Monitoramento de microcontaminantes orgânicos por métodos cromatográficos acoplados a espectrometria de massa e inorgânicos por fluorescência de pós-graduação em engenharia ambiental raios–x por reflexão total nas águas da Bacia do Rio Doce.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorAfonso, Robson José de Cássia Franco-
Autor(es): dc.creatorQuaresma, Amanda de Vasconcelos-
Data de aceite: dc.date.accessioned2019-11-06T13:32:33Z-
Data de disponibilização: dc.date.available2019-11-06T13:32:33Z-
Data de envio: dc.date.issued2015-03-10-
Data de envio: dc.date.issued2015-03-10-
Data de envio: dc.date.issued2014-
Fonte completa do material: dc.identifierhttp://www.repositorio.ufop.br/handle/123456789/4575-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/557639-
Descrição: dc.descriptionPrograma de Pós-Graduação em Engenharia Ambiental. PROÁGUA, Pró-Reitoria de Pesquisa e Pós Graduação, Universidade Federal de Ouro Preto.-
Descrição: dc.descriptionOs microcontaminantes orgânicos de preocupação emergente, juntamente com os elementos inorgânicos, constituem atualmente o foco de muitos órgãos internacionais de proteção ao meio ambiente e à saúde humana e animal. Estes compostos, mesmo em pequenas concentrações no ambiente, são capazes de provocar efeitos adversos tanto no homem quanto na vida animal. A preocupação com estas substâncias no meio aquático aumenta cada vez mais, pois as rotas de contaminação são diversas e as tecnologias utilizadas comumente para o tratamento de águas e efluentes nao são eficazes para eliminá-los. Os microcontaminantes orgânicos e elementos inorgânicos apresentam características físico-químicas distintas, podem estar presentes em concentrações reduzidas em amostras complexas nos compartimentos ambientais. Estas características apresentam desafios no desenvolvimento de métodos analíticos para a determinação simultânea. Assim, esse trabalho focou no desenvolvimento de métodos analíticos para a determinação simultânea de microcontaminantes orgânicos e elementos inorgânicos em amostras de águas superficiais. Foram desenvolvidos e validados métodos para a determinação de 29 microcontaminantes de preocupação emergentes, os quais incluíram fármacos, plastificantes, hormônios naturais e sintéticos e subprodutos da degradação de detergentes usando cromatografia em fase líquida (UPLC) e em fase gasosa (GC) acopladas à espectrometria de massas (MS). Também foi desenvolvido e validado procedimento para a determinação de 13 elementos inorgânicos por fluorescência de raios – X por reflexão total (TXRF). Os procedimentos para a determinação de microcontaminantes orgânicos envolveram a pré-concentração e clean-up das amostras por extração em fase sólida (SPE), com recuperações variando entre 3,16 a 99,41 %. Os extratos produzidos foram divididos em frações para as análises por GC-MS e UPLC-HRMS. Para as análises por GCMS uma das frações foi derivatizada usando 75% BSTFA/25% piridina. Para os compostos orgânicos analisados por GC-MS foram obtidos limites de detecção do método que variaram de 0,50 a 6,97 ng/L e para os compostos analisados por UPLC-HRMS os limites foram de 0,58 a 7,44 ng/L. Para os elementos inorgânicos, os limites de detecção do método foram de 38,50 μg/L para K, 26,67 μg/L para Ca, 11,70 μg/L para Ti, 6,88 μg/L para Cr, 5,47 μg/L para Mn, 4,22 μg/L para Fe, 2,88 μg/L para Ni, 2,62 μg/L para Cu, 2,33 μg/L para Zn, 1,85 μg/L para As, 1,56 μg/L para Br, 2,15 μg/L para Sr, e 22,94 μg/L para o Ba. Os procedimentos validados foram aplicados para o monitoramento destas substâncias e elementos, ao longo da bacia do rio Doce (Minas Gerais, Brasil) em seis campanhas trimestrais nos anos de 2012 e 2013. Os elementos As, Cr e Ni foram encontrados em várias amostras. Dentre os microcontaminantes orgânicos monitorados o 4-octilfenol foi o mais encontrado nas amostras (91 %), seguido da cafeína (81 %), naproxeno (79 %), cimetidina (77 %) e atenolol (76 %). Os microcontaminantes orgânicos menos encontrados foram metformina (1,5 %), miconazol (1,5 %), aciclovir (2,2 %) e bezafibrato (2,2 %). Os resultados dessas análises foram tratados por meio da análise das componentes principais e foi possível observar o perfil de contaminação das amostras coletadas e relacioná-lo com dados da qualidade das águas nos locais de coleta. ______________________________________________________________________________________________-
Descrição: dc.descriptionABSTRACT: The organic microcontaminants of emerging concern, as the inorganic elements, are currently the focus and concern of many international organitions for the protection of the environment and the health of humans and animals. Those compounds, even at small concentrations in the environment, are capable of causing adverse effects to human beings and biota. The concern with those substances in the aquatic environment increases everyday, because the routes of contamination are diverse and the technologies commonly used for treatment of wastewaters and waters are not efficient to eliminate them. The organic microcontaminants and inorganic elements present physical-chemical properties that are distinct, they can be present in lower concentrations in complex samples in the environmental compartments. Those characteristics present challenges in the development of analytical methods for their simultaneous determination. Therefore, this work was focused on the development of analytical methods for the simultaneous determination of organic microcontaminants and inorganic elements in surface water samples. Analytical methods using Ultra Performance Liquid Chromatography (UPLC) and Gas Chromatography (GC) coupled to the mass spectrometry (MS) for the determination of 29 organic microcontaminants of emergent concern were developed and validated. The compounds included pharmaceutical, plasticizers, detergent degradation by products, natural and synthetic hormones. A procedure for the determination of 13 inorganic elements by total reflection X-ray fluorescence (TXRF) was also developed and validated. The procedures for the determination of organic microcontaminants included the preconcentration and clean-up of the samples by solid phase extraction (SPE), with recoveries ranging from 3,16 to 99,41%. The extracts produced were divided in two fractions for GCMS and UPLC-HRMS analysis. For GC-MS analysis the fractions were derivatized using 75% BSTFA/25% pyridine. The methods limit of detection for the organic compounds analyzed by GC-MS varied from 0,50 to 6,97 ng/L; and for the compounds analyzed by UPLC-HRMS the limits of detection varied from 1,58 to 7,44 ng/L. The method limit of detection for inorganic elements analyzed by TXRF, were 38,50 μg/L for K, 26,67 μg/L for Ca, 17,33 μg/L for Ti, 6,88 μg/L for Cr, 5,47 μg/L for Mn, 4,22 μg/L for Fe, 2,88 μg/L for Ni, 2,62 μg/L for Cu, 2,33 μg/L for Zn, 1,85 μg/L for As, 1,56 μg/L for Br, 2,15 μg/L for Sr, and 22,94 μg/L for Ba. The validated procedures were applied to the monitoring of those substances, along the Rio Doce basin (Minas Gerais, Brazil), at six quarterly campaigns in the years of 2012 and 2013. The toxic elements As, Cr and Ni were found in some samples. Among the monitored organic microcontaminants, the 4-octylphenol was found in the majority of the samples (91%), followed by caffeine (81%), naproxen (79%), cimetidine (77%) and atenolol (76%). The less frequent organic microcontaminants were metformine (1,5%), miconazole (1,5 %) acyclovir (2,2%) and bezafibrate (2,2 %). The results of those analyses were treated by principal component analysis and it was possible to relate the observed contamination profile with water quality index data from the sampling points.-
Idioma: dc.languagept_BR-
Direitos: dc.rightsAutorização concedida ao Repositório Institucional da UFOP pelo autor, 02/03/2015, com as seguintes condições: disponível sob Licença Creative Commons 3.0, que permite copiar, distribuir e transmitir o trabalho, desde que seja citado o autor e licenciante. Não permite o uso para fins comerciais nem a adaptação desta.-
Palavras-chave: dc.subjectCromatografia líquida-
Palavras-chave: dc.subjectEspectrometria de massa-
Palavras-chave: dc.subjectFluorescência de raio x-
Título: dc.titleMonitoramento de microcontaminantes orgânicos por métodos cromatográficos acoplados a espectrometria de massa e inorgânicos por fluorescência de pós-graduação em engenharia ambiental raios–x por reflexão total nas águas da Bacia do Rio Doce.-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - UFOP

Não existem arquivos associados a este item.