Síntese, caracterização e aplicação de catalisadores à base de níquel e platina suportados em óxido de grafeno reduzido na oxidação do tolueno

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorSimões, Rita de Cássia Colman-
Autor(es): dc.contributorOliveira, Hugo Alvarenga-
Autor(es): dc.contributorAzevedo, Gustavo Dias-
Autor(es): dc.creatorRodrigues, Aron Seixas Terra-
Data de aceite: dc.date.accessioned2024-07-11T17:25:10Z-
Data de disponibilização: dc.date.available2024-07-11T17:25:10Z-
Data de envio: dc.date.issued2020-09-25-
Data de envio: dc.date.issued2020-09-25-
Data de envio: dc.date.issued2019-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/14983-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/749890-
Descrição: dc.descriptionO presente trabalho teve por objetivo sintetizar óxido de grafeno reduzido (OGR) a partir da oxidação do grafite pelo método de Hummers com subsequente processo de expansão e redução térmica. A impregnação úmida foi adotada como método para adição dos metais (níquel e platina) ao suporte (OGR). Tanto o suporte quanto os catalisadores foram caracterizados por diversas técnicas: difração de raios-X (DRX), espectroscopia RAMAN, espectroscopia no infravermelho por transformada de Fourier (FTIR), adsorção-dessorção de nitrogênio, análise termogravimétrica (ATG) e microscopia eletrônica de varredura (MEV). Os resultados do suporte mostraram a oxidação adequada do grafite e a formação do OGR e um aumento de 23 vezes na área especifica, sendo obtido um valor de 158 m²/g. Apesar da oxidação do grafite, os perfis de DRX mostraram que a síntese foi incompleta e o domínio do grafite pôde ser observado na estrutura final. Os catalisadores sintetizados apresentaram alteração na estrutura cristalina à adição do níquel e da platina. Houve uma redução na área específica dos catalisadores, uma vez que os valores apresentados pelos 1Pt/OGR e 10Ni/OGR foram de 31 e 77 m²/g. As micrografias por MEV permitiram observar as partículas metálicas sob a estrutura do suporte. Adicionalmente as imagens por EDS indicam a dispersão homogênea das partículas de níquel na estrutura do material enquanto as partículas de platina se concentraram nas folhas de OGR. Os catalisadores foram avaliados na oxidação catalítica do tolueno a 400°C, empregando uma mistura contendo O2, tolueno e He (20% de O2, 1000 ppm de tolueno e He para completar o balanço) a uma vazão total de 150 ml/min. Com relação a eliminação do tolueno na mistura, o catalisador 1Pt/OGR apresentou melhor desempenho, eliminando 99,13% do tolueno, enquanto o catalisador 10Ni/OGR eliminou 55,13%-
Descrição: dc.descriptionCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES-
Descrição: dc.descriptionThe present work aimed to synthesize reduced graphene oxide (RGO) from graphite oxidation by the Hummer’s method with subsequent thermal expansion and reduction process. The wet impregnation was adopted as a method for adding the metals (nickel and platinum) to the support (OGR). Both the support and the catalysts were characterized for several techniques: X-ray diffraction (XRD), RAMAN spectroscopy, Fourier transform infrared spectroscopy (FTIR), nitrogen adsorption-desorption, thermogravimetric analysis (TGA) and scanning electron microscopy (SEM). The support results showed the correct graphite oxidation and the RGO formation and an increase of 23 times in the surface area obtaining 158 m²/g. Despite of the graphite oxidation, the XRD patterns showed that the synthesis was incomplete and the graphite domain could be observed in the final structure. The catalysts synthetized exhibited alteration in the crystalline phases after the nickel and platinum addition. There was a reduction on the catalysts specific surface area, the values exhibited for 1Pt/OGR and 10Ni/OGR were 31, 32 e 77, 44 m²/g. The SEM images allowed observing the metallic particles under the support structure. Additionally, the EDS images indicated the nickel homogeneous dispersion under the material structure while the platinum particles showed concentrated particles above the RGO sheets. The catalytic tests were performed at 400°C, under a mixture of O2, toluene and He (20% O2, 1000 ppm toluene and He to complete the balance) with a total flow of 150 ml/min. Regarding the toluene removing in the mixture, the 1Pt/OGR catalyst exhibited better performance by eliminating 99,13% of toluene while 10Ni/OGR catalyst removed 55,13%-
Descrição: dc.description127 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectCOVs-
Palavras-chave: dc.subjectÓxido de grafeno reduzido-
Palavras-chave: dc.subjectCatalisador de níquel-
Palavras-chave: dc.subjectCatalisador de platina-
Palavras-chave: dc.subjectOxidação do tolueno-
Palavras-chave: dc.subjectOxidação-
Palavras-chave: dc.subjectComposto Orgânico Volátil-
Palavras-chave: dc.subjectCatalisador-
Palavras-chave: dc.subjectVOCs-
Palavras-chave: dc.subjectReduced graphene oxide-
Palavras-chave: dc.subjectNickel catalyst-
Palavras-chave: dc.subjectPlatinum catalyst-
Palavras-chave: dc.subjectToluene oxidation-
Título: dc.titleSíntese, caracterização e aplicação de catalisadores à base de níquel e platina suportados em óxido de grafeno reduzido na oxidação do tolueno-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.