Concordância dos parâmetros de composição corporal avaliados por bioimpedância e absorciometria de dupla emissão de raio-x em adultos de meia idade e idosos.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorCosta, Amina Chain-
Autor(es): dc.contributorhttp://lattes.cnpq.br/3496311737984056-
Autor(es): dc.contributorWahrlich, Vivian-
Autor(es): dc.contributorhttp://lattes.cnpq.br/6198647788690311-
Autor(es): dc.contributorBagni, Ursula Viana-
Autor(es): dc.contributorhttp://lattes.cnpq.br/7547309380502520-
Autor(es): dc.contributorSantos, Thalyta dos Anjos-
Autor(es): dc.contributorhttp://lattes.cnpq.br/3767850596941725-
Autor(es): dc.contributorhttp://lattes.cnpq.br/5626241697195687-
Autor(es): dc.contributorhttp://lattes.cnpq.br/0481410956438375-
Autor(es): dc.creatorCosta, Julia Miller Alves da-
Autor(es): dc.creatorGulpilhares, Maria Julia Ribeiro Dos Santos-
Data de aceite: dc.date.accessioned2025-08-21T20:15:28Z-
Data de disponibilização: dc.date.available2025-08-21T20:15:28Z-
Data de envio: dc.date.issued2025-02-25-
Data de envio: dc.date.issued2025-02-25-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/36951-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/1057696-
Descrição: dc.descriptionIntrodução: Em adultos saudáveis, a composição corporal pode se apresentar de forma constante, porém, no envelhecimento ocorrem alterações bem descritas na literatura, como a diminuição da massa livre de gordura mole (MLG_mole) e do conteúdo mineral ósseo (CMO), que compõem a massa livre de gordura (MLG), e aumento da massa gorda (MG). Para estimar a composição corporal (CC) existem diferentes métodos duplamente indiretos, dentre eles a bioimpedância elétrica (BIA), que é bastante utilizada na prática clínica. No entanto, há poucas avaliações utilizando o equipamento Biodynamics P450, por isso, visto a necessidade de mais avaliações com esse equipamento. Objetivo: Avaliar a concordância de um equipamento de bioimpedância elétrica para avaliação da composição corporal em adultos de meia idade e idosos. Métodos: A população de estudo foi composta por adultos acima de 50 anos de ambos os sexos, o recrutamento dos voluntários foi feito através de cartazes que foram fixados nos campi da universidade e em lugares de grande fluxo de pessoas, divulgação pessoa a pessoa e interesse dos indivíduos. Também foram obtidas as medidas de massa corporal e estatura. Foi realizada a análise descritiva das variáveis e a concordância entre os métodos foi verificada pelos gráficos de Bland & Altman. Também foi analisada a correlação das variáveis obtidas por BIA e DXA. Resultados: A idade média foi de 65,9 anos e o IMC médio foi de 27,1kg/m2. A média da MG por DXA foi de 27,1kg e BIA 23,3kg. Já as médias do percentual de GC avaliadas por DXA e BIA foram, 39,5% e 33,5%, respectivamente. Foram observadas associações positivas e significativas entre os parâmetros da CC avaliados pela BIA e pela DXA (r>0,830; p<0,001). A análise gráfica de Bland-Altman mostrou que a BIA subestimou os valores de MG e superestimou os valores de MLG. Conclusão: Os resultados do presente estudo sugerem que existe uma correlação entre as medidas obtidas por ambos os métodos, mas que não houve uma boa concordância e confiabilidade dessas medidas, havendo uma subestimação da massa gorda e uma superestimação da massa livre de gordura pela BIA na população estudada.-
Descrição: dc.descriptionIntroduction: In healthy adults, a body composition may be constant, however, there are no aging changes well described in the literature, such as a decrease in free soft fat mass (FMFM_soft) and bone mineral content (BMC), that composes the fat-free mass (FMF), and increased fat mass (FM). There are different doubly indirect methods to estimate body composition (BC), including bioelectrical impedance (BIA), which is widely used in clinical practice. However, there are few estimates using the Biodynamics P450 equipment, therefore, considering the need for more estimates with this equipment. Objective: To evaluate the concordance of an electrical bioimpedance device for assessing body composition in middle-aged and elderly adults. Methods: The study population consisted of adults over 50 years of age of both sexes, the recruitment of volunteers was done through posters that were fixed on university campuses and in places with a large flow of people, person-to-person disclosure and interest of individuals. Body mass and height measurements were also lost. A descriptive analysis of the variables was carried out and the agreement between the methods was verified using the Bland & Altman graphs. The variable variable was also influenced by BIA and DXA. Results: The average age was 65.9 years and the average BMI was 27.1kg/m2. The mean FM by DXA was 27.1kg and BIA 23.3kg. The mean percentage of GC evaluations by DXA and BIA were 39.5% and 33.5%, respectively. Positive associations and initiatives were observed between the WC parameters evaluated by BIA and DXA (r>0.830; p<0.001). A Bland-Altman plot analysis showed that BIA underestimated FFM values and overestimated FFM values. Conclusion: The results of the present study suggest that there is a dynamic between the measures followed by both methods, but that there was not a good agreement and reliability of these measures, with an underestimation of the fat mass and an overestimation of the fat-free mass by the BIA in the population studied.-
Descrição: dc.description42 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectComposição corporal-
Palavras-chave: dc.subjectBioimpedância Elétrica-
Palavras-chave: dc.subjectAbsorciometria de dupla emissão de raio-x-
Palavras-chave: dc.subjectAdultos-
Palavras-chave: dc.subjectComposição corporal-
Palavras-chave: dc.subjectImpedância elétrica-
Palavras-chave: dc.subjectAbsorciometria de fóton-
Palavras-chave: dc.subjectAdulto-
Palavras-chave: dc.subjectIdoso-
Palavras-chave: dc.subjectBody composition-
Palavras-chave: dc.subjectElectrical Bioimpedance-
Palavras-chave: dc.subjectX-ray dual emission absorptiometry-
Palavras-chave: dc.subjectAdults-
Título: dc.titleConcordância dos parâmetros de composição corporal avaliados por bioimpedância e absorciometria de dupla emissão de raio-x em adultos de meia idade e idosos.-
Tipo de arquivo: dc.typeTrabalho de conclusão de curso-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.