Usefulness of the second heart sound for predicting pulmonary hypertension in patients with interstitial lung disease

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorCobra, Sandra de Barros-
Autor(es): dc.creatorCardoso, Rayane Marques-
Autor(es): dc.creatorRodrigues, Marcelo Palmeira-
Data de aceite: dc.date.accessioned2021-10-14T18:21:09Z-
Data de disponibilização: dc.date.available2021-10-14T18:21:09Z-
Data de envio: dc.date.issued2017-12-07-
Data de envio: dc.date.issued2017-12-07-
Data de envio: dc.date.issued2016-01-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/30354-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1590/1516-3180.2015.00701207-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/629557-
Descrição: dc.descriptionHiperfonese de P2 tem sido considerada como achado valoroso no diagnóstico semiológico de hipertensão pulmonar (HP). O objetivo foi de avaliar a acurácia do componente pulmonar da segunda bulha cardíaca em predizer HP nos pacientes portadores de doenças intersticiais pulmonares. TIPO DE ESTUDO E LOCAL: Estudo transversal na Universidade de Brasília e Hospital de Base do Distrito Federal. MÉTODOS: Os sons cardíacos foram adquiridos com estetoscópio eletrônico e analisados por fonocardiografia. Os sinais clínicos sugestivos de HP, como B2 mais intensamente audível em área pulmonar que aórtica, P2 > A2 na área pulmonar e P2 presente em área mitral foram confrontados com parâmetros cardiográficos no exame de Doppler sugestivos de HP. Sensibilidade (S), especificidade (E), razões de verossimilhança positiva (RV+) e negativa (RV-) foram avaliados. RESULTADOS: Não houve correlação significativa entre amplitude de B2 e P2 e a PSAP (pressão sistólica arterial pulmonar) (P = 0,185 e 0,115; P = 0,13 e 0,34; respectivamente). A análise da presença de B2 mais intensa na área pulmonar que aórtica, quando comparada a todos os critérios sugestivos de HP, mostrou S = 60%; E = 22%; RV+ = 0,7; RV- = 1,7; enquanto P2 > A2 mostrou: S = 57%; E = 39%; RV+ = 0,9; RV- = 1,1; e P2 no foco mitral mostrou: S = 68%; E = 41%; RV+ = 1,1; RV- = 0,7. Todos os sinais juntos mostraram S = 50%; E = 56%. CONCLUSÃO: Os sinais semiológicos indicativos de HP apresentam baixos valores de especificidade e sensibilidade para diagnóstico clínico dessa comorbidade.-
Descrição: dc.descriptionP2 hyperphonesis is considered to be a valuable finding in semiological diagnoses of pulmonary hypertension (PH). The aim here was to evaluate the accuracy of the pulmonary component of second heart sounds for predicting PH in patients with interstitial lung disease. DESIGN AND SETTING: Cross-sectional study at the University of Brasilia and Hospital de Base do Distrito Federal. METHODS: Heart sounds were acquired using an electronic stethoscope and were analyzed using phonocardiography. Clinical signs suggestive of PH, such as second heart sound (S2) in pulmonary area louder than in aortic area; P2 > A2 in pulmonary area and P2 present in mitral area, were compared with Doppler echocardiographic parameters suggestive of PH. Sensitivity (S), specificity (Sp) and positive (LR+) and negative (LR-) likelihood ratios were evaluated. RESULTS: There was no significant correlation between S2 or P2 amplitude and PASP (pulmonary artery systolic pressure) (P = 0.185 and 0.115; P= 0.13 and 0.34, respectively). Higher S2 in pulmonary area than in aortic area, compared with all the criteria suggestive of PH, showed S = 60%, Sp= 22%; LR+ = 0.7; LR- = 1.7; while P2> A2 showed S= 57%, Sp = 39%; LR+ = 0.9; LR- = 1.1; and P2 in mitral area showed: S= 68%, Sp = 41%; LR+ = 1.1; LR- = 0.7. All these signals together showed: S= 50%, Sp = 56%. CONCLUSIONS: The semiological signs indicative of PH presented low sensitivity and specificity levels for clinically diagnosing this comorbidity.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languageen-
Publicador: dc.publisherAssociação Paulista de Medicina - APM-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsSao Paulo Medical Journal - This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0). Fonte: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-31802016000100034&lng=en&nrm=iso. Acesso em: 21 dez. 2017.-
Palavras-chave: dc.subjectHipertensão pulmonar-
Palavras-chave: dc.subjectPulmões - doenças-
Palavras-chave: dc.subjectCoração - sons-
Palavras-chave: dc.subjectEcocardiografia-
Palavras-chave: dc.subjectFonocardiografia-
Título: dc.titleUsefulness of the second heart sound for predicting pulmonary hypertension in patients with interstitial lung disease-
Título: dc.titleUtilidade da segunda bulha cardíaca na predição de hipertensão pulmonar em portadores de doenças intersticiais pulmonares-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.