Descrição: dc.descriptionEste trabalho baseou-se no manual de ar comprimido, proposto pelo PROCEL (2008) e Pacheco (2018), que propõem metodologias para estimativa e cálculo de eficiência energética em compressores, através do levantamento de parâmetros medidos em campo, durante o funcionamento das máquinas, como temperaturas de admissão e descarga do ar, e pressões de entrada e saída das máquinas, intensidades de correntes elétricas, etc. Também foi realizado neste trabalho visando resultados mais específicos quanto a perdas por vazamentos o método proposto por Freitas (2017), onde é necessários conhecer volume do reservatório de ar, tempo decorrente entre carga e alívio dos compressores, assim como suas pressões de trabalho. O método proposto para eficiência energética proposto pelo PROCEL (2008) apresenta resultados com valores inferiores quando comparados ao proposto por Pacheco (2018), essa diferença é explicada devido a suas equações serem mais sensíveis a entrada dos parâmetros. No tocante a perdas de ar no sistema de ar comprimido, o método proposto por Freitas (2017) enquadra o empreendimento em desacordo com os valores máximos permitidos para fugas de ar comprimido, de acordo com a idade da planta e seu estado de conservação.-
Descrição: dc.descriptionThis work was based on the manual of compressed air, proposed by PROCEL (2008) and Pacheco (2018), which propose methodologies for estimation and calculation of energy efficiency in compressors, through the survey of parameters measured in the field during the operation of the machines , such as air inlet and outlet temperatures, and machine inlet and outlet pressures, electric currents, etc. The method proposed by Freitas (2017), where it is necessary to know the volume of the air reservoir, the time between loading and relief of the compressors, as well as their working pressures, was also performed in order to obtain more specific results regarding leakage losses. The proposed method for energy efficiency proposed by PROCEL (2008) presents results with lower values when compared to that proposed by Pacheco (2018), this difference is explained because its equations are more sensitive to the input of the parameters. With regard to air losses in the compressed air system, the method proposed by Freitas (2017) fits the project in disagreement with the maximum values allowed for compressed air leaks, according to the age of the plant and its conservation status.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherNiterói-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectRendimento-
Palavras-chave: dc.subjectVazamento-
Palavras-chave: dc.subjectEconomia-
Palavras-chave: dc.subjectEficiência energética-
Palavras-chave: dc.subjectAr comprimido-
Palavras-chave: dc.subjectYield-
Palavras-chave: dc.subjectLeakage-
Palavras-chave: dc.subjectEconomy-