Descrição: dc.description | Associadas à industrialização do processo construtivo no Brasil, têm sido desenvolvidas estruturas metálicas mais leves e econômicas, utilizando perfis formados a frio de aço galvanizado. Uma das soluções construtivas que empregam esses perfis é o sistema Light Steel Framing, que reproduz os princípios da industrialização da construção civil, como a racionalização, padronização, coordenação modular e transformação do canteiro de obras em linha de montagem. Porém, como a tecnologia do Light Steel Framing é recente no Brasil, há ainda algumas adaptações climáticas dos projetos a serem feitas, por ser o sistema de concepção importado e com uma linguagem típica de seu país de origem. Tendo em vista esses aspectos, neste trabalho faz-se a avaliação do desempenho térmico de duas edificações unifamiliares em Light Steel Framing, ventiladas naturalmente, via simulação numérica utilizando o software EnergyPlus. Realiza-se um estudo das temperaturas internas dos ambientes, considerando a resposta global da edificação e verificando o cumprimento das exigências de conforto térmico de seus usuários. Neste estudo são contempladas como regiões climáticas as cidades de Curitiba, Belo Horizonte, Brasília, Goiânia, Teresina e Belém, escolhidas de forma a contemplar o maior número possível de zonas bioclimáticas definidas na norma NBR 15220:2005 de desempenho térmico de edificações. Os fechamentos utilizados na análise foram classificados em função do atraso térmico recomendado pela norma NBR 15220:2005. Os resultados obtidos permitem constatar que para todos os casos, o uso dos fechamentos e cobertura com atraso térmico indicados pela norma foram capazes de amortecer os picos de calor num dia típico de verão. Como os modelos propostos contemplam edificações com zonas (cômodos) pequenas, a carga térmica interna (perfil de ocupação/iluminação/equipamentos) tem grande influência na resposta do ambiente às interações térmicas com o clima externo. _______________________________________________________________________________________________________________________________________ | - |
Descrição: dc.description | ABSTRACT: Associated with the Brazilian construction industry, lighter and more economic metallic structures have been developed using galvanized cold-formed steel shapes. One of the solutions for construction that can be applied to these shapes is the Light Steel Framing System, which uses such construction industry principles as: logic, standardization, modular coordination, and assembly at the work site. However, the Light Steel Framing process is recent in Brazil, and is still undergoing some climatic adaptations for this country, since its concepts were first introduced in a foreign country and in that country's language. With these aspects in mind, in this work it is evaluated the thermal performance of two single-family constructions, employing Light Steel Framing in a naturally cooled atmosphere, was performed by simulation using the EnergyPlus thermal behavior software. Internal temperatures were studied, taking into consideration the overall response of the building and its compliance to personal comfort requirements for the inhabitants. In this study, the cities of Curitiba, Belo Horizonte, Brasilia, Goiânia, Teresina and Belém are contemplated as climatic regions, chosen to embrace the biggest possible number of defined bio-climatic zones in norm NBR 15220:2005 of thermal performance in constructions. The closings used in the analysis had been classified in function of the thermal delay recommended by norm NBR 15220:2005. The obtained results demonstrated that for all the cases, the use of outside walls and roofs with thermal insulation, according the Brazilian Standard NBR 15220:2005 for thermal performance in buildings, were able to cushion the peak heat temperatures of a typical summer. As the considered models contemplate constructions with small zones, the internal thermal load (occupation profile/illumination/equipment) has great influence in the reply of the environment to the thermal interactions with the external climate. | - |
Idioma: dc.language | pt_BR | - |
Publicador: dc.publisher | Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. | - |
Palavras-chave: dc.subject | Estruturas metálicas | - |
Palavras-chave: dc.subject | Ventilação | - |
Palavras-chave: dc.subject | Engenharia térmica | - |
Título: dc.title | Avaliação do desempenho térmico de edificações unifamiliares em light steel framing | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - UFOP |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: