Descrição: dc.descriptionO risco de falhar um riser pode ser alto se não for previamente planejado uma estratégia de manutenção bem definida, caso falhe pode ocasionar acidentes, prejuízos econômicos, danos as pessoas e ao meio ambiente. Portanto, o presente trabalho tem como objetivo analisar um trecho de um riser de aço API 5L-B em operação, e dessa forma propor um planejamento de inspeção mais adequado e eficaz. Para isso, foi feito uma busca na literatura sobre o assunto em questão e uma coleta de dados técnica foi feita, a fim de compreender melhor a operação do riser. O riser em estudo está submetido a fadiga com defeitos de corrosão, sendo esta a base para a análise. A partir disso, foi feito uma apresentação dos métodos mais convencionais para estimar a fadiga do riser, caracterizando os níveis de confiabilidade e os parâmetros que são levados em consideração. Foi elaborado um exemplo de barra fixa para demonstrar o método FORM (Frist Order Reliability Method), para demonstração de como seria a aplicação do método, expondo o passo a passo para se chegar a probabilidade de falha. Para desenvolvimento da probabilidade de falha do riser foi utilizado o software COMREL, além disso o software forneceu os gráficos de confiabilidade e custo associado a inspeção. Aplicando no estudo de um caso de trecho de riser com defeito de corrosão abordado neste trabalho, foram gerados os dados específicos do riser através do ANSYS, com estes dados foi possível prosseguir para a análise mista S-N / MF onde foi possível determinar a tensão máxima do defeito de 92,29Mpa. A partir deste valor e de outros gerados e coletados, foi aplicado o método FORM com auxílio do COMREL para obtenção do nível de confiabilidade mínima, no valor de 3,24, validado pela curva de custo associado. Portanto, conclui-se que o valor obtido de 15 anos de vida útil, através do método FORM, em relação ao valor de 9 anos do método determinístico coletado da literatura, representa um ganho de 66% de vida útil. Foi gerado um algoritmo para este caso específico que poderá auxiliar em estudos futuros similares a este caso.-
Descrição: dc.descriptionThe risk of failure of a riser may be high if a well-defined maintenance strategy is not planned, failure to do so could lead to accidents, economic damage, injury to people and the environment. Therefore, the present work aims at analysing an excerpt from an API 5L-B steel production riser in operation, to propose a more adequate and efficient inspection planning. For this, a search was made in the literature on the subject in question and a technical data collection was made in order to better understand the operation of the riser. The studied riser is subjected to fatigue with corrosion defects, which is the basis for the analysis. From this, a presentation of the more conventional methods to estimate the riser fatigue was made, characterizing the levels of reliability and the parameters that are considered. An example of a fixed bar was developed to demonstrate the FORM (Frist Order Reliability Method) method, to demonstrate how the method would be applied, exposing the step by step to reach the probability of failure. To develop the probability of riser failure, the software COMREL was used, and the software provided the reliability and cost associated with inspection. Applying in the case study of a riser section with corrosion defect addressed in this work, the specific riser data were generated through the ANSYS, with this data it was possible to proceed to the SN / MF mixed analysis where it was possible to determine the maximum stress of the defect of 92.29Mpa. From this value and others generated and collected, the FORM method was applied with the help of COMREL to obtain the minimum reliability level, in the value of 3.24, validated by the associated cost curve. Therefore, it is concluded that the obtained value of 15 years of useful life, through the FORM method, in relation to the 9-year value of the deterministic method collected in the literature, represents a gain of 66% of useful life. An algorithm was generated for this specific case that could help in future studies like this case.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Federal Fluminense-
Publicador: dc.publisherRio das Ostras-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectRiser-
Palavras-chave: dc.subjectMétodo FORM-
Palavras-chave: dc.subjectCOMREL-
Palavras-chave: dc.subjectAnálise mista-
Palavras-chave: dc.subjectFadiga-
Palavras-chave: dc.subjectRiser-
Palavras-chave: dc.subjectAnalise de Risco-
Palavras-chave: dc.subjectRiser-
Palavras-chave: dc.subjectForm method-
Palavras-chave: dc.subjectCOMREL-
Palavras-chave: dc.subjectMixed analysis-
Palavras-chave: dc.subjectFatigue-