Análise do desempenho acústico de sistemas de fechamentos industrializados para edificações.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorRibas, Rovadávia Aline de Jesus-
Autor(es): dc.contributorPaula, Geraldo Donizetti de-
Autor(es): dc.contributorRibas, Rovadávia Aline de Jesus-
Autor(es): dc.contributorPaula, Geraldo Donizetti de-
Autor(es): dc.contributorSouza, Henor Artur de-
Autor(es): dc.contributorRusso, Mário Luís Cabello-
Autor(es): dc.creatorMagalhães, Paulo Henrique Silva-
Data de aceite: dc.date.accessioned2022-02-21T19:59:25Z-
Data de disponibilização: dc.date.available2022-02-21T19:59:25Z-
Data de envio: dc.date.issued2020-12-04-
Data de envio: dc.date.issued2020-12-04-
Data de envio: dc.date.issued2019-
Fonte completa do material: dc.identifierhttp://www.repositorio.ufop.br/handle/123456789/13013-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/650830-
Descrição: dc.descriptionPrograma de Pós-Graduação em Construção Metálica. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto.-
Descrição: dc.descriptionA inserção de novos métodos de execução e materiais no cotidiano da construção civil proporciona a melhora da qualidade de vida e o conforto dos usuários de edificações, possibilitada a partir de estudos e testes. Nesse contexto, o objetivo desse trabalho foi analisar o desempenho acústico de sistemas de fechamentos industrializados aplicados a edificações, visando a adequação e otimização do conforto acústico para os usuários. O desempenho acústico dos sistemas de fechamentos foi realizado por meio de uma análise computacional, avaliando-se a Perda na Transmissão Sonora (PT) que ocorre através dos fechamentos. Os materiais avaliados foram: painéis de placa cimentícia (PLC), gesso acartonado (GEA), pré-moldado de concreto (PMC), concreto celular autoclavado (CCA), poliestireno expandido (EPS), vidro (VDO), placa de tiras de madeiras orientadas - oriented strand board (OSB) e alvenaria de tijolo cerâmico (ATC). As análises foram feitas com base em um método gráfico em painéis simples e duplos aplicando-se um modelo computacional. De acordo com os resultados das análises, pode-se verificar que composições de materiais dos fechamentos apresentaram os maiores valores de perda na transmissão sonora. Em painéis simples, a alvenaria de tijolo cerâmico (ATC) se destacou mediante o concreto celular autoclavado (CCA) e vidro (VDO), apresentando resultados inferiores de PT apenas quando comparada ao pré-moldado de concreto (PMC). Em painéis duplos, quando comparados com a ATC, o poliestireno expandido (EPS) obteve a maior PT, seguido por placa cimentícia (PLC), gesso acartonado (GEA), placa de tiras de madeiras orientadas combinado com gesso acartonado (OSB-GEA) e painel de tiras de madeiras orientadas (OSB).-
Descrição: dc.descriptionThe insertion of new execution methods and materials in the daily construction provides a better quality of life and comfort for users, enabled by studies and tests. In this context, the goal of this work was to study the acoustic performance of industrialized closure systems applied to buildings, aiming to adequate and optimize acoustic comfort for users. The acoustic performance study of the closure systems was made through computational analysis, evaluating the Sound Transmission Loss (TL) that occurs through the closures. The materials evaluated were cementitious board (PLC), plasterboard (GEA), massive precast concrete (PMC), aerated autoclave concrete (CCA), expanded polystyrene panels (EPS), glass (VDO), oriented strand boards (OSB) and masonry (ATC). The analyses were made based on a graphical method in simple and double panels using a computational model. According to the results, it was possible to verify that closure systems with material compositions presented the highest transmission loss values. In simple panels, masonry (ATC) stood out when compared to aerated autoclave concrete (CCA) and glass (VDO), presenting lower TL results only when compared to the massive precast concrete (PMC). In double panels, when compared to the ATC, the expanded polystyrene panels (EPS) obtained the highest TL, followed by the cementitious board (PLC), the plasterboard (GEA), oriented strand boards combined with plasterboard (OSB-GEA) and oriented strand boards (OSB).-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsaberto-
Direitos: dc.rightsAutorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 30/06/2020 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais nem a adaptação.-
Palavras-chave: dc.subjectSistema de fechamento-
Palavras-chave: dc.subjectEstrutura em aço-
Palavras-chave: dc.subjectDesempenho acústico-
Título: dc.titleAnálise do desempenho acústico de sistemas de fechamentos industrializados para edificações.-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - UFOP

Não existem arquivos associados a este item.