Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
???dc.contributor.advisor???: dc.contributor.advisor | Mazer, Wellington | - |
Autor(es): dc.contributor.author | Santos, Jaqueline Cardoso Pereira dos | - |
Autor(es): dc.contributor.author | Prueter, Luiz Guilherme | - |
Autor(es): dc.contributor.author | Sadula, Tatyana | - |
Data de aceite: dc.date.accessioned | 2014-06-05T14:10:09Z | - |
Data de aceite: dc.date.accessioned | 2017-03-17T14:39:37Z | - |
Data de disponibilização: dc.date.available | 2014-06-05T14:10:09Z | - |
Data de disponibilização: dc.date.available | 2017-03-17T14:39:37Z | - |
Data de envio: dc.date.issued | 2014-06-05 | - |
Fonte completa do material: dc.identifier | http://repositorio.roca.utfpr.edu.br/jspui/handle/1/2071 | - |
???dc.identifier.citation???: dc.identifier.citation | SANTOS, Jaqueline Cardoso Pereira dos; PRUETER, Luiz Guilherme; SADULA, Tatyana. Estudo comparativo da resistência à compressão de prismas de argamassa química e argamassa convencional industrializada. 2013. 55 f. Trabalho de Conclusão de Curso (Graduação) – Universidade Tecnológica Federal do Paraná, Curitiba, 2013. | pt_BR |
Fonte: dc.identifier.uri | http://www.educapes.capes.gov.br/handlecapes/170699 | - |
Resumo: dc.description.abstract | The masonry has been widely used in various regions of Brazil, showing itself as a growing market for this type of construction technique. This research studies the compressive strength of concrete block prisms seated with chemical mortar type A and B and conventional mortar industrialized, aiming to analyze comparatively the results. The use of chemical mortar derives from the construction site stockpiles of sand, cement and lime, with no need to add any component, because the product already has a satisfactory workability, in addition to be already prepared for a determined resistance so the constructor just need to make an analysis about the costs. The concrete blocks used in the tests did not pass by the drying step, since the intention was to perform tests on blocks in real conditions of work, a factor which had great influence on adherence and conferred it a low initial resistance to chemical mortars. This research also made studies about paver mortar type A and type B, however the results were disconsidered, for they were executed with different thicknesses and different contact areas, making the analysis difficult because the values were quite different. Finally an analysis was made at the time of the prism breaking to analyze where the rupture began. | pt_BR |
Palavras-chave: dc.subject | Argamassa | pt_BR |
Palavras-chave: dc.subject | Alvenaria | pt_BR |
Palavras-chave: dc.subject | Blocos de concreto | pt_BR |
Palavras-chave: dc.subject | Mortar | pt_BR |
Palavras-chave: dc.subject | Masonry | pt_BR |
Palavras-chave: dc.subject | Concrete blochs | pt_BR |
Título: dc.title | Estudo comparativo da resistência à compressão de prismas de argamassa química e argamassa convencional industrializada | pt_BR |
Tipo de arquivo: dc.type | outro | pt_BR |
Aparece nas coleções: | Repositorio Institucional da UTFPR - RIUT |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: