Desempenho geotécnico de cortinas atirantadas executadas em Cascavel-PR.

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorPorto, Thiago Bomjardim-
Autor(es): dc.contributorPorto, Thiago Bomjardim-
Autor(es): dc.contributorFerreira, Lucas Deleon-
Autor(es): dc.contributorRincent, Jean Jacques-
Autor(es): dc.creatorOliveira, Thays Car Feliciano de-
Data de aceite: dc.date.accessioned2025-08-21T15:07:41Z-
Data de disponibilização: dc.date.available2025-08-21T15:07:41Z-
Data de envio: dc.date.issued2023-09-22-
Data de envio: dc.date.issued2023-09-22-
Data de envio: dc.date.issued2022-
Fonte completa do material: dc.identifierhttp://www.repositorio.ufop.br/jspui/handle/123456789/17467-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/1003032-
Descrição: dc.descriptionPrograma de Pós-Graduação em Engenharia Geotécnica. Núcleo de Geotecnia, Escola de Minas, Universidade Federal de Ouro Preto.-
Descrição: dc.descriptionAs estruturas de contenção atirantadas são amplamente utilizadas no cenário nacional, o que inclui o uso de tirantes para fins provisórios, principalmente em escavações de subsolos em regiões urbanas. Verifica-se a deficiência de dados quanto à capacidade de carga dos tirantes, considerando a ampla variabilidade geológico-geotécnica nacional. Assim, este trabalho teve o objetivo de estudar a capacidade de carga de tirantes para o contexto geológico-geotécnico de Cascavel-PR. Para tanto foram utilizados dados de duas obras do município, principalmente quanto a caracterização preliminar por sondagens e a boletins do controle tecnológico dos tirantes. Ademais foram coletadas amostras indeformadas de cada obra, para caracterização complementar mais detalhada dos índices físicos e parâmetros de resistência dos solos. A análise da capacidade de carga última dos tirantes foi realizada por meio de extrapolação matemática, visto que os tirantes eram provisórios e não atingiram a ruptura no procedimento de protensão. Também verificou-se a estabilidade global das cortinas atirantadas, em conjunto com análises de sensibilidade dos parâmetros geotécnicos, para uma avaliação preliminar das estruturas de contenção dos estudos de caso. Os resultados de caracterização indicaram que os maciços estudados eram constituídos por solos argilosos e argilo-siltosos. Encontrou-se uma ampla faixa de capacidade de carga dos tirantes, para a obra 1 de 45 a 97 kN/m e, para a obra 2 de 60 a 103 kN/m. Apesar da variabilidade, os resultados se enquadram em valores previamente apresentados na literatura para solos com caracterização geotécnica semelhante. As cortinas de ambos os estudos de caso apresentaram resultados satisfatórios de fator de segurança (FS) nas análises de estabilidade e a avaliação de sensibilidade indicou que os parâmetros de resistência do maciço são determinantes para o FS. Em suma, os resultados da pesquisa foram satisfatórios para auxiliar em definições básicas e importantes para análises de contenções atirantadas na região de estudo, principalmente quanto a faixas de resistência coerentes para o solo da região e valores de capacidade de carga para os tirantes.-
Descrição: dc.descriptionAnchored retaining structures are widely used in the national scenario, which includes use of grouted anchors (tieback anchors) for temporary purposes, mainly for underground excavations in urban regions. Data is lacking regarding pullout capacity of the anchors, when the wide national geological-geotechnical variability is considered. Thus, this work aimed to study the anchors pullout capacity for the geological-geotechnical context of Cascavel-PR, Brazil. For this purpose, data from two constructions (with excavation services) of the city were used, especially regarding the soil preliminary characterization (SPT tests) and anchors technological control (pretension bulletins). In addition, undisturbed samples were collected from each construction site, for complementary and more detailed characterization of the soil in terms of physical indices and resistance parameters. The analysis of the pullout capacity of the anchors was performed through mathematical extrapolation since the anchors were temporary and did not reach failure in the prestressing procedure. The global stability of the retaining structures was also verified, with sensitivity analysis of the geotechnical parameters, for a preliminary evaluation of the retaining structures. The characterization results indicated that the studied massifs were constituted by clay and clay-silt soils. A wide range of pullout anchor capacity was obtained, for site 1 from 45 to 97 kN/m and, for site 2 from 60 to 103 kN/m. Despite the variability, the results are in accordance with values previously presented in the literature for soils with a similar geotechnical characterization. The structures of both case studies presented satisfactory results for the safety factor (SF) in the stability analysis and the sensitivity analysis indicated that the soil strength parameters are determinant for the SF. In short, the research results were satisfactory in order to assist with basic and important definitions for anchored retaining walls analysis in the study region, mainly regarding consistent ranges for the resistance of the region’s soil and values of pullout capacity for the anchors.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsaberto-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/us/-
Direitos: dc.rightsAutorização concedida ao Repositório Institucional da UFOP pelo(a) autor(a) em 04/09/2018 com as seguintes condições: disponível sob Licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho, desde que sejam citados o autor e o licenciante. Não permite o uso para fins comerciais nem a adaptação.-
Palavras-chave: dc.subjectFundações - engenharia-
Palavras-chave: dc.subjectTirantes de rocha-
Palavras-chave: dc.subjectMecânica do solo - ensaio triaxial-
Palavras-chave: dc.subjectEstacaria - engenharia civil-
Título: dc.titleDesempenho geotécnico de cortinas atirantadas executadas em Cascavel-PR.-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - UFOP

Não existem arquivos associados a este item.