Descrição: dc.descriptionObjetivo: Avaliar a influência de diferentes resoluções espaciais de escaneamento de placas de fósforo radiográficas pela da técnica de análise de textura (AT). Material e Métodos: foram realizadas radiografias digitais em sensores de uma escala de alumínio com 05 degraus (0,5mm de incremento), com tempos de exposição radiográficos de 0,10s, 0,20s. Estes foram escaneados em diferentes resoluções espaciais - 10, 20, 25 e 40 lp/mm - com 10 repetições para cada resolução. Nas imagens, no Software MaZda 4.6, foram determinadas regiões de interesse (ROI) envolvendo individualmente as imagens dos degraus de 0,5; 1,5 e 2,5mm. Foram calculados, pela matriz de co-orrência (COM) 11 parâmetros de textura de cada ROI. Realizada a análise exploratória dos dados e as resoluções espaciais foram comparadas em cada combinação de tempo e espessura pelo ANOVA, seguida do teste de comparações múltiplas de Tukey. Resultados: para o tempo de 0,10s, 08 parâmetros de textura, indicadores de menor homogeneidade (AngScMom; Contrast; InvDfMom; SumAverg; Entropy; DifVarnc; DifEntrp e Correlat), apresentaram diferenças estatisticamente significantes (p<0,05) entre as resoluções espaciais, independente da espessura da imagem, estes parâmetros assumiram maiores valores para resoluções entre 10 e 20lp/mm; para tempo de exposição de 0,20s, os parâmetros de textura Correlat e SumAverg, indicadores de menor uniformidade, apresentaram diferenças estatisticamente significantes (p<0,05) entre as resoluções espaciais estudadas, independente da espessura da imagem, com maiores valores para 10lp/mm e 20Lp/mm. Conclusões: Pela AT, menores resoluções de escaneamento suscitam em imagens com menor homogeneidade e uniformidade, independente da espessura do objeto.-
Descrição: dc.descriptionObjective: To assess the influence of different spatial resolutions in scanning radiographic phosphor plates using texture analysis (TA). Materials and Methods: Digital radiographs were acquired using sensors of an aluminum step wedge with 5 steps (0.5mm increment), with radiographic exposure times of 0.10s and 0.20s. These were scanned at different spatial resolutions - 10, 20, 25, and 40 lp/mm - with 10 repetitions for each resolution. In the images, regions of interest (ROIs) were determined using MaZda 4.6 software, individually encompassing images of the 0.5, 1.5, and 2.5mm steps. Eleven texture parameters of each ROI were calculated using the co-occurrence matrix (COM). Exploratory data analysis was performed, and spatial resolutions were compared in each combination of time and thickness using ANOVA, followed by Tukey's multiple comparison test. Results: For an exposure time of 0.10s, 8 texture parameters, indicative of lower homogeneity (AngScMom; Contrast; InvDfMom; SumAverg; Entropy; DifVarnc; DifEntrp, and Correlat), showed statistically significant differences (p<0.05) between spatial resolutions, regardless of image thickness, with these parameters assuming higher values for resolutions between 10 and 20 lp/mm. For an exposure time of 0.20s, the texture parameters Correlat and SumAverg, indicative of lower uniformity, showed statistically significant differences (p<0.05) between the spatial resolutions studied, regardless of image thickness, with higher values for 10 and 20 lp/mm. Conclusions: According to TA, lower scanning resolutions result in images with lower homogeneity and uniformity, regardless of the object thickness.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Estadual Paulista (UNESP)-
Direitos: dc.rightsinfo:eu-repo/semantics/restrictedAccess-
Palavras-chave: dc.subjectRadiografia dentária-
Palavras-chave: dc.subjectProcessamento de imagem assistida por computador-
Palavras-chave: dc.subjectIntensificação de Imagem Radiográfica-
Palavras-chave: dc.subjectRadiography, dental-
Palavras-chave: dc.subjectImage processing, computer-assisted-
Palavras-chave: dc.subjectRadiographic image enhancement-
Título: dc.titleEstudo da influência de diferentes resoluções de escaneamento de placas de fósforo de sistemas radiográficos digitais por meio da técnica de análise de textura-
Título: dc.titleStudy of the influence of different scanning resolutions of phosphor plates in digital radiographic systems through texture analysis-