Estudo histomorfométrico da influência do diâmetro do orifício-piloto na interface entre o implante e o osso vertebral

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorFerreira, Graziela Nascimento-
Autor(es): dc.creatorShimano, Antônio Carlos-
Autor(es): dc.creatorMatheus, João Paulo Chiregatto-
Autor(es): dc.creatorFaria, Paulo Esteves Pinto-
Autor(es): dc.creatorSalata, Antonio-
Autor(es): dc.creatorDefino, Helton L. A.-
Data de aceite: dc.date.accessioned2021-10-14T17:24:18Z-
Data de disponibilização: dc.date.available2021-10-14T17:24:18Z-
Data de envio: dc.date.issued2012-12-10-
Data de envio: dc.date.issued2012-12-10-
Data de envio: dc.date.issued2008-08-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/11786-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1590/S0102-36162008000800006-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/607111-
Descrição: dc.descriptionTrabalho realizado no Laboratório de Bioengenharia do Departamento de Biomecânica, Medicina e Reabilitação do Aparelho Locomotor da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo USP Ribeirão Preto (SP), Brasil.-
Descrição: dc.descriptionOBJETIVO: Estudar as alterações agudas da interface entre os parafusos e o tecido ósseo vertebral, considerando o diâmetro do orifício-piloto em relação ao diâmetro interno do parafuso. MÉTODOS: O estudo foi realizado em carneiros e a segunda vértebra cervical selecionada para o estudo. Foram utilizados parafusos corticais de 3,5mm de diâmetro externo (2,4mm de diâmetro interno) e 14mm de comprimento. Foram formados quatro grupos experimentais: 1) orifício-piloto de 2,0mm e colocação do parafuso de 3,5mm; 2) orifício-piloto de 2,5mm e colocação do parafuso de 2,5mm; 3) orifício-piloto de 2mm sem colocação do parafuso; e 4) orifício-piloto de 2,5mm sem colocação do parafuso. RESULTADOS: O grupo 1 (orifício-piloto menor do que o diâmetro interno do parafuso) apresentou maior densidade óssea no interior da rosca do implante e maior densidade óssea na área em espelho do que o grupo 2 (orifício-piloto maior que o diâmetro interno do parafuso). A superfície de contato entre o tecido ósseo e o implante foi maior no grupo 2 em relação ao grupo 1. A comparação da densidade óssea na área em espelho entre os grupos com e sem implante (1 e 3) e (2 e 4) mostrou que a densidade óssea era maior nos grupos com o implante. Não foi observada diferença estatística entre as comparações dos grupos experimentais. CONCLUSÃO: A utilização de orifício-piloto de menor diâmetro em relação ao diâmetro interno do parafuso apresentou tendência a provocar maior compactação do osso ao redor do implante. _______________________________________________________________________________________ ABSTRACT-
Descrição: dc.descriptionOBJECTIVE: To study acute changes in the interface between screws and vertebral bone tissue, considering the pilot hole diameter in relation to the inner diameter of the screw. METHODS: The study was carried out in sheep, and the second cervical vertebra was selected for the study. Cortical screws were used, with 3.5 mm of external diameter (2.4 mm of inner diameter) and 14 mm in length. Four experimental groups were formed: 1 2.0 mm pilot hole and placement of 3.5 mm screw; 2 - 2.5 mm pilot whole and placement of 2.5 mm screw; 3 - 2 mm pilot hole with no screw placement; and 4 2.5 mm pilot whole with no screw placement. RESULTS: Group 1 (pilot hole smaller than the inner diameter of the screw) presented more bone density inside the implant thread and more bone density in the mirror area than group 2 (pilot hole larger than the inner diameter of the screw). The contact surface between bone tissue and the implant was larger in group 2 when compared to group 1. The comparison of bone density in the mirror area among the groups with and without screw placement (1 and 3) and (2 and 4) showed that bone density was greater in the groups with screw placement. No statistical differences were seen among the comparisons of the experimental groups. CONCLUSION: The use of a pilot hole with a smaller diameter than the inner diameter of the screw tended to cause more bone compaction around the screw.-
Formato: dc.formatapplication/pdf-
Publicador: dc.publisherSociedade Brasileira de Ortopedia e Traumatologia-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsRevista Brasileira de Ortopedia - Política: A RBO permite a reprodução total ou parcial de seu conteúdo, desde que mencionada a fonte. Fonte: http://www.scielo.br/revistas/rbort/paboutj.htm#003. Acesso em: 31 out. 2012.-
Palavras-chave: dc.subjectColuna vertebral-
Palavras-chave: dc.subjectFixadores internos-
Palavras-chave: dc.subjectParafusos ósseos (Ortopedia)-
Palavras-chave: dc.subjectDispositivos de fixação ortopédica-
Palavras-chave: dc.subjectOvino-
Título: dc.titleEstudo histomorfométrico da influência do diâmetro do orifício-piloto na interface entre o implante e o osso vertebral-
Título: dc.titleHistomorphometric study of the influence of the pilot hole diameter on the interface between implant and vertebral bone-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.