Remoção da interferência de 60 hz no sinal de ECG usando filtro notch digital.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorBarbosa, Gustavo Vinícius Duarte-
Autor(es): dc.creatorBaracho, Francisco Ricardo Abrantes Couy-
Autor(es): dc.creatorSantos, José Ronaldo Tavares-
Autor(es): dc.creatorDamião, Laerty João dos Santos-
Data de aceite: dc.date.accessioned2022-02-21T19:57:46Z-
Data de disponibilização: dc.date.available2022-02-21T19:57:46Z-
Data de envio: dc.date.issued2020-10-23-
Data de envio: dc.date.issued2020-10-23-
Data de envio: dc.date.issued2019-
Fonte completa do material: dc.identifierhttp://www.repositorio.ufop.br/handle/123456789/12879-
Fonte completa do material: dc.identifierhttps://doi.org/10.34117/bjdv5n7-082-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/650250-
Descrição: dc.descriptionA interferência de 60 Hz AC pode ser um problema em qualquer situação de medição de biopotencial. A fonte dessa interferência é o potencial AC da rede de alimentação de energia elétrica que está inevitavelmente presente em qualquer situação clínica, ou para iluminação do ambiente ou como fonte de suprimento dos equipamentos de medição. A interferência causada pela rede elétrica, em 60 Hz, pode ser difícil de detectar visualmente em sinais tendo formas de onda não-regulares, como o EEG ou o EMG. Não obstante, a interferência é facilmente visível quando presente em sinais com formas de onda bem definidas, como é o caso do sinal de ECG (Eletrocardiograma). Em todo caso, o espectro de potência do sinal deve fornecer uma indicação clara da presença da interferência da rede como um impulso em 60 Hz. Os harmônicos, caso presentes, aparecem como impulsos adicionais em múltiplos inteiros da frequência fundamental. Neste trabalho é demonstrada uma técnica de filtragem, empregando um filtro “Notch” digital, o qual remove o artefato de 60 Hz do sinal de ECG, aumentando a confiabilidade do diagnóstico clínico a partir da interpretação do mesmo.-
Descrição: dc.description60 Hz AC interference can be a problem in any biopotential measurement situation. The source of such interference is the AC potential of the electrical power supply network that is inevitably present in any clinical situation, either for lighting the environment or as a source of supply for the measuring equipment. Electrical interference at 60 Hz can be difficult to detect visually on signals having non-regular waveforms such as EEG or EMG. Nevertheless, the interference is easily visible when present in signals with well-defined waveforms, such as the ECG (Electrocardiogram) signal. In any case, the power spectrum of the signal shall provide a clear indication of the presence of the network interference as a 60 Hz pulse. The harmonics, if present, appear as additional pulses in integral multiples of the fundamental frequency. In this work, a filtering technique is demonstrated, using a digital Notch filter, which removes the 60 Hz artifact from the ECG signal, increasing the reliability of the clinical diagnosis from its interpretation.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsaberto-
Direitos: dc.rightsO periódico Brazilian Journal of Development permite o depósito das versões pré-print e pós-print de um artigo. Permite remixagem, adaptação e nova criação a partir da obra para fins não comerciais desde que seja atribuído o crédito ao autor (CC BY-NC). Fonte: Diadorim <http://diadorim.ibict.br/handle/1/1253>. Acesso em: 18 maio 2020.-
Palavras-chave: dc.subjectAmplificador de ECG-
Palavras-chave: dc.subjectMATLAB-
Palavras-chave: dc.subjectInterferência eletromagnética-
Título: dc.titleRemoção da interferência de 60 hz no sinal de ECG usando filtro notch digital.-
Título: dc.titleRemoval of 60 Hz interference on the ECG signal using digital notch filter.-
Aparece nas coleções:Repositório Institucional - UFOP

Não existem arquivos associados a este item.