ARLA 32 : Otimização do processo de análise de qualidade em um laboratório

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorMaia, Mônica Pinto-
Autor(es): dc.contributorFernandes, Caio Machado-
Autor(es): dc.contributorFerreira, Karoline Kaiser-
Autor(es): dc.contributorde Oliveira, Alexandre Campos-
Autor(es): dc.contributorMaia, Monica Pinto-
Autor(es): dc.contributorOliveira, Alexandre Campos de-
Autor(es): dc.contributorFernandes, Caio Machado-
Autor(es): dc.contributorFerreira, Karoline Kaiser-
Autor(es): dc.creatorKeller, Vitor Gimenez Leite-
Data de aceite: dc.date.accessioned2024-07-11T17:28:33Z-
Data de disponibilização: dc.date.available2024-07-11T17:28:33Z-
Data de envio: dc.date.issued2022-02-23-
Data de envio: dc.date.issued2022-02-23-
Data de envio: dc.date.issued2022-02-14-
Fonte completa do material: dc.identifierhttp://app.uff.br/riuff/handle/1/24614-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/751057-
Descrição: dc.descriptionA emissão de óxidos de nitrogênio está aumentando anualmente, e por isso, vem sendo mais regulamentado, com limites de emissão mais restritivos. O ARLA 32 é uma solução de ureia, utilizada no sistema de redução catalítica seletiva, para reduzir a emissão desses óxidos em motores. É necessária a alta pureza de suas matérias-primas para que não ocorra danos no sistema. Visando o padrão de qualidade necessário para o funcionamento sem falhas e quebras do sistema, o ARLA 32 deve ser produzido seguindo rigorosos padrões de qualidade. Um laboratório que realiza estas análises, deve reportar a incerteza de medição dos ensaios como garantia de qualidade. Um estudo de caso foi realizado mediante a revisão das normas e construção de planilhas de medição de resultados e incertezas de acordo. Como resultado se observou a qualidade do trabalho realizado pela equipe de analistas do laboratório, uma vez que os testes utilizando os dados de limite das especificações nas planilhas desenvolvidas mostraram resultados de incerteza satisfatório, de acordo com a avaliação interna, além da redução significativa dos valores de incertezas dos ensaios, chegando a caso de redução de 28,6% para 1,2% de incerteza em relação ao resultado da medição-
Descrição: dc.descriptionThe emission of nitrogen oxides is increasing annually, and therefore, it has been more regulated, with more restrictive emission limits. ARLA 32 is a urea solution used in the selective catalytic reduction system to reduce the emission of these oxides in engines. The high purity of its raw materials is required so that no damage to the system occurs. Aiming at the quality standard necessary for the system to function without failures and breakdowns, the ARLA 32 must be produced following strict quality standards. A laboratory that performs these analyses, must report the measurement uncertainty of the tests as a guarantee of quality. A case study was carried out by reviewing the standards and building spreadsheets to measure results and uncertainties accordingly. As a result, the quality of the work carried out by the team of laboratory analysts was observed, since the tests using the specification limit data in the developed spreadsheets showed satisfactory uncertainty results, according to the internal evaluation, in addition to the significant reduction of the values of test uncertainties, reaching a reduction from 28.6% to 1.2% of uncertainty in relation to the measurement result-
Descrição: dc.description91 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherNiterói-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectARLA 32-
Palavras-chave: dc.subjectqualidade-
Palavras-chave: dc.subjectgrau de incerteza-
Palavras-chave: dc.subjectÓxido de nitrogênio-
Palavras-chave: dc.subjectQualidade do produto-
Palavras-chave: dc.subjectEngenharia química-
Palavras-chave: dc.subjectAUS 32-
Palavras-chave: dc.subjectquality-
Palavras-chave: dc.subjectuncertainty-
Título: dc.titleARLA 32 : Otimização do processo de análise de qualidade em um laboratório-
Tipo de arquivo: dc.typeTrabalho de conclusão de curso-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.