Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.creator | Souza, Érica Silva | - |
Autor(es): dc.creator | Martins, Amarildo Otavio | - |
Autor(es): dc.creator | Fajardo, Humberto Vieira | - |
Autor(es): dc.creator | Probst, Luiz Fernando Dias | - |
Autor(es): dc.creator | Carasek, Eduardo | - |
Data de aceite: dc.date.accessioned | 2019-11-06T13:33:30Z | - |
Data de disponibilização: dc.date.available | 2019-11-06T13:33:30Z | - |
Data de envio: dc.date.issued | 2015-04-09 | - |
Data de envio: dc.date.issued | 2015-04-09 | - |
Data de envio: dc.date.issued | 2008 | - |
Fonte completa do material: dc.identifier | http://www.repositorio.ufop.br/handle/123456789/4963 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/558044 | - |
Descrição: dc.description | This paper presents the development of an on-line pre-concentration system to determine cadmium(II) in aqueous samples. The analyte was trapped in a mini-column filled with Al2O3 in the form of macro-spheres obtained by the mixture of Al(NO3)3•9H2Oaq and chitosan dissolved in acetic acid. The mixture was dropped into an NH4OH aqueous solution under rigorous agitation using a peristaltic pump, the macro-spheres were separated from alkaline solution and dried, and finally were submitted to thermal treatment. The pre-concentration system was linear between 1.0 and 100 _gL−1, with a linearity of 0.999, sensitivity of 3.58×10−3 L_g−1 and enrichment factor of 21.9. The limits of detection and quantification were 0.08 _gL−1 and 0.28 _gL−1, respectively. The repeatability was between 2.6 and 5.9%. Recovery tests were carried out with a real aqueous sample. | - |
Idioma: dc.language | en | - |
Direitos: dc.rights | O Periódico Journal of Hazardous Materials concede permissão para depósito deste artigo no Repositório Institucional da UFOP. Número da licença: 3580760578368. | - |
Palavras-chave: dc.subject | Alumina | - |
Palavras-chave: dc.subject | Pre-concentration | - |
Palavras-chave: dc.subject | Cadmium(II) | - |
Palavras-chave: dc.subject | Flame atomic absorption spectrometry | - |
Título: dc.title | Use of Al2O3 in an automated on-line pre-concentration system for determination of cadmium(II) by FAAS. | - |
Aparece nas coleções: | Repositório Institucional - UFOP |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: