Evaluation of signal-to-background and Mg II/Mg I ratios as response for the optimization of rare earth elements determination by inductively coupled plasma optical emission spectrometry.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorSilva, Aline Kelly Guimarães-
Autor(es): dc.creatorLena, Jorge Carvalho de-
Autor(es): dc.creatorFroes, Roberta E. S.-
Autor(es): dc.creatorCosta, Leticia Malta-
Autor(es): dc.creatorNascentes, Clésia Cristina-
Data de aceite: dc.date.accessioned2019-11-06T13:35:41Z-
Data de disponibilização: dc.date.available2019-11-06T13:35:41Z-
Data de envio: dc.date.issued2015-12-10-
Data de envio: dc.date.issued2015-12-10-
Data de envio: dc.date.issued2012-
Fonte completa do material: dc.identifierhttp://www.repositorio.ufop.br/handle/123456789/5943-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/558942-
Descrição: dc.descriptionElementos terras raras (ETR) fazem parte de um grupo peculiar de elementos químicos e sua determinação em amostras geológicas é importante e complexa, devido às baixas concentrações e problemas com interferências espectrais e não espectrais. Neste trabalho, planejamentos experimentais foram utilizados para otimizar as condições operacionais de um espectrômetro de emissão óptica com plasma indutivamente acoplado (ICP OES) para a determinação de ETR. A razão entre o sinal analítico dos ETR e o sinal de fundo (SBR) e a razão Mg II/Mg I foram avaliadas como respostas na otimização. De acordo com os resultados obtidos, três diferentes condições de operação foram selecionadas e classificadas como robusta, semi-robusta e melhor SBR. Limites de detecção (LOD), SBR e desvio padrão relativo de medidas de uma solução do branco (DPRbranco) foram determinados. Na condição semi-robusta (potência de 1250 W e vazão do gás nebulizador de 0,90 L min−1) foram obtidos LOD e DPRbranco mais baixos que nas outras condições estabelecidas. ____________________________________________________________________________________-
Descrição: dc.descriptionABSTRACT: Rare earth elements (REEs) is a peculiar group of chemical elements. Their determination in geological samples is important and complex due to their low concentrations and problems with spectral and non-spectral interferences. Herein, the operating conditions of an inductively coupled plasma optical emission spectrometer were optimized for the determination of REEs using experimental designs. The signal-to-background ratio (SBR) of the REEs emission signals and the Mg II/Mg I line intensity ratio were evaluated as response functions. According to the results obtained, three different sets of operating conditions were selected and classified as robust, semi robust and best SBR conditions. Limits of detection (LOD), SBR and relative standard deviation of the blank solution (RSDblank) were determined. The semi-robust condition (RF power of 1250 W and nebulizer gas flow rate of 0.90 L min−1) exhibited lower LOD and RSDblank than others tested operating conditions.-
Idioma: dc.languageen-
Direitos: dc.rightsTodo o conteúdo do periódico Journal of the Brazilian Chemical Society, exceto onde identificado, está licenciado sob uma licença Creative Commons que permite copiar, distribuir e transmitir o trabalho em qualquer suporte ou formato desde que sejam citados o autor e o licenciante. Fonte: <http://www.scielo.br/scielo.php?script=sci_serial&pid=0103-5053&lng=en&nrm=iso>. Acesso em: 21 out. 2015.-
Palavras-chave: dc.subjectRare earth elements-
Palavras-chave: dc.subjectOptimization-
Título: dc.titleEvaluation of signal-to-background and Mg II/Mg I ratios as response for the optimization of rare earth elements determination by inductively coupled plasma optical emission spectrometry.-
Aparece nas coleções:Repositório Institucional - UFOP

Não existem arquivos associados a este item.