Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
???dc.contributor.advisor???: dc.contributor.advisor | Raia, Maria de Fátima Ribeiro | - |
Autor(es): dc.contributor.author | Nogueira, Diego Rodrigo de Freitas | - |
Autor(es): dc.contributor.author | Buzzatto, João Ricardo Ferreira | - |
Autor(es): dc.contributor.author | Suzuki, Rafael Kenji Ribeiro | - |
Data de aceite: dc.date.accessioned | 2015-03-19T17:13:50Z | - |
Data de aceite: dc.date.accessioned | 2017-03-17T14:41:28Z | - |
Data de disponibilização: dc.date.available | 2015-03-19T17:13:50Z | - |
Data de disponibilização: dc.date.available | 2017-03-17T14:41:28Z | - |
Fonte completa do material: dc.identifier | http://repositorio.roca.utfpr.edu.br/jspui/handle/1/3217 | - |
???dc.identifier.citation???: dc.identifier.citation | NOGUEIRA, Diego Rodrigo de Freitas; BUZZATTO, João Ricardo Ferreira; SUZUKI, Rafael Kenji Ribeiro. Estudo de viabilidade técnica e econômica da instalação de uma bomba de calor no processo de pintura da Electrolux do Brasil, planta Guabirotuba, Curitiba - PR. 2014. 88 f. Trabalho de Conclusão de Curso (Graduação) – Universidade Tecnológica Federal do Paraná, Curitiba, 2014. | pt_BR |
Fonte: dc.identifier.uri | http://www.educapes.capes.gov.br/handlecapes/171379 | - |
Resumo: dc.description.abstract | Electrolux has a program called Green Spirit, which the main target is the reduction of energy consumption, as also the reduction of gas emission and detergents that attack the environment. Align with the program, this study analyze the feasibility of installation of a heat pump in the degreaser process at the paint shop of factory 1 at Electrolux of Guabirotuba. The study is to replace the water heating that uses a natural gas boiler, for a system that reuses heat. The new system proposes the heat removal from the chiller system responsible for the acclimatization of the painting booth, reducing amount of work needed to cool the water that exchange heat with the ambient. So the thermal energy is reused on the water heating of the boiler system that heats the degreaser process water. With this study, the installation of a heat pump eliminates the natural gas consumption, estimating the reduction of methane emission, CH4. On the other side, the pump operation also able the reduction of the chiller electricity consumption. The study of using the heat pump at Electrolux, besides to help achieve the Green Spirit program targets, shows a great money savings, with a nearly one year payback. | pt_BR |
Palavras-chave: dc.subject | Desenvolvimento sustentável | pt_BR |
Palavras-chave: dc.subject | Refrigeração | pt_BR |
Palavras-chave: dc.subject | Indústrias - Conservação de energia | pt_BR |
Palavras-chave: dc.subject | Sustainable development | pt_BR |
Palavras-chave: dc.subject | Refrigeration and refrigerating machinery | pt_BR |
Palavras-chave: dc.subject | Industries - Energy conservation | pt_BR |
Título: dc.title | Estudo de viabilidade técnica e econômica da instalação de uma bomba de calor no processo de pintura da Electrolux do Brasil, planta Guabirotuba, Curitiba - PR | pt_BR |
Tipo de arquivo: dc.type | outro | pt_BR |
Aparece nas coleções: | Repositorio Institucional da UTFPR - RIUT |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: