Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorCarvalho, Espedito Felipe Teixeira de-
Autor(es): dc.creatorSilva Neto, João Trajano da-
Autor(es): dc.creatorSoares Junior, Paulo Roberto Ribeiro-
Autor(es): dc.creatorMaciel, Priscila de Souza-
Autor(es): dc.creatorFransozo, Hélder Luís-
Autor(es): dc.creatorBezerra, Augusto Cesar da Silva-
Autor(es): dc.creatorGouveia, Antônio Maria Claret de-
Data de aceite: dc.date.accessioned2025-08-21T15:35:29Z-
Data de disponibilização: dc.date.available2025-08-21T15:35:29Z-
Data de envio: dc.date.issued2022-02-16-
Data de envio: dc.date.issued2022-02-16-
Data de envio: dc.date.issued2019-
Fonte completa do material: dc.identifierhttp://www.repositorio.ufop.br/jspui/handle/123456789/14516-
Fonte completa do material: dc.identifierhttps://doi.org/10.3390/ma12213512-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/1019167-
Descrição: dc.descriptionThis work reports the main conclusions of a study on the mechanical behavior of concrete under ISO 834 fire with different cooling methods. The aim of this research was to provide reliable data for the analysis of structures damaged by fire. The experimental program used cylindrical concrete test specimens subjected to ISO 834 heating in a furnace up to maximum gas temperatures of 400, 500, 600, 700, and 800 ◦C. The compressive strength was measured in three situations: (a) at the different temperature levels reached in the furnace; (b) after a natural cooling process; and (c) after aspersion with water at ambient temperature. The results indicate that the concrete residual compressive strength is fairly dependent on the maximum temperature reached in the furnace and revealed that concrete of a lower strength preserved relatively higher levels of strength. The cooling method significantly influenced the strength, albeit at a lower intensity. In all cases, the residual strength remained in the range of 38% to 67% of the strength at ambient temperature. The statistical analysis showed that the data obtained by the experimental program are significant and confirmed the influence of the conditions imposed on the residual strength.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languageen-
Direitos: dc.rightsaberto-
Direitos: dc.rightsThis article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Fonte: o PDF do artigo.-
Palavras-chave: dc.subjectConcrete fire degradation-
Palavras-chave: dc.subjectResidual mechanical behavior-
Título: dc.titleInfluence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study.-
Aparece nas coleções:Repositório Institucional - UFOP

Não existem arquivos associados a este item.