Lighting and noise levels in compost dairy barns with natural and forced ventilation

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorAndrade, R. R.-
Autor(es): dc.creatorTinôco, I. F. F.-
Autor(es): dc.creatorDamasceno, F. A.-
Autor(es): dc.creatorBarbari, M.-
Autor(es): dc.creatorValente, D. A.-
Autor(es): dc.creatorVilela, M. O.-
Autor(es): dc.creatorSouza, C. F.-
Autor(es): dc.creatorConti, L.-
Autor(es): dc.creatorRossi, G.-
Data de aceite: dc.date.accessioned2026-02-09T12:46:43Z-
Data de disponibilização: dc.date.available2026-02-09T12:46:43Z-
Data de envio: dc.date.issued2020-08-12-
Data de envio: dc.date.issued2020-08-12-
Data de envio: dc.date.issued2019-
Fonte completa do material: dc.identifierhttps://repositorio.ufla.br/handle/1/42369-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/1168099-
Descrição: dc.descriptionThe housing system, called compost barn, is attracting the interest of several farmers. It allows dairy cows to remain in free movement inside a shed without any containment partitions like those used in freestall barns. In Brazil the compost barns with open sides are very common, but recently some closed barns with climatic control systems have been implemented. The objective of this work was to evaluate and compare lighting and noise levels in an open compost barn with natural ventilation and in a closed compost barn with a climate control system. The latter one is based on tunnel ventilation: inlet of air trough evaporative cellulose panels and exit through fans placed on the opposite wall. Through analysis of the collected data it was observed that the sound pressure recorded inside both analysed buildings did not exceed the ranges of noise discomfort recommended for the rearing of animals. However, the sound pressure amplitude inside the barn with climate control system was greater than in the open barn. The light intensity was significantly lower in the closed barn when compared to the open barn (84.96 and 1,413.58 lx, respectively). The artificial lighting system distributed throughout the closed barn was not sufficient to maintain brightness within the recommended range for lactating cows. In addition, it was found that in the closed building with forced ventilation, the highest brightness values are located near the exhaust fans.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languageen-
Publicador: dc.publisherFaculty of Agronomy, Estonian Agricultural University-
Direitos: dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International-
Direitos: dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International-
Direitos: dc.rightsacesso aberto-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/-
???dc.source???: dc.sourceAgronomy Research-
Palavras-chave: dc.subjectAnimal facility-
Palavras-chave: dc.subjectDairy cows-
Palavras-chave: dc.subjectAnimal welfare-
Palavras-chave: dc.subjectCompost-bedded pack barn-
Palavras-chave: dc.subjectLight intensity-
Palavras-chave: dc.subjectInstalações animais-
Palavras-chave: dc.subjectBovinos leiteiros-
Palavras-chave: dc.subjectBem estar animal-
Palavras-chave: dc.subjectIntensidade da luz-
Título: dc.titleLighting and noise levels in compost dairy barns with natural and forced ventilation-
Tipo de arquivo: dc.typeArtigo-
Aparece nas coleções:Repositório Institucional da Universidade Federal de Lavras (RIUFLA)