Avaliação da estabilidade do diâmetro em implantes cone morse com variações de angulação após instalação do abutment

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorCasado, Priscila Ladeira-
Autor(es): dc.contributorhttp://lattes.cnpq.br/5162476793291873-
Autor(es): dc.contributorCarvalho, Waldimir Rocha de-
Autor(es): dc.contributorhttp://lattes.cnpq.br/9754535008112037-
Autor(es): dc.contributorNascimento, Aldir Nascimento-
Autor(es): dc.contributorhttp://lattes.cnpq.br/0424081639785731-
Autor(es): dc.contributorNunes, Carlos Henrique Ramirez-
Autor(es): dc.contributorhttp://lattes.cnpq.br/5542471581795672-
Autor(es): dc.contributorMontenegro, Alexandre Campos-
Autor(es): dc.contributorhttp://lattes.cnpq.br/2759364304982879-
Autor(es): dc.contributorhttp://lattes.cnpq.br/9657229587486624-
Autor(es): dc.creatorCordeiro, Bruno Queiroz da Silva-
Data de aceite: dc.date.accessioned2025-08-21T20:11:48Z-
Data de disponibilização: dc.date.available2025-08-21T20:11:48Z-
Data de envio: dc.date.issued2025-07-03-
Data de envio: dc.date.issued2025-07-03-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/39102-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/1056370-
Descrição: dc.descriptionComplicações mecânicas em implantes osseointegrados, como o afrouxamento do pilar, podem resultar em uma diminuição do torque aplicado e, consequentemente, comprometer a longevidade do tratamento. Este estudo investigou as deformações plásticas induzidas pelo torque de inserção do pilar em implantes com conexão Cone Morse de 11.50 e 160. Oitenta espécimes compostas por implantes endósseos tipo Cone Morse foram divididas em dois grupos: Grupo 11.50 n=40) e Grupo 160 (n=40), contendo cada grupo implantes nas dimensões em mm de 3.5 (n=10), 3.8 (n=10), 4.5 (n=10), 5.0 (n=10). Todos os implantes utilizados foram da linha Strong SW, S.I.N – Implant System – São Paulo, Brasil. Medições iniciais e finais do diâmetro externo dos implantes foram obtidas antes e após a instalação dos pilares, utilizando o torque de acordo com as orientações do fabricante. Todos os implantes foram instalados em cilíndros de resina de poliacetal, de densidade 1,42g/cm³, com torque de 40N/cm. Após a confecção dos corpos de prova, foram realizadas as medições INICIAIS do diâmetro externo dos implantes. Após essas medições, todos os implantes receberam a instalação do pilar, com torque de 20N/cm. Os corpos de prova foram submetidos a uma máquina de medição por coordenadas tridimensionais, de forma a mensurar os diâmetros dos implantes antes e após a instalação do abutment. Os resultados indicaram um aumento não significativo no diâmetro na área cervical do corpo do implante após a aplicação de torque no pilar, conforme recomendado pelo fabricante. O torque aplicado aos pilares protéticos não produziu deformações na área cervical do corpo do implante Cone Morse.-
Descrição: dc.descriptionMechanical complications in osseointegrated implants, such as abutment loosening, can result in a decrease in the applied torque and consequently compromise the longevity of the treatment. This study investigated the plastic deformations induced by the insertion torque of the abutment in implants with Cone Morse connections of 11.50 and 160. Eighty specimens composed of Cone Morse type endosseous implants were divided into two groups: Group 11.50 (n=40) and Group 160 (n=40), with each group containing implants in dimensions in mm of 3.5 (n=10), 3.8 (n=10), 4.5 (n=10), 5.0 (n=10). All the implants used were from the Strong SW line, S.I.N – Implant System – São Paulo, Brazil. Initial and final measurements of the external diameter of the implants were obtained before and after the installation of the abutments, using the torque as per the manufacturer's instructions. All implants were installed in acetal resin cylinders with a density of 1.42g/cm³, with a torque of 40N/cm. After the preparation of the test specimens, INITIAL measurements of the external diameter of the implants were conducted. Following these measurements, all implants had the abutment installed with a torque of 20N/cm. The test specimens were subjected to a coordinate measuring machine to measure the diameters of the implants before and after abutment installation. The results indicated a non-significant increase in the diameter in the cervical area of the implant body after the application of torque on the abutment, as recommended by the manufacturer. The torque applied to the prosthetic abutments did not produce deformations in the cervical area of the Cone Morse implant body.-
Descrição: dc.description43 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectImplantes dentários-
Palavras-chave: dc.subjectConexão morse-
Palavras-chave: dc.subjectTorque protético-
Palavras-chave: dc.subjectDeformação plástica-
Palavras-chave: dc.subjectOsseointegração-
Palavras-chave: dc.subjectImplante dentário-
Palavras-chave: dc.subjectImplantação dentária endóssea-
Palavras-chave: dc.subjectProjeto do implante dentário - pivô-
Palavras-chave: dc.subjectOsseointegração-
Palavras-chave: dc.subjectDente suporte-
Palavras-chave: dc.subjectDental implants-
Palavras-chave: dc.subjectMorse connection-
Palavras-chave: dc.subjectProsthetic torque-
Palavras-chave: dc.subjectPlastic deformation-
Palavras-chave: dc.subjectOsseointegration-
Título: dc.titleAvaliação da estabilidade do diâmetro em implantes cone morse com variações de angulação após instalação do abutment-
Título: dc.titleAssessment of diameter stability in morse taper dental implants with different angulations after abutment connection.-
Tipo de arquivo: dc.typeTese-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.