Reuso de água da chuva coletada no bloco C da Universidade Tecnológica Federal do Paraná câmpus Campo Mourão

Registro completo de metadados
MetadadosDescriçãoIdioma
???dc.contributor.advisor???: dc.contributor.advisorMazzer, Helton Rogério-
Autor(es): dc.contributor.authorKruger, Paulo Ricardo-
Data de aceite: dc.date.accessioned2014-03-17T20:27:32Z-
Data de aceite: dc.date.accessioned2017-03-17T14:38:39Z-
Data de disponibilização: dc.date.available2014-03-17T20:27:32Z-
Data de disponibilização: dc.date.available2017-03-17T14:38:39Z-
Data de envio: dc.date.issued2014-03-17-
Fonte completa do material: dc.identifierhttp://repositorio.roca.utfpr.edu.br/jspui/handle/1/1885-
???dc.identifier.citation???: dc.identifier.citationKRUGER, Paulo Ricardo. Reuso de água da chuva coletada no bloco C da Universidade Tecnológica Federal do Paraná câmpus Campo Mourão. 2012. 67 f. Trabalho de Conclusão de Curso (Graduação) – Universidade Tecnológica Federal do Paraná, Campo Mourão, 2012.pt_BR
Fonte: dc.identifier.urihttp://www.educapes.capes.gov.br/handlecapes/170312-
Resumo: dc.description.abstractThis study aims to evaluate the implantation of a water reuse system on the C block from Universidade Tecnológica Federal do Paraná campus Campo Mourão. Considering that public agencies are places that usually receive a large amount of people and require maintenances such as cleaning and hygiene constantly, which increases water consumption. The Universidade Tecnologica Federal do Paraná fits this pattern, which makes it an important object of this study. It’s important to use the pluvial water reuse system on UTFPR to obtain a rationalization of potable water and thus preserve the water resources on the region. This study collected data on household cleaning and hydro sanitary appliances in two stages, during vacations and during school year. These data allows us to obtain the estimated consumption along with precipitation data from the past 11 years on the region, the 20m³ tank was calculated using the Rippl diagram. Performing a budget could confirm the possibility of deploying this system at Universidade Tecnológica Federal do Paraná campus Campo Mourão and it would have a payback period of investment in approximately 6 years and 6 months if the university would be charged for the water used, it would provide a saving of 520m³ per year of potable water.pt_BR
Palavras-chave: dc.subjectÁguas pluviaispt_BR
Palavras-chave: dc.subjectÁgua - Captaçãopt_BR
Palavras-chave: dc.subjectÁgua - Reusopt_BR
Palavras-chave: dc.subjectRain-water (Water-supply)pt_BR
Palavras-chave: dc.subjectWater, harvestingpt_BR
Palavras-chave: dc.subjectWater reusept_BR
Título: dc.titleReuso de água da chuva coletada no bloco C da Universidade Tecnológica Federal do Paraná câmpus Campo Mourãopt_BR
Tipo de arquivo: dc.typeoutropt_BR
Aparece nas coleções:Repositorio Institucional da UTFPR - RIUT

Não existem arquivos associados a este item.