???dc.contributor.advisor???: dc.contributor.advisor | Benedito, Raphael Augusto de Souza | - |
Autor(es): dc.contributor.author | Justi, Alyne Nogueira | - |
Autor(es): dc.contributor.author | Mazza, Felipe Daniel | - |
Autor(es): dc.contributor.author | Fogaça, Luciana Rinaldi | - |
Data de aceite: dc.date.accessioned | 2015-03-19T17:56:49Z | - |
Data de aceite: dc.date.accessioned | 2017-03-17T14:41:40Z | - |
Data de disponibilização: dc.date.available | 2015-03-19T17:56:49Z | - |
Data de disponibilização: dc.date.available | 2017-03-17T14:41:40Z | - |
Fonte completa do material: dc.identifier | http://repositorio.roca.utfpr.edu.br/jspui/handle/1/3221 | - |
???dc.identifier.citation???: dc.identifier.citation | JUSTI, Alyne Nogueira; MAZZA, Felipe Daniel; FOGAÇA, Luciana Rinaldi. Análise estática do ponto de colapso de tensão através do método do fluxo de potência continuado. 2014. 74 f. Trabalho de Conclusão de Curso (Graduação) – Universidade Tecnológica Federal do Paraná, Curitiba, 2014. | pt_BR |
Fonte: dc.identifier.uri | http://www.educapes.capes.gov.br/handlecapes/171453 | - |
Resumo: dc.description.abstract | The growing energetic demand and the high complexity of eletric power systems nowadays, added to the consumers high level of requirements, demands s higher quality power supply service. As parameters of quality, lies its continuity (service quality) and adequate voltage profile (product quality), even after disturbances. This way, it becomes essential to the operator to know the system'sactual state and, furthermore, to dispose of tools to foresee situations that would compromise the system’s regular work. Among these situations, figures the phenomenon of voltage instability (or voltage coalapse). The aim of the present paper is to study the main concepts of power systems stability, focusing on voltage stability. Within this theme, continuous power flow taking the load as a parameter for continuity. Systems of a maximum of 5 bars are analyzed with the aid of a computational tool that applies the continuous power flow and plots the so called PV and PQ curves. With these curves, it is possible to estimate the collapse point of the system, which represents the maximum load that the it is able to take without suffering from voltage instability. Corrective measures are also simulated, such as capacitors bank introduction and the addition of extra transmission lines on the system, aiming to verify what is the contribution of this procedures on the control of the load margin. | pt_BR |
Palavras-chave: dc.subject | Sistemas de energia elétrica | pt_BR |
Palavras-chave: dc.subject | Sistemas de energia elétrica - Estabilidade | pt_BR |
Palavras-chave: dc.subject | Fator de potência | pt_BR |
Palavras-chave: dc.subject | Electric power systems | pt_BR |
Palavras-chave: dc.subject | Electric power system stability | pt_BR |
Palavras-chave: dc.subject | Electric power factor | pt_BR |
Título: dc.title | Análise estática do ponto de colapso de tensão através do método do fluxo de potência continuado | pt_BR |
Tipo de arquivo: dc.type | outro | pt_BR |
Aparece nas coleções: | Repositorio Institucional da UTFPR - RIUT |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: