Comparative analysis of microgaps in angled and straight components: a laboratory study

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidade Federal de Sergipe (UFS)-
Autor(es): dc.contributorFaculdade de Odontologia-
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.creatorLobo, Yuri Lins-
Autor(es): dc.creatorMendes, Giovanna Nascimento-
Autor(es): dc.creatorSantana, Lucas Alves da Mota-
Autor(es): dc.creatorFloresta, Lara Gois-
Autor(es): dc.creatorMarqueti, Antônio Carlos-
Autor(es): dc.creatorTakeshita, Wilton Mitsunari-
Autor(es): dc.creatorTrento, Cleverson Luciano-
Data de aceite: dc.date.accessioned2025-08-21T16:18:10Z-
Data de disponibilização: dc.date.available2025-08-21T16:18:10Z-
Data de envio: dc.date.issued2025-04-29-
Data de envio: dc.date.issued2023-12-31-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1590/1807-2577.02424-
Fonte completa do material: dc.identifierhttps://hdl.handle.net/11449/304694-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/304694-
Descrição: dc.descriptionIntroduction: The dental implant rehabilitation protocol is a well-established treatment option for edentulous patients with a high success rate. However, there are factors that can lead to difficulty in continuation and even complete loss of rehabilitation. Microgaps are spaces found between the implant and prosthetic abutment that are caused by the limit of precision in the manufacturing of the implant. This space can cause micromovements and bacterial microleakage that can compromise the long-term useful life of the implant. Objective: Measure and evaluate microgaps in angled and straight implants using scanning electron microscopy. To carry out the study, a total of 30 SIN® osseointegrated implants were used, 15 of which were straight and 15 angled. Material and method: For the comparative analysis of these components, scanning electron microscopy was used, carried out by a properly calibrated and experienced researcher. Result: It was observed that the microgap measurements of both components are in accordance with the clinically acceptable values presented in the literature, however the microgap values of the angled components were considerably higher compared to the straight components. Conclusion: Although the values presented corroborate the data presented in the literature, additional studies are necessary for a more comprehensive and in-depth understanding of the relationship between the microgaps of the morse cone system components.-
Descrição: dc.descriptionFinanciadora de Estudos e Projetos-
Descrição: dc.descriptionCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
Descrição: dc.descriptionUFS – Universidade Federal de Sergipe Faculdade de Odontologia, SE-
Descrição: dc.descriptionUNIT – Universidade Tiradentes Faculdade de Odontologia, SE-
Descrição: dc.descriptionUNESP – Universidade Estadual Paulista “Júlio de Mesquita Filho” Faculdade de Odontologia de Araçatuba Departamento de Diagnostico e Cirurgia, SP-
Descrição: dc.descriptionUNESP – Universidade Estadual Paulista “Júlio de Mesquita Filho” Faculdade de Odontologia de Araçatuba Departamento de Diagnostico e Cirurgia, SP-
Descrição: dc.descriptionCAPES: 001-
Idioma: dc.languageen-
Relação: dc.relationRevista de Odontologia da UNESP-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectdental implant-abutment design-
Palavras-chave: dc.subjectDental implants-
Palavras-chave: dc.subjectdentistry-
Título: dc.titleComparative analysis of microgaps in angled and straight components: a laboratory study-
Título: dc.titleAnálise comparativa de microgaps em componentes angulares e retos: um estudo de laboratório-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.