Análise comparativa entre a força axial resistente de cálculo à compressão obtida pela ABNT NBR 8800:2008 com a obtida pela AISC : 360-22 para pilares mistos totalmente revestidos através de implementação python.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorFernandes, Walliston dos Santos-
Autor(es): dc.contributorSouza, Flávio Texeira de-
Autor(es): dc.contributorFernandes, Walliston dos Santos-
Autor(es): dc.contributorSouza, Flávio Texeira de-
Autor(es): dc.contributorRusso, Mário Luís Cabello-
Autor(es): dc.contributorRocha, Paulo Anderson Santana-
Autor(es): dc.contributorFernandes, William Luiz-
Autor(es): dc.creatorSouza, Roberto da Silva-
Data de aceite: dc.date.accessioned2025-08-21T15:18:24Z-
Data de disponibilização: dc.date.available2025-08-21T15:18:24Z-
Data de envio: dc.date.issued2024-09-12-
Data de envio: dc.date.issued2024-09-12-
Data de envio: dc.date.issued2023-
Fonte completa do material: dc.identifierhttps://www.repositorio.ufop.br/handle/123456789/18619-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/1009831-
Descrição: dc.descriptionPrograma de Pós-Graduação em Engenharia das Construções. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto.-
Descrição: dc.descriptionOs pilares mistos foram, inicialmente, utilizados de forma despretensiosa para as situações de incêndio na década de 40, no entanto na década de 60 surgiram os primeiros estudos para o uso deste tipo de estrutura para edifícios altos. No contexto brasileiro dos 10 maiores edifícios, classificados como altos, 9 são em concreto armado e somente um em estrutura mista. Neste sentido, considerando que os EUA é um dos países com maior tradição no uso de estruturas mistas, o presente trabalho teve por objetivo efetuar a comparação entre os valores de força axial resistente de cálculo à compressão, de pilares misto totalmente revestidos, obtidas pelo uso das metodologias de cálculo da ABNT NBR 8800:2008 e da AISC: 360-22, para avaliar a diferença entres resultados obtidos pelas diferentes normas, e verificar possíveis melhorias. Foi utilizado para o estudo um exemplo de pilar misto totalmente revestido, obtido na literatura, e a este foi avaliado o seu atendimento à ABNT NBR 8800:2008 e posterior obtenção da força axial resistente de cálculo à compressão utilizando as metodologias da norma brasileira e da norma americana. Além disso, com o auxílio do programa desenvolvido em Python sob a mesma configuração de pilar misto foram testados diversos perfis metálicos comerciais. Os resultados obtidos pela ABNT NBR 8800:2008 apresentaram valores superiores aos obtidos pela AISC:360-22. Deste modo, a norma americana apresentou resultados mais conservadores de força axial resistente de cálculo à compressão que a norma brasileira.-
Descrição: dc.descriptionComposite columns were initially used casually for fire situations in the 1940s; however, in the 1960s, the first studies emerged regarding their application in high-rise buildings. In the Brazilian context, among the top 10 tallest buildings, 9 are reinforced concrete, with only one employing composite structure. Considering the USA's extensive tradition in using composite structures, this study aimed to compare the calculated values of compressive axial resistance for fully encased composite columns using the calculation methodologies of ABNT NBR 8800:2008 and AISC: 360-22. The goal was to assess the differences in results between these norms and identify potential improvements. For this study, a fully encased composite column example from literature was utilized, evaluating its compliance with ABNT NBR 8800:2008 and subsequently calculating the compressive axial resistance using both Brazilian and American norm methodologies. Additionally, aided by a Python program configured for composite columns, various commercial metal profiles were tested. Results from ABNT NBR 8800:2008 showed higher values compared to those obtained from AISC: 360-22, indicating that the American norm provides more conservative results for compressive axial resistance calculations than its Brazilian counterpart.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsaberto-
Direitos: dc.rightsAttribution-NoDerivs 3.0 United States-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nd/3.0/us/-
Direitos: dc.rightsAutorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 15/08/2024 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e o licenciante. Não permite a adaptação.-
Palavras-chave: dc.subjectColunas - pilar misto-
Palavras-chave: dc.subjectNormas técnicas - engenharia-
Palavras-chave: dc.subjectSpecification for Structural Steel Buildings-
Palavras-chave: dc.subjectAnálise estrutural-
Palavras-chave: dc.subjectPython - linguagem de programação de computador-
Título: dc.titleAnálise comparativa entre a força axial resistente de cálculo à compressão obtida pela ABNT NBR 8800:2008 com a obtida pela AISC : 360-22 para pilares mistos totalmente revestidos através de implementação python.-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - UFOP

Não existem arquivos associados a este item.