Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Lima, Antonio Adilson Soares de | - |
Autor(es): dc.contributor | Deonizio, Marili Doro Andrade | - |
Autor(es): dc.contributor | Universidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Odontologia | - |
Autor(es): dc.creator | Freitas, Isabela Roza Ricon de | - |
Data de aceite: dc.date.accessioned | 2019-08-21T23:34:02Z | - |
Data de disponibilização: dc.date.available | 2019-08-21T23:34:02Z | - |
Data de envio: dc.date.issued | 2017-02-13 | - |
Data de envio: dc.date.issued | 2017-02-13 | - |
Data de envio: dc.date.issued | 2016 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/1884/45358 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/1884/45358 | - |
Descrição: dc.description | Orientador: Prof. Dr. Antônio Adilson Soares de Lima | - |
Descrição: dc.description | Coorientadora: Profª. Drª. Marili Doro Andrade Deonizio | - |
Descrição: dc.description | Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Odontologia. Defesa: Curitiba, 2016 | - |
Descrição: dc.description | Inclui referências : f. 35-37;39-42 | - |
Descrição: dc.description | Área de concentração:Odontologia | - |
Descrição: dc.description | Resumo: Diversos sistemas mecanizados de Níquel/Titânio (NiTi) com diferentes características estruturais e propriedades têm sido desenvolvidos, pois existe uma constante busca pela melhor atuação em termos de quantidade de material removido das paredes do canal radicular, com fidelidade ao seu formato e efetiva sanificação da região. Este trabalho foi comparou, utilizando microtomografia computadorizada, os efeitos gerados em trinta incisivos inferiores pareados por tomografia computadorizada de feixe cônico (TCFC), divididos aleatoriamente em: „Grupo 1. (n = 15; WaveOne Gold 25.07) e „Grupo 2. (n = 15; ProDesign Logic 30.05). Volume total, diâmetro médio, índice de modelo de estrutura, área de superfície e porção não instrumentada foram os parâmetros avaliados. Imagens pré e pós-instrumentação foram realizadas com microtomógrafo SkyScan 1172 (potencial de 90 Kv; corrente de 112 µA sem filtro; tamanho de voxel: 25 µm; tempo de exposição = 0,3 s; resolução de câmera: 2000x1336 pixels; rotação: 0.4 º) e puderam ser observadas e avaliadas nos softwares aplicados. A análise estatística foi realizada por meio do software SPSS Statistics 2.0 tomando por base o valor de p < .001. Após o preparo, verificou-se que os dois sistemas proporcionaram aumento significativo de volume total, do diâmetro médio, do índice de modelo de estrutura e da área de superfície nos terços coronal, médio e apical dos canais (p <.001). Ambos os grupos demonstraram um volume não instrumentado sem diferença estatisticamente significativa (p> .001), sendo que o Grupo 2 apresentou um valor maior que o Grupo 1. Os dois sistemas proporcionaram redução no valor de espessura de dentina, nas quatro paredes dos terços médio e apical (p< .001). A partir destes resultados, demonstra-se que os dois sistemas proporcionam modificações estruturais semelhantes nos canais radiculares oval-achatados, quando utilizados no preparo mecânico do tratamento endodôntico. Palavras-chaves: Endodontia, Microtomografia por Raio-X, Preparo de Canal Radicular, Instrumentação mecanizada. | - |
Descrição: dc.description | Abstract: Several Nickel / titanium (NiTi) mechanized systems with different structural characteristics and properties have been developed and produced. The methods of design and manufacturing can significantly affect the clinical performance of NiTi rotary instruments. So there is a constant search for the best performance in terms of amount of material removed from the root canal walls with fidelity to its format and effective sanitization of the area. The aim of this study was to compare three-dimensional effects generated by mechanical instrumentation with Waveone Gold and ProDesign Logic in oval-flattened root canals geometry using computed micro-tomography. Thirty mandibular incisors were analyzed randomly grouped in 'Group 1' (n = 15) prepared by ProDesign Logic 30.05, and "Group 2" (n = 15) prepared by WaveOne Gold 25.07 system. Total volume, mean diameter, structure model index, surface area, dentin thickness and not instrumented portion were evaluated parameters. Images pre and post instrumentation were performed by SkyScan 1172 (potential of 90 kV; current of 112 uA without filter; voxel size: 25 uM; exposure time = 0.3 s; Camera Resolution: 2000x1336 pixels; rotation: 0.4 °) and were observed and evaluated in the applied software. Statistical analysis was performed using SPSS 2.0 software (p value <.001). After preparation, both systems provided a significant increase in the total volume, in the mean diameter, in the model structure index and in the surface area in the coronal thirds and apical (p value <.001). Both groups showed a not instrumented portion with no statistically significant difference (p value > .001), and the Group 2 showed a slightly higher value than Group 1. The two systems showed reduction in the dentin thickness in the four walls in medium and apical thirds (p value < .001), with no difference statistically significant between both (p value > .001). From these results, it can be show that the two systems provided similar structural changes in the oval-flattened root canals, when used in the mechanical preparation of the endodontic treatment. Keywords: endodontics, X-ray microtomography, root canal preparation, rotatory instrumentation. | - |
Formato: dc.format | 56 f. : il., alguma color., grafs., tabs. | - |
Formato: dc.format | application/pdf | - |
Formato: dc.format | application/pdf | - |
Relação: dc.relation | Disponível em formato digital | - |
Palavras-chave: dc.subject | Endodontia | - |
Palavras-chave: dc.subject | Dentes - Radiografia | - |
Palavras-chave: dc.subject | Canal radicular - Tratamento | - |
Título: dc.title | Efeitos dos sistemas mecanizados waveone gold e prodesign logic na geometria do canal radicular avaliados por micro-tomografia computadorizada | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - Rede Paraná Acervo |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: