Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.creator | Lobo, Fabiana Aparecida | - |
Autor(es): dc.creator | Goveia, Danielle | - |
Autor(es): dc.creator | Oliveira, Adriana Paiva de | - |
Autor(es): dc.creator | Romão, Luciane Pimenta Cruz | - |
Autor(es): dc.creator | Fraceto, Leonardo Fernandes | - |
Autor(es): dc.creator | Dias Filho, Newton Luiz | - |
Autor(es): dc.creator | Rosa, André Henrique | - |
Data de aceite: dc.date.accessioned | 2019-11-06T13:25:44Z | - |
Data de disponibilização: dc.date.available | 2019-11-06T13:25:44Z | - |
Data de envio: dc.date.issued | 2012-11-29 | - |
Data de envio: dc.date.issued | 2012-11-29 | - |
Data de envio: dc.date.issued | 2011 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/123456789/1893 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/555168 | - |
Descrição: dc.description | This paper proposes a low cost, simple, fast method for determining Ni and Cd in biodiesel samples by graphitefurnaceatomicabsorptionspectrometry (GFAAS). The method was evaluated in biodiesel from different sources. Tungsten was used as a permanent modifier and the samples were prepared in the form of microemulsions, by mixing about 0.5 g of biodiesel with 5 g of surfactant (Triton X-100) in volumetric flasks and completing the volume with HNO3 1% (v/v). The detection limits obtained for Ni and Cd in microemulsions were ≤0.9 and 0.1 μg L−1, respectively. The relative standard deviation (% R.S.D., n = 12) was ≤8.20% for Ni (washed animal fat sample) and ≤4.71% for Cd (sunflower oil sample). Accuracy was checked based on addition and recovery experiments, which yielded recovery rates varying from 93% to 108% for Ni and from 98% to 116% for Cd. Sample preparation is rapid and easy, and the use of an inorganic standard for calibration makes this sample preparation procedure suitable for routine applications. | - |
Idioma: dc.language | en | - |
Direitos: dc.rights | O Periódico Fuel concede permissão para depósito deste artigo no Repositório Institucional da UFOP. Número da licença: 3313100414118 | - |
Palavras-chave: dc.subject | Biodiesel | - |
Palavras-chave: dc.subject | Absorptionspectrometry | - |
Palavras-chave: dc.subject | Microemulsions | - |
Palavras-chave: dc.subject | Metals | - |
Título: dc.title | Development of a method to determine Ni and Cd in biodiesel by graphite furnace atomic absorption spectrometry | - |
Aparece nas coleções: | Repositório Institucional - UFOP |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: