niterói-RJ, no período de outubro de 2016 a março de 2017, em RNBR, até a 2ª semana de vida. As medidas do DC horizontal (H) e vertical (V) e a oftalmoscopia direta foram realizadas em ambos os olhos. Utilizou-se o teste t de Student para verificar a diferença entre as médias dos valores do DC com relação ao OD e OE, e em relação ao gênero. A seguir, foi calculado o coeficiente de correlação (r) e o coeficiente de determinação (r2) para o modelo empregado e, através do cálculo das equações de regressão, foram estimados os valores dos DC e seus intervalos de confiança de 95%, que foram posteriormente extrapolados para cada valor de IG, PN e PC. Resultados: Foram incluídos no estudo 150 RNBR. As médias aritméticas e os desvios-padrão das medições em ambos os olhos foram: DCHOD 9,29±0,57mm e DCHOE 9,30±0,55mm (p =0,40), DCVOD 9,90±0,66mm e DCVOE 9,91±0,66mm (p=0,20). Não foram encontradas diferenças estatísticas entre os gêneros (DCHOD, p=0,30; DCHOE, p=0,28; DCVOD, p=0,20; DCVOE, p=0,18). Os valores de DC e o IC95% foram calculados e extrapolados para diferentes medidas de IG, PN e PC, sendo construídas tabelas relacionadas às medidas. Conclusão: As medidas de DC no RNBR não variam, em média, entre os OD e OE, e nem entre os gêneros. Os DC podem ser estimados de acordo com as medidas de IG, PN e PC encontradas.-
Descrição: dc.descriptionIntroduction: Diseases that occur with changes in corneal diameter (CD) can cause blindness in childhood. The measurement of CD is important for the diagnostic and therapeutic purposes of these diseases. Objectives: To estimate the CD measurement of low risk newborns in relation to gestational age (GA), birth weight (BW) and cephalic perimeter (CP), and to analyze whether there are differences in CD measurements, between right (RE) and left (LE) eyes and between genders. Methods: Prospective and observational study performed in two maternity hospitals in Niterói-RJ, from October 2016 to March 2017, in low risk newborns (LRNB), until the 2nd week of life. Horizontal (H) and vertical (V) CD measurements and direct ophthalmoscopy were performed in both eyes. The Student's t-test was used to verify the difference between the means of the CD values in relation to RE and LE, and in relation to gender. The correlation coefficient (r) and the coefficient of determination (r2) were then calculated for the model used and, through the calculation of the regression equations, the values of the CDs and their 95% confidence intervals (CI95%) were estimated, subsequently extrapolated for each value of BA, BW and CP. Results: 150 LRNBs were included in the study. The arithmetic means and standard deviations of the measurements in both eyes were: REHCD 9.29 ± 0.57mm and LEHCD 9.30 ± 0.55mm (p = 0.40), REVCD 9.90 ± 0.66mm and LEVCD 9.91 ± 0.66mm (p = 0.20). No statistical differences were found between the genders (REHCD, p = 0.30, LEHCD, p = 0.28, REVCD, p = 0.20, LEVCD, p = 0.18). The values of CD and CI95% were calculated and extrapolated to different measures of GA, BW and CP, and tables related to measurements were constructed. Conclusion: The measures of CD in LRNB do not vary, on average, between RE and LE, nor between the genders. The CDs can be estimated according to the measures of GA, BW and CP.-
Descrição: dc.description68f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectRecém-nascido-
Palavras-chave: dc.subjectDiâmetro-
Palavras-chave: dc.subjectCórnea-
Palavras-chave: dc.subjectIdade gestacional-
Palavras-chave: dc.subjectPeso ao nascimento-
Palavras-chave: dc.subjectPerímetro cefálico-
Palavras-chave: dc.subjectRecém-nascido-
Palavras-chave: dc.subjectCórnea-
Palavras-chave: dc.subjectGravidez-
Palavras-chave: dc.subjectPeso ao nascer-
Palavras-chave: dc.subjectCefalometria-
Palavras-chave: dc.subjectNewborn-
Palavras-chave: dc.subjectDiameter-
Palavras-chave: dc.subjectCornea-
Palavras-chave: dc.subjectGestational age-
Palavras-chave: dc.subjectBirth weight-
Palavras-chave: dc.subjectCephalic perimeter-
Título: dc.titleMedida do diâmetro corneano em recém-nascidos de baixo risco-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.