Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Quelhas, Osvaldo Luiz Gonçalves | - |
Autor(es): dc.contributor | Freitag, Alberto Eduardo Besser | - |
Autor(es): dc.contributor | Silva, Claudio Ribeiro da | - |
Autor(es): dc.creator | Coimbra, Emerson Antunes | - |
Data de aceite: dc.date.accessioned | 2024-07-11T17:31:33Z | - |
Data de disponibilização: dc.date.available | 2024-07-11T17:31:33Z | - |
Data de envio: dc.date.issued | 2020-03-06 | - |
Data de envio: dc.date.issued | 2020-03-06 | - |
Data de envio: dc.date.issued | 2017 | - |
Fonte completa do material: dc.identifier | https://app.uff.br/riuff/handle/1/13013 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.22409/PSG.2017.mp.05250661793 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/752081 | - |
Descrição: dc.description | A pesquisa avaliou os benefícios, em termos de ecoeficiência, da virtualização de TI do data center principal da Comissão Nacional de Energia Nuclear (CNEN). O índice de ecoeficiência escolhido foi o consumo de energia dos servidores. A pesquisa quantificou os servidores data center da CNEN, e através da exploração, identificou os servidores tradicionais, os servidores do cluster de virtualização, assim como suas respectivas máquinas virtuais. O consumo de energia dos servidores foi estimado com auxílio da ferramenta “Cost comparison toolkit: Calculating server power usage”. Os resultados mostram que todos os servidores analisados possuem baixo uso de processamento; que o cluster de virtualização da CNEN opera com excesso de recursos em uma escala que permitiria o desligamento de dois servidores sem comprometer o funcionamento do cluster; que um único servidor do cluster já é suficiente para abrigar todos os servidores não virtualizados em termos de processamento e memória. A pesquisa conclui que a virtualização dos servidores tradicionais é o melhor caminho para a CNEN conseguir uma redução do consumo de energia do seu data center e que o cluster de virtualização está desperdiçando energia, pois opera de forma subutilizada. Essa pesquisa contribui para um olhar mais profundo sobre a virtualização como alternativa para administração de data centers na administração pública. | - |
Descrição: dc.description | The survey evaluated the benefits, in terms of eco-efficiency, of IT virtualization from the main data center of the National Nuclear Energy Commission (CNEN). The eco-efficiency index chosen was the energy consumption of servers. The survey quantified CNEN's data center servers, and through exploration, identified the traditional servers, virtualization cluster servers, as well their respective virtual machines. The energy consumption of the servers was estimated using the tool "Cost comparison toolkit: Calculating server power usage". The results show that all analyzed servers have low processing usage; the virtualization cluster of CNEN operates with excess resources on a scale that would allow the shutdown of two servers without compromising the operation of the cluster; a single cluster server is enough to house all non-virtualized servers in terms of processing and memory. The survey concludes that virtualization of traditional servers is the best way for CNEN to achieve a reduction in the energy consumption of its data center and that the virtualization cluster is wasting energy because it operates underutilized. This research contributes to a deeper look at virtualization as an alternative to data center management in public administration. | - |
Descrição: dc.description | 64 p. | - |
Formato: dc.format | application/pdf | - |
Idioma: dc.language | pt_BR | - |
Publicador: dc.publisher | Niterói | - |
Direitos: dc.rights | openAccess | - |
Direitos: dc.rights | CC-BY-SA | - |
Palavras-chave: dc.subject | Virtualização | - |
Palavras-chave: dc.subject | Ecoeficiência | - |
Palavras-chave: dc.subject | sustentabilidade | - |
Palavras-chave: dc.subject | TI verde | - |
Palavras-chave: dc.subject | Desenvolvimento sustentável | - |
Palavras-chave: dc.subject | Ecoeficiência | - |
Palavras-chave: dc.subject | CNEN | - |
Palavras-chave: dc.subject | Virtualization | - |
Palavras-chave: dc.subject | Eco-efficiency | - |
Palavras-chave: dc.subject | Sustainability | - |
Palavras-chave: dc.subject | Green IT | - |
Título: dc.title | Desenvolvimento de solução ecoeficiente para data center | - |
Título: dc.title | Development of eco-efficient data center solution | - |
Tipo de arquivo: dc.type | Dissertação | - |
Aparece nas coleções: | Repositório Institucional da Universidade Federal Fluminense - RiUFF |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: