Consistency analysis of COVID-19 nucleic acid tests and the changes of lung CT

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorZhifeng, Jiang-
Autor(es): dc.creatorFeng, Aiqiao-
Autor(es): dc.creatorLi, Tao-
Data de aceite: dc.date.accessioned2026-02-09T12:36:32Z-
Data de disponibilização: dc.date.available2026-02-09T12:36:32Z-
Data de envio: dc.date.issued2020-06-30-
Data de envio: dc.date.issued2020-06-30-
Data de envio: dc.date.issued2020-06-
Fonte completa do material: dc.identifierhttps://repositorio.ufla.br/handle/1/41621-
Fonte completa do material: dc.identifierhttps://www.sciencedirect.com/science/article/pii/S1386653220301013-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/1164721-
Descrição: dc.descriptionBackground COVID-19, the latest outbreak of infectious disease, has caused huge medical challenges to China and the entire globe. No unified diagnostic standard has been formulated. The initial diagnosis remains based on the positive of nucleic acid tests. However, early nucleic acid tests were identified to be negative in some patients, whereas the patients exhibited characteristic CT changes of lung, and positive test results appeared after repeated nucleic acid tests, having caused the failure to diagnose these patients early. The study aimed to delve into the relationships between initial nucleic acid testing and early lung CT changes in patients with COVID-19. Method In accordance with the latest COVID-19 diagnostic criteria, 69 patients diagnosed with COVID-19 treated in the infected V ward of Xiaogan Central Hospital from 2020/1/25 to 2020/2/6 were retrospectively analyzed. The consistency between the first COVID-19 nucleic acid test positive and lung CT changes was studied. In addition, the sensitivity and specificity of CT and initial nucleic acid were studied. Result The Kappa coefficient of initial nucleic acid positive changes and lung CT changes was −1.52. With a positive nucleic acid test as the gold standard, the sensitivity of lung CT was 12.00 %, 95 % CI: 4.6–24.3; with the changes of CT as the gold standard, the sensitivity of nucleic acid positive was 30.16 %, 95 % CI: 19.2−43.0. Conclusion The consistency between the initial positive nucleic acid test and the CT changes in the lungs is poor; low sensitivity was achieved for initial nucleic acid detection and CT changes.-
Idioma: dc.languageen-
Publicador: dc.publisherElsevier-
Direitos: dc.rightsrestrictAccess-
???dc.source???: dc.sourceJournal of Clinical Virology-
Palavras-chave: dc.subjectCOVID-19-
Palavras-chave: dc.subjectLung CT-
Palavras-chave: dc.subjectNucleic acid-
Título: dc.titleConsistency analysis of COVID-19 nucleic acid tests and the changes of lung CT-
Tipo de arquivo: dc.typeArtigo-
Aparece nas coleções:Repositório Institucional da Universidade Federal de Lavras (RIUFLA)

Não existem arquivos associados a este item.