Avaliação de distorções harmônicas e inter-harmônicas de um sistema de conversão de energia eólica com gerador síncrona

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorFerreira Filho, Anésio de Leles-
Autor(es): dc.creatorSilveira, João Pedro Carvalho-
Data de aceite: dc.date.accessioned2021-10-14T18:04:10Z-
Data de disponibilização: dc.date.available2021-10-14T18:04:10Z-
Data de envio: dc.date.issued2017-01-16-
Data de envio: dc.date.issued2017-01-16-
Data de envio: dc.date.issued2017-01-16-
Data de envio: dc.date.issued2016-07-29-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/22216-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.26512/2016.07.D.22216-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/622807-
Descrição: dc.descriptionDissertação (mestrado) — Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2016.-
Descrição: dc.descriptionA evolução do cenário energético mundial nas últimas décadas evidencia a ascensão tecnológica da geração eólica e o seu crescimento expressivo no contexto das fontes renováveis de energia. No entanto, devido às características de operação, os sistemas de conversão de energia eólica podem ser responsáveis pela geração de harmônicas e inter-harmônicas, ocasionando em impactos na qualidade da energia elétrica no ponto de acoplamento com a rede. De modo a viabilizar tais conexões, mantendo uma qualidade adequada, normas e recomendações como a IEC 61400-21, a IEC 61000-4-7 e a IEEE 519, atreladas às distorções na forma de onda, foram elaboradas. Para atender aos requisitos estabelecidos por estas normas, identifica-se a necessidade de se investigar e mitigar as distorções harmônicas e inter-harmônicas geradas pelos sistemas eólicos. Mediante às questões supramencionadas, surgiu a ideia de desenvolvimento deste trabalho que tem por finalidade analisar a relação das distorções harmônicas e inter-harmônicas com alguns dos fatores de operação de conversores back-to-back usualmente empregados em parques eólicos industriais, a saber: o tempo morto, a frequência de chaveamento e a tensão no barramento CC. Esta avaliação é executada por meio de simulações computacionais de um sistema eólico com gerador síncrono a imãs permanentes, abordando-se também a sua concepção laboratorial. Posto isso, entende-se que a principal contribuição da presente dissertação concentra-se na identificação dos fatores mais significativos na emissão das distorções na forma de onda.-
Descrição: dc.descriptionThe evolution of the world energy scenario in recent decades highlights the technological rise of wind power and its significant growth in the context of renewable energy sources. However, due to the operating characteristics, the wind power energy conversion systems might be responsible for the generation of harmonics and inter-harmonics, resulting in impacts on the power quality when connected to the power grid. In order to enable such connections, maintaining an adequate quality, standards such as the IEC 61400-21, IEC 61000-4-7 and IEEE 519, linked to distortions in the waveform, were elaborated. To meet the specifications required by these standards, a need to investigate and mitigate harmonic and inter-harmonic distortions generated by wind systems is identified. Through the above issues, came the idea of the development of this work which aims to analyze the relationship of the harmonic and inter-harmonic distortion with some of the back-to-back converter operating factors usually employed in industrial wind farms, namely: the dead time, the switching frequency and the voltage on the DC bus. This evaluation is performed by means of computer simulations of a wind system with permanent magnets synchronous generator, also covering up your laboratory design. That said, it is understood that the main contribution of this dissertation concentrated by identifying the most significant factors in the issue of distortions in the waveform.-
Formato: dc.formatapplication/pdf-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.-
Palavras-chave: dc.subjectEnergia - fontes alternativas-
Palavras-chave: dc.subjectQualidade da energia-
Palavras-chave: dc.subjectConversores de corrente elétrica-
Palavras-chave: dc.subjectEnergia eólica-
Palavras-chave: dc.subjectSistemas eólicos-
Título: dc.titleAvaliação de distorções harmônicas e inter-harmônicas de um sistema de conversão de energia eólica com gerador síncrona-
Título: dc.titleEvaluation of harmonics and inter-harmonics distortions on wind energy conversion system with synchronous generator-
Tipo de arquivo: dc.typelivro digital-