Elastic Deflection Study of Nickel‑Titanium Orthodontic Wires: 3‑Point Bending Test X Clinical Simulation Device

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorHospital for Rehabilitation of Craniofacial Anomalies-
Autor(es): dc.contributorUniversidade de São Paulo (USP)-
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorUniversity of North Parana-
Autor(es): dc.creatorSathler, Renata-
Autor(es): dc.creatorde Freitas, Marcos Roberto-
Autor(es): dc.creatorSoufen, Carlos Alberto-
Autor(es): dc.creatorZanda, Marcelo-
Autor(es): dc.creatorFernandes, Thais Maria Freire-
Autor(es): dc.creatorMaranhão, Olga Benário Vieira-
Autor(es): dc.creatorGarib, Daniela Gamba-
Autor(es): dc.creatorJanson, Guilherme-
Data de aceite: dc.date.accessioned2025-08-21T19:28:42Z-
Data de disponibilização: dc.date.available2025-08-21T19:28:42Z-
Data de envio: dc.date.issued2025-04-29-
Data de envio: dc.date.issued2019-12-31-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.4103/jid.jid_78_18-
Fonte completa do material: dc.identifierhttps://hdl.handle.net/11449/309163-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/309163-
Descrição: dc.descriptionIntroduction: The purpose of this study was to compare the most usual types of bending tests used to evaluate nickel-titanium orthodontic wires: the 3-point bending test and the clinical simulation device (CSD). Materials and Methods: Eleven groups of 0.014‑inch nickel‑titanium orthodontic wires of six different brands were tested. A 3342 Instron universal testing machine with a 10 N load cell was used, and the ISO 15.841 regulation was followed. T-tests were used to compare the evaluations. Results: At a deflection of 0.5 mm, the device released significantly lighter forces then the 3‑point test. However, at deflections of 1; 2 and 3 mm, the device released significantly heavier forces. Conclusion: Because of the several differences between the tests and the inconsistency of the CSD, the 3‑point bending test was elected the most reliable method to evaluate the elastic deflection of nickel-titanium orthodontic wires.-
Descrição: dc.descriptionDepartment of Dentistry Hospital for Rehabilitation of Craniofacial Anomalies-
Descrição: dc.descriptionDepartment of Orthodontics Bauru Dental School University of São Paulo-
Descrição: dc.descriptionDepartment of Mechanical Engineering Faculty of Engineering Universidade Estadual Paulista Júlio De Mesquita Filho-
Descrição: dc.descriptionDepartment of Orthodontics University of North Parana-
Descrição: dc.descriptionDepartment of Mechanical Engineering Faculty of Engineering Universidade Estadual Paulista Júlio De Mesquita Filho-
Formato: dc.format29-34-
Idioma: dc.languageen-
Relação: dc.relationJournal of Interdisciplinary Dentistry-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectCopper‑nickel‑titanium-
Palavras-chave: dc.subjectorthodontic wires-
Palavras-chave: dc.subjecttitanium nickelide-
Título: dc.titleElastic Deflection Study of Nickel‑Titanium Orthodontic Wires: 3‑Point Bending Test X Clinical Simulation Device-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.