Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
???dc.contributor.advisor???: dc.contributor.advisor | Alves, Gilberto Manoel | - |
Autor(es): dc.contributor.author | Reis, Josilene Ferrari | - |
Autor(es): dc.contributor.author | Souza, Wellington Linconl Chimanski de | - |
Autor(es): dc.contributor.author | Jorge Filho, Sérgio Luiz de Oliveira | - |
Data de aceite: dc.date.accessioned | 2012-05-25T16:38:41Z | - |
Data de aceite: dc.date.accessioned | 2017-03-17T13:40:27Z | - |
Data de disponibilização: dc.date.available | 2012-05-25T16:38:41Z | - |
Data de disponibilização: dc.date.available | 2017-03-17T13:40:27Z | - |
Data de envio: dc.date.issued | 2012-05-25 | - |
Fonte completa do material: dc.identifier | http://repositorio.roca.utfpr.edu.br/jspui/handle/1/323 | - |
???dc.identifier.citation???: dc.identifier.citation | REIS, Josilene Ferrari; SOUZA, Wellington Linconl Chimanski de; JORGE FILHO, Sérgio Luiz de Oliveira. Medição da vazão da usina hidrelétrica de Roncador. 2011. 92 f. Trabalho de Conclusão de Curso (Graduação) – Universidade Tecnológica Federal do Paraná, Curitiba, 2011. | pt_BR |
Fonte: dc.identifier.uri | http://www.educapes.capes.gov.br/handlecapes/167021 | - |
Resumo: dc.description.abstract | This work presents the results of flow measurement in MHP Roncador, located in Bocaiúva do Sul, Brazil. MHP Roncador was disabled forty years ago and having no information about its hydrologic history. Was done a research about flow measurement methods used in micro hydroelectric plants. Was done five measurements campaigns in MHP Roncador’s reservoir and in each campaign were used two methods: Weir and Float. The first method could be used because there was an existing weir in the place. The second method was used because it`s a low cost method. The error between the two methods’ results was less than 5%, validating the measurements. Was obtained the historical series of flows from 1985 to 2005 using a transposition factor and the historical series of HP Gov. Pedro Viriato Parigot de Souza, located in the same watershed that MHP Roncador. Using the historical series was obtained the permanence curve and the hydrograph for a period of 21 years. | pt_BR |
Palavras-chave: dc.subject | Medidores de fluxo | pt_BR |
Palavras-chave: dc.subject | Usinas hidrelétricas | pt_BR |
Palavras-chave: dc.subject | Hidrologia | pt_BR |
Palavras-chave: dc.subject | Flow meters | pt_BR |
Palavras-chave: dc.subject | Hydroelectric power plants | pt_BR |
Palavras-chave: dc.subject | Hydrology | pt_BR |
Título: dc.title | Medição da vazão da usina hidrelétrica de Roncador | pt_BR |
Tipo de arquivo: dc.type | outro | pt_BR |
Aparece nas coleções: | Repositorio Institucional da UTFPR - RIUT |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: