Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
???dc.contributor.advisor???: dc.contributor.advisor | Liz, Marcus Vinicius de | - |
???dc.contributor.advisor???: dc.contributor.advisor | Zamora, Patricio Guillermo Peralta | - |
Autor(es): dc.contributor.author | Teixeira, Francisco Kozel | - |
Data de aceite: dc.date.accessioned | 2013-07-11T16:48:58Z | - |
Data de aceite: dc.date.accessioned | 2017-03-17T14:25:41Z | - |
Data de disponibilização: dc.date.available | 2017-03-17T14:25:41Z | - |
Data de envio: dc.date.issued | 2013-07-11 | - |
Fonte completa do material: dc.identifier | http://repositorio.roca.utfpr.edu.br/jspui/handle/1/1019 | - |
???dc.identifier.citation???: dc.identifier.citation | TEIXEIRA, Francisco Kozel. Determinação do estrógeno 17 β-estradiol (E2), em uma estação de tratamento de efluentes. 2013. 61 f. Trabalho de Conclusão de Curso (Graduação) – Universidade Tecnológica Federal do Paraná, Curitiba, 2013. | pt_BR |
Fonte: dc.identifier.uri | http://www.educapes.capes.gov.br/handlecapes/168481 | - |
Resumo: dc.description.abstract | In this paper it was applied an analytical method in order to perform the verification of the efficiency of removal of the sex hormone 17β-estradiol (E2) in a wastewater treatment plant, evaluating the degradation of this compound by conventional treatment used at this station, located in the municipality of Curitiba-PR. First it was constructed a calibration curve - concentrations between 5 e 1000 µgL-1 - using E2 standards to assess the linearity of the response in this range. Then tests were performed on solid phase extraction (SPE) cartridges in ultra-pure water in order to check the recovery of these hormones for further pre-concentration. Sewage samples were taken both upstream and downstream of a sewage treatment plant, which were then filtered through glass-fiber membrane and divided into aliquots of 300 mL, which were divided into aliquots without and with addition of standard (50, 100 and 300 ngL-1), pre-concentrated using SPE, reconstituted, and finally analyzed by high performance liquid chromatography coupled with a fluorescence detector (HPLC-FD). Recoveries in water were higher than 95%, while the recoveries in sewage were between 40 and 70%. As a result of analyzes it was concluded that characteristic chromatographic peaks of E2 were not found and E2 concentration was below the limit of detection and quantitation established in this paper. | pt_BR |
Palavras-chave: dc.subject | Águas residuais - Análise | pt_BR |
Palavras-chave: dc.subject | Água - Estações de tratamento | pt_BR |
Palavras-chave: dc.subject | Cromatografia a líquido de alta eficiência | pt_BR |
Palavras-chave: dc.subject | Sewage - Analysis | pt_BR |
Palavras-chave: dc.subject | Water treatment plants | pt_BR |
Palavras-chave: dc.subject | High performance liquid chromatography | pt_BR |
Título: dc.title | Determinação do estrógeno 17 β-estradiol (E2), em uma estação de tratamento de efluentes | pt_BR |
Tipo de arquivo: dc.type | outro | pt_BR |
Aparece nas coleções: | Repositorio Institucional da UTFPR - RIUT |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: