Uso de fotorreatores UV para a remoção de diclofenaco, bezafibrato e etinilestradiol de esgoto tratado em sistema UASB - FBP.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorFaria, Eros de-
Autor(es): dc.creatorLima, Diego Roberto de Sousa-
Autor(es): dc.creatorXavier, Leandro Pablo dos Santos-
Autor(es): dc.creatorAquino, Sergio Francisco de-
Autor(es): dc.creatorAfonso, Robson José de Cássia Franco-
Autor(es): dc.creatorChernicharo, Carlos Augusto de Lemos-
Autor(es): dc.creatorGomes, Rafaela de Paiva-
Data de aceite: dc.date.accessioned2025-08-21T16:00:11Z-
Data de disponibilização: dc.date.available2025-08-21T16:00:11Z-
Data de envio: dc.date.issued2016-07-29-
Data de envio: dc.date.issued2016-07-29-
Data de envio: dc.date.issued2015-
Fonte completa do material: dc.identifierhttp://www.repositorio.ufop.br/handle/123456789/6702-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1590/S1413-41522015020000101320-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/1029727-
Descrição: dc.descriptionEste trabalho avaliou a remoção de diclofenaco (DCF), bezafibrato (BZF) e etinilestradiol (EE2) de efluentes de sistema UASB-FBP (reator anaeróbio de manta de lodo seguido de filtro biológico percolador) em fotorreatores UV de lâmpadas imersas (FRI) e emersas (FRE). Os resultados mostram que baixa eficiência de remoção de tais compostos foi obtida em ambos fotorreatores quando se utilizou baixo tempo de contato (~10 min) e baixa concentração inicial de fármacos (0,5 μg.L-1 para EE2, e 21 μg.L-1 para DCF e BZF). O aumento da concentração inicial de DCF (para 20 mg.L-1) e do tempo de contato (para 20 min) resultaram em aumento da eficiência de remoção (de 31 para 83% no FRI e de 36 para 86% no FRE), indicando que compostos dissolvidos presentes no efluente biológico afetaram adversamente a remoção de fármacos nos fotorreatores devido a competição pela radiação UV incidente.-
Descrição: dc.descriptionThis paper evaluated the removal of diclophenac (DCF), bezafibrate (BZF) and ethynylestradiol (EE2) from effluent of an anaerobic reactor coupled to a trickling filter (UASB-TF) in two types of UV photoreactors (immerse UV lamps – FRI and emmersed UV lamps – FRE). The results showed low removal efficiencies in both photoreactors when low contact times (10 min) and low initial concentration of such compounds was used (0.5 μg.L-1 for EE2 and 21 μg.L-1 for DCF and BZF). An increase in the initial concentration of DCF (to 20 mg.L-1) and of the contact time (to 20 min) led to an increase in the removal efficiency (from 31 to 83% in FRI and from 36 to 86% in FRE), suggesting that dissolved compounds present in the biological effluent adversely affected the removal of the pharmaceutical tested due to competition for the incident UV radiation.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsaberto-
Direitos: dc.rightsTodo o conteúdo do periódico Engenharia Sanitária e Ambiental, exceto onde identificado, está sob uma licença Creative Commons que permite copiar, distribuir e transmitir o trabalho em qualquer suporte ou formato desde que sejam citados o autor e o licenciante. Fonte: Engenharia Sanitária e Ambiental <http://www.scielo.br/scielo.php?script=sci_serial&pid=1413-4152&lng=en&nrm=iso>. Acesso em: 20 ago. 2019.-
Palavras-chave: dc.subjectFotorreator-
Palavras-chave: dc.subjectFármacos-
Palavras-chave: dc.subjectPost treatment-
Palavras-chave: dc.subjectSewage treatment-
Palavras-chave: dc.subjectTratamento esgoto sanitário-
Título: dc.titleUso de fotorreatores UV para a remoção de diclofenaco, bezafibrato e etinilestradiol de esgoto tratado em sistema UASB - FBP.-
Título: dc.titleUse of UV photoreactors to remove diclofenac, bezafibrate and ethynylestradiol from sewage treated in UASB - TF system.-
Aparece nas coleções:Repositório Institucional - UFOP

Não existem arquivos associados a este item.