Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Doubek, Alvaro | - |
Autor(es): dc.contributor | Campos, Milton de Azevedo | - |
Autor(es): dc.contributor | Universidade Federal do Paraná. Setor de Ciências da Terra. Programa de Pós-Graduação em Ciências Geodésicas | - |
Autor(es): dc.creator | Cordini, Jucilei | - |
Data de aceite: dc.date.accessioned | 2019-08-21T23:57:34Z | - |
Data de disponibilização: dc.date.available | 2019-08-21T23:57:34Z | - |
Data de envio: dc.date.issued | 2015-10-28 | - |
Data de envio: dc.date.issued | 2015-10-28 | - |
Data de envio: dc.date.issued | 1991 | - |
Fonte completa do material: dc.identifier | http://hdl.handle.net/1884/37187 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/1884/37187 | - |
Descrição: dc.description | Orientadores: Alvaro Doubek e Milton de Azevedo Campos | - |
Descrição: dc.description | Dissertação (mestrado) - Universidade Federal do Paraná | - |
Descrição: dc.description | Resumo: A calibração completa de um IMED envolve várias determinações de erros sistemáticos, cujos valores se modificam em função do uso constante e envelhecimento do equipamento. Parte desta calibração destina-se à determinação do erro cíclico em laboratório, normalmente conduzida sobre uma Linha de Teste. Este trabalho foi orientado no sentido de implementar e tornar operacional a Linha de Teste da UFPr , afim de adequá-la à seus propósitos e se transformar num instrumento útil para pós-graduandos, pesquisadores e usuários. Dentre os trabalhos executados e melhorias introduzidas à Linha de Teste, destaca-se a implantação de cinco sistemas refletores (espelhos) que possibilita a obtenção de distâncias superiores a 100 metros. Seis instrumentos de MED foram testados utilizando-se 03 e 05 espelhos normais, num total de 12 testes realizados; dois testes adicionais com espelhos frontais foram também realizados. Os resultados são apresentados e comprovam a eficiência do método e a praticidade do procedimento adotado. | - |
Descrição: dc.description | Abstract: The complete calibration of a EDMI implicate in many determinations of systematic errors, whose values modify as a function of the constant use and the aging of the equipment. Part of this calibration is for determination of the cyclic error in laboratory, normally carried out over a Test Line. This work was oriented in the meaning of to implement and at turning operational the Test Line of the UFPr, with the aim to adapt it to its purpose and at turning it a useful instrument to post-graduate, researchers and users. Among the work carried out and the improvement introduced to the Test Line, it must be distinguished the implantation of five reflector systems (mirrors) that make possible to obtain distances over a hundred meters. Six EDMI instruments were tested by the use of three and five normal mirrors making a total of twelve realized tests; two supplementary tests with frontal mirror were also realized. The results are show and they confirm the efficiency of the method used and the practicality of the procedure adopted. | - |
Formato: dc.format | xiii, 138 f. : il. ; 29 cm. | - |
Formato: dc.format | application/pdf | - |
Formato: dc.format | application/pdf | - |
Relação: dc.relation | Disponível em formato digital | - |
Palavras-chave: dc.subject | Calibração | - |
Palavras-chave: dc.subject | Teses | - |
Palavras-chave: dc.subject | Levantamentos geologicos | - |
Palavras-chave: dc.subject | Geodesia | - |
Palavras-chave: dc.subject | T 526.3 | - |
Título: dc.title | Determinação do erro ciclico em distanciometros eletronicos | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional - Rede Paraná Acervo |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: