Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Santos, Paulo Acioly Marques dos | - |
Autor(es): dc.contributor | Nunes, Luiz Carlos da Silva | - |
Autor(es): dc.contributor | Souza, Carlos Eduardo Rodrigues de | - |
Autor(es): dc.creator | Freire Junior, Rosembergue Brasileiro da Rocha | - |
Data de aceite: dc.date.accessioned | 2024-07-11T17:28:00Z | - |
Data de disponibilização: dc.date.available | 2024-07-11T17:28:00Z | - |
Data de envio: dc.date.issued | 2019-09-26 | - |
Data de envio: dc.date.issued | 2019-09-26 | - |
Data de envio: dc.date.issued | 2012 | - |
Fonte completa do material: dc.identifier | https://app.uff.br/riuff/handle/1/11487 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/750865 | - |
Descrição: dc.description | No presente trabalho, foi desenvolvido um microscópio holográfico digital para analisar amostras biológicas. A microscopia holográfica digital (MHD) é baseada nos conceitos de holografia digital. Na holografia digital, o padrão de interferência é gerado pelos feixe objeto e o feixe de referência, este padrão de interferência é gravado num sensor de imagens CCD (Dispositivo de Carga Acoplada) como meio holográfico. Outra característica importante da holografia digital é o processo de reconstrução. Neste caso utilizamos programas específicos de computador, em geral baseados em conceitos clássicos de difração, que é usado para reconstruir a imagem digital do objeto. Neste processo temos a informação da intensidade e da fase do objeto. A MHD foi implementada com a introdução de um microscópio em um dos braços do interferômetro de Mach-Zender. O padrão de interferência gerado pelo feixe de referência e a imagem ampliada do objeto produzida pela objetiva de microscópio, é gravado no sensor CCD. A técnica mais utilizada para reconstruir a imagem do objeto é o Método de Dupla Propagação. Amostras biológicas foram utilizadas para testar o desempenho do MHD, essas imagens obtidas foram comparadas com as imagens de um microscópio convencional. Com a informação não só da intensidade, mas também da fase, é possível obter e medir com alta precisão a topografia do objeto | - |
Descrição: dc.description | In the present work a digital holographic microscope was developed to analyze biological samples. The digital holographic microscopy (MDH) is based on the concepts of digital holography. In the digital holography the interference pattern is generated by the object beam and reference beam mixed and recorded in a CCD (ChargeCoupled Device) sensor. Another significant characteristic of digital holography is image reconstruction process. In this case, computer specific programs, in general based on classical diffraction concepts, is used to reconstruct the object image digitally. This process turns available not only intensity distribution of the image, but also the phase. The MDH has been implemented introducing a microscope in one arm of a Mach-Zender interferometer. The interference pattern between the reference beam and the magnified image of the object produced by the objective lens was recorded in the CCD sensor. The most widely used technique to reconstruct the image of the object is the Double Propagation Method. Biological samples were used to test the DHM performance. The images obtained by the DHM and by the conventional microscope were compared. With the information not only intensity but also the phase, it is possible to obtain and measure with high precision the topography of the object | - |
Formato: dc.format | application/pdf | - |
Idioma: dc.language | pt_BR | - |
Direitos: dc.rights | openAccess | - |
Direitos: dc.rights | openAccess | - |
Direitos: dc.rights | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | - |
Direitos: dc.rights | CC-BY-SA | - |
Palavras-chave: dc.subject | Holografia | - |
Palavras-chave: dc.subject | Microscopia | - |
Palavras-chave: dc.subject | Microscopia digital | - |
Palavras-chave: dc.subject | Interferometria | - |
Palavras-chave: dc.subject | Holografia | - |
Palavras-chave: dc.subject | Microscopia | - |
Palavras-chave: dc.subject | Interferometria | - |
Palavras-chave: dc.subject | Holography | - |
Palavras-chave: dc.subject | Microscopy | - |
Palavras-chave: dc.subject | Digital microscopy | - |
Palavras-chave: dc.subject | Interferometry | - |
Título: dc.title | Introdução à microscopia holográfica digital | - |
Tipo de arquivo: dc.type | Trabalho de conclusão de curso | - |
Aparece nas coleções: | Repositório Institucional da Universidade Federal Fluminense - RiUFF |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: