Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Bonfim, Marlio J. Couto | - |
Autor(es): dc.contributor | Universidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia Elétrica | - |
Autor(es): dc.creator | Nardi, Maurício | - |
Data de aceite: dc.date.accessioned | 2019-08-21T23:24:46Z | - |
Data de disponibilização: dc.date.available | 2019-08-21T23:24:46Z | - |
Data de envio: dc.date.issued | 2018-07-23 | - |
Data de envio: dc.date.issued | 2018-07-23 | - |
Data de envio: dc.date.issued | 2017 | - |
Fonte completa do material: dc.identifier | https://hdl.handle.net/1884/49162 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/1884/49162 | - |
Descrição: dc.description | Orientador : Prof. Dr. Marlio J. do C. Bonfim | - |
Descrição: dc.description | Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Engenharia Elétrica. Defesa: Curitiba, 25/08/2017 | - |
Descrição: dc.description | Inclui referências : f. 61-64 | - |
Descrição: dc.description | Resumo: A icterícia e uma manifestação clinica caracterizada pela coloração amarela da pele, mucosas e escleróticas devido a elevada concentração de bilirrubina na corrente sanguínea. Em casos de demora no diagnostico, o paciente pode desenvolver uma intoxicação na massa encefálica, provando uma encefalopatia que pode resultar em óbito. Os métodos tradicionais para determinação da concentração da bilirrubina baseiam-se na analise laboratorial de amostras de sangue e reagente específicos, no entanto demandam tempo de analise e oferecem um procedimento dolorido ao paciente. Os bilirrubinometros são equipamentos eletrônicos responsáveis pela medição indireta da concentração de bilirrubina a partir da analise espectrofotometria da reflexão dos raios incididos na pele. Os equipamentos disponíveis atualmente no mercado (BiliCheck e Minolta JM-103) utilizam um método evasivo (contato físico com a pele) e apresentam um elevado custo aos hospitais podendo chegar ate R$ 30.000,00. O projeto BiliUFPR surgiu em 2006 com intuito de fornecer um equipamento de baixo custo (inferior a R$ 200,00) e confiável para o diagnostico de icterícia. Neste trabalho serão apresentadas duas versões. A versão BiliUFPR V1.2 que e um aprimoramento de um projeto anterior e a versão BiliUFPR V2.0 que manteve o propósito de possuir um baixo um custo e propõe a medição sem contato físico o que evita o risco de contaminação e permite o acesso a lugares mais restritos (incubadoras). Palavras chaves:bilirrubinometro; icterícia; espectrofotometria; amplificador lockin | - |
Descrição: dc.description | Abstract: Jaundice is a clinical manifestation characterized by the yellow coloration of the skin, mucous membranes and sclera due to the high concentration of bilirubin in the bloodstream. In cases of diagnosis delayed, the patient may develop encephalic intoxication, resulting in encephalopathy that can result in death. Traditional methods for determining bilirubin concentration are based on laboratory analysis of blood sample and reagent samples, however they require a large time to analyze and offer a painful procedure to the patient. Bilirubinometers are electronic devices responsible for the indirect measurement of bilirubin concentration from the spectrophotometric analysis of the reflection of the rays applied on the skin. Currently, the equipment available on the market (BiliCheck and Minolta JM-103) uses an evasive method (physical contact with the skin) and presents a high cost to hospitals that can reach up to R $ 30,000.00. The BiliUFPR project was created in 2006 focused at providing a low cost equipment (less than R $ 200,00) and reliable for the diagnosis of jaundice. In this paper, two versions will be presented. The BiliUFPR version V1.2, which is an improvement of a previous project and the version BiliUFPR V2.0 that maintained the purpose of having a low cost and proposes the measurement without physical contact which avoids the risk of contamination and allows access to restricted places (incubators). Keywords: bilirubiometer; Jaundice; Spectrophotometry; lock-in amplifier | - |
Formato: dc.format | 82 f. : il. algumas color., gráfs., tabs. | - |
Formato: dc.format | application/pdf | - |
Formato: dc.format | application/pdf | - |
Relação: dc.relation | Disponível em formato digital | - |
Palavras-chave: dc.subject | Engenharia elétrica | - |
Palavras-chave: dc.subject | Ictericia | - |
Palavras-chave: dc.subject | Instrumentos e aparelhos médicos | - |
Palavras-chave: dc.subject | Hospitais - Equipamento | - |
Palavras-chave: dc.subject | Teses | - |
Título: dc.title | Analisador não invasivo da concentração de bilirrubina | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - Rede Paraná Acervo |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: