Comparison of invasive and non-invasive blood pressure monitoring in Cuniculus paca (Spotted paca)

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorUniversidad CES-
Autor(es): dc.contributorUniversidade Estadual Paulista (UNESP)-
Autor(es): dc.contributorUniversidade Federal dos Vales do Jequitinhonha e Mucuri-
Autor(es): dc.contributorSeropédica-
Autor(es): dc.contributorUniversidad de la Tolima-
Autor(es): dc.creatorGrisales-Gutiérrez, Daniel Guillermo-
Autor(es): dc.creatorMarcusso, Paulo Fernandes-
Autor(es): dc.creatorGasser, Beatriz-
Autor(es): dc.creatorOspina-Argüelles, Diego Alejandro-
Autor(es): dc.creatorBarro, Felipe F.P.C.-
Autor(es): dc.creatorUscategui, Ricardo Andres Ramirez-
Data de aceite: dc.date.accessioned2025-08-21T15:11:36Z-
Data de disponibilização: dc.date.available2025-08-21T15:11:36Z-
Data de envio: dc.date.issued2025-04-29-
Data de envio: dc.date.issued2024-06-18-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.21708/avb.2024.18.2.12120-
Fonte completa do material: dc.identifierhttps://hdl.handle.net/11449/296936-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/296936-
Descrição: dc.descriptionCuniculus paca, a South American wild rodent with zootechnical potential, requires anesthesia for management procedures. However, limited information is available regarding safe monitoring of this animal under anesthesia. This study aimed to compare with gold standard invasive method and validate non-invasive blood pressure measurements using an oscillometric monitor in Cuniculus paca. Eight healthy adult females undergoing general anesthesia for follicular aspiration were included. Systolic, diastolic, and mean arterial pressures were measured simultaneous using, oscillometric non-invasive monitor with its cuff placed on the radial artery and an invasive catheter placed in the dorsal metatarsal artery. Measurements were compared using the t-test, correlated by Pearson test, and analyzed using the Bland-Altman concordance test. The results indicated that only systolic pressure measured by non-invasive oscillometric methos was similar to the pressure measurement by invasive method (P=0.6372, r=0.5969, bias 0.59±20.9 mmHg); while mean and diastolic pressures were underestimated by the non-invasive method. In conclusion, non-invasive oscillometric monitor provides a valid and reliable method for systolic blood pressure measurement in Cuniculus paca under general anesthesia.-
Descrição: dc.descriptionGrupo de Investigación INCA-CES Facultad de Medicina Veterinaria y Zootecnia Universidad CES-
Descrição: dc.descriptionFaculdade de Medicina Veterinária e Zootecnia Universidade Estadual Paulista-
Descrição: dc.descriptionInstituto de Ciências Agrárias Universidade Federal dos Vales do Jequitinhonha e Mucuri-
Descrição: dc.descriptionInstituto de Veterinária Universidade Federal Rural do Rio de Janeiro Seropédica-
Descrição: dc.descriptionDepartamento de Sanidad Animal Facultad de Medicina Veterinaria y Zootecnia Universidad de la Tolima-
Descrição: dc.descriptionFaculdade de Medicina Veterinária e Zootecnia Universidade Estadual Paulista-
Formato: dc.format135-140-
Idioma: dc.languageen-
Relação: dc.relationActa Veterinaria Brasilica-
???dc.source???: dc.sourceScopus-
Palavras-chave: dc.subjectgeneral anesthesia-
Palavras-chave: dc.subjectinvasive monitoring-
Palavras-chave: dc.subjectneotropical rodent-
Palavras-chave: dc.subjectoscillometric sphygmomanometer-
Palavras-chave: dc.subjectwild animals-
Título: dc.titleComparison of invasive and non-invasive blood pressure monitoring in Cuniculus paca (Spotted paca)-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.