Projeto de aterramento para sistema monofilar com retorno pelo terra.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorBertolo, Humberto C.-
Autor(es): dc.creatorOliveira Filho, Delly-
Autor(es): dc.creatorPizziolo, Tarcísio de Assunção-
Autor(es): dc.creatorRodrigues, Denilson Eduardo-
Autor(es): dc.creatorMonteiro, Paulo Marcos de Barros-
Data de aceite: dc.date.accessioned2019-11-06T13:34:45Z-
Data de disponibilização: dc.date.available2019-11-06T13:34:45Z-
Data de envio: dc.date.issued2015-05-26-
Data de envio: dc.date.issued2015-05-26-
Data de envio: dc.date.issued2010-
Fonte completa do material: dc.identifierhttp://www.repositorio.ufop.br/handle/123456789/5535-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/558554-
Descrição: dc.descriptionEste trabalho apresenta o projeto de aterramento elétrico para Sistema Monofilar com Retorno pela Terra (MRT), em solicitações de baixas frequências, utilizando-se o método das imagens e considerando a simplificação do método dos potenciais constantes. Simulou-se o comportamento de três diferentes configurações de aterramento: hastes em triângulo, em quadrado vazio e para nove hastes, formando uma malha com quatro quadrados. A partir da simulação obtiveram-se o valor da resistência de aterramento para cada configuração e os potenciais gerados na superfície do solo. Com base nesses resultados foi possível comparar os valores tabelados para resistências mínimas, em função da potência do transformador, aplicados para diferentes concessionárias de energia que utilizam o Sistema MRT, com os valores calculados que mantêm os potenciais no solo em níveis seguros para seres humanos e animais. Os resultados mostraram que é possível utilizar aterramentos mais simples e mais baratos, pois os gradientes de tensões no solo se mantiveram em níveis seguros. ____________________________________________________________________-
Descrição: dc.descriptionABSTRACT: This work presents a grounding project for a Single Wire Earth Return (SWER) system in low frequency applications, through the use of the image method, a simplification of the constant potential method. The responses of three different grounding configurations were simulated: electrodes in triangular format, electrodes placed in the corners of a square and nine electrodes placed in the corners of a grid with four squares. With the mentioned simulation it was possible to calculate the ground resistance and the surface voltage of each configuration. Based on these results, it was possible to compare the values for minimal resistance, depending on the power of the transformer, applied to various power utilities that use the SWER system with the values that hold the potential in the soil at safe levels for human beings and animals. Results showed that it is possible to use simpler and cheaper grounding configurations due to the fact that the surface voltages were maintained at safe levels.-
Idioma: dc.languagept_BR-
Direitos: dc.rightsA Revista Brasileira de Engenharia Agrícola e Ambiental permite que o Repositório Institucional da Universidade Federal de Ouro Preto (UFOP) deposite uma cópia eletrônica dos artigos publicados por esse periódico em que ao menos um dos autores faça parte da comunidade cientifica da UFOP. Fonte: Licença concedida mediante preenchimento de formulário no dia 30 abr. 2015.-
Palavras-chave: dc.subjectEletrificação rural-
Palavras-chave: dc.subjectComportamento do aterramento-
Palavras-chave: dc.subjectRural electrification-
Palavras-chave: dc.subjectGrounding behavior-
Título: dc.titleProjeto de aterramento para sistema monofilar com retorno pelo terra.-
Aparece nas coleções:Repositório Institucional - UFOP

Não existem arquivos associados a este item.