Evaluation of Microstrain in the Regions Surrounding Morse Taper and External Hexagon Implants

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorCourses in Dentistry (IEEP - Instituto de Excelência em Ensino e Pesquisa)-
Autor(es): dc.creatorDe Melo Moreno, André Luiz-
Autor(es): dc.creatorCampaner, Marcio-
Autor(es): dc.creatorDe Moraes Melo Neto, Clóvis Lamartine-
Autor(es): dc.creatorDe Araújo Moreno, Nathaly Vilene-
Autor(es): dc.creatorDos Santos, Daniela Micheline-
Autor(es): dc.creatorGoiato, Marcelo Coelho-
Data de aceite: dc.date.accessioned2025-08-21T18:17:01Z-
Data de disponibilização: dc.date.available2025-08-21T18:17:01Z-
Data de envio: dc.date.issued2025-04-29-
Data de envio: dc.date.issued2024-07-16-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1055/s-0044-1787696-
Fonte completa do material: dc.identifierhttps://hdl.handle.net/11449/309627-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/309627-
Descrição: dc.descriptionObjective The aim of this study was to compare the Morse taper (MT) + titanium base (Ti-Base) abutment with the external hexagon (EH) + Ti-Base abutment by using the strain gauge method in the mesial, distal, and apical-buccal areas around these types of implants. Materials and Methods This study investigated two groups, MT and EH, each comprising five polyurethane samples with a dental implant (3.75 × 11.5 mm) in the area of artificial tooth 15. The strain gauges were glued to the mesial, distal, and apical-buccal polyurethane areas of all samples in relation to the implant. Ti-Base nonangled abutments were installed on the implants in each group. Ten identical zirconia crowns were constructed by scanning and milling and were subsequently cemented onto the Ti-base abutments with calcium hydroxide cement. Then, an axial load of 100 N was applied to the occlusal region of the zirconia crowns, and strain gauge measurements were taken. Statistical Analysis Strain gauge data were assessed by a two-way analysis of variance (ANOVA) with implant connection and strain gauge position factors, followed by the Bonferroni test (p < 0.05). Results The MT group showed significantly lower microstrain values in the mesial and apical strain gauges compared to the EH group. Conclusion The MT group exhibited less microstrain in the mesial and apical areas of the polyurethane samples near the implant. Consequently, the MT connection was considered more biomechanically advantageous.-
Descrição: dc.descriptionDepartment of Dental Materials and Prosthodontics São Paulo State University (UNESP) School of Dentistry, São Paulo-
Descrição: dc.descriptionCourses in Dentistry (IEEP - Instituto de Excelência em Ensino e Pesquisa), Amazonas-
Descrição: dc.descriptionDepartment of Dental Materials and Prosthodontics São Paulo State University (UNESP) School of Dentistry, São Paulo-
Formato: dc.format180-186-
Idioma: dc.languageen-
Relação: dc.relationEuropean Journal of Dentistry-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectdental implant-
Palavras-chave: dc.subjectexternal hexagon-
Palavras-chave: dc.subjectmicrostrain-
Palavras-chave: dc.subjectmorse taper-
Palavras-chave: dc.subjectstrain gauge measurements-
Palavras-chave: dc.subjectTi-Base abutment-
Título: dc.titleEvaluation of Microstrain in the Regions Surrounding Morse Taper and External Hexagon Implants-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp