Descrição: dc.descriptionO presente trabalho teve como objetivo avaliar o comportamento de um aço do tipo AISI 304 em diferentes meios cloretados, bem como a influência de um concentrador geométrico de tensão (entalhe), quanto ao fenômeno CST. As técnicas de avaliação empregadas foram: deformação constante do eletrodo e carga constante no eletrodo. Os meios corrosivos adotados foram HCl 1M (pH @ 0,00) a temperatura ambiente e MgCl2 42% (massa) a 143°C (temperatura de ebulição). Utilizando ensaios de polarização potenciodinâmica caracterizouse eletroquimicamente os meios cloretados NaCl 3,5% (massa) e HCl 1M (pH @ 0,00). Observou-se que os Corpos de Prova (CPs) ensaiados em solução de MgCl2 42% (massa) em ebulição e HCl 1M (pH @ 0,00) sofreram CST para níveis de carga abaixo do limite de escoamento do material ( e). A suscetibilidade foi maior nos ensaios realizados em MgCl2 em ebulição. Observou-se também que quanto maior o nível de carregamento menor o tempo necessário para o desenvolvimento da CST. A presença do entalhe reduziu o tempo necessário para a fratura dos CPs. __________________________________________________________________________________________-
Descrição: dc.descriptionABSTRACT: This study aimed to evaluate the behavior of a steel type AISI 304 in different chlorinated media as well as the influence of a geometric stress concentrator (notch) on the SCC phenomenon. The employed evaluation techniques were: constant strain of the electrode and constant load on the electrode. The corrosive medias used were 1M HCl (pH @ 0.00) at room temperature and MgCl2 42% (mass) to 143 °C (boiling heat). Using potentiodynamic polarization tests, the chlorinated environments NaCl 3.5% (mass) and 1M HCl (pH @ 0.00) were characterized electrochemically. It was observed that the specimens tested in 42% MgCl2 solution (mass) in boiling point 1 M HCl (pH @ 0.00) suffered SCC for load levels below the yield stress of material ( ys). The susceptibility was higher in studies performed in boiling MgCl2. It was also observed that the higher loading level, the less time required for the development of CST. The presence of the notch reduced the time required for fracture of the specimens.-
Idioma: dc.languagept_BR-
Publicador: dc.publisherPrograma de Pós-Graduação em Engenharia de Materiais. Rede Temática em Engenharia de Materiais, Pró-Reitoria de Pesquisa e Pós-Graduação, Universidade Federal de Ouro Preto.-
Palavras-chave: dc.subjectCorrosão sob tensão-
Palavras-chave: dc.subjectEntalhe-
Palavras-chave: dc.subjectAço inoxidável-
Palavras-chave: dc.subjectCloretos-
Palavras-chave: dc.subjectEngenharia de superfície-
Título: dc.titleEfeito de entalhe e de meios cloretados na corrosão sob tensão de um aço inoxidável ABNT 304-