Efeito da termociclagem na avaliação da resistência flexural e módulo de elasticidade em diferentes resinas compostas diretas

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorTorres, Carlos Rocha Gomes [Unesp]-
Autor(es): dc.creatorSantos, Julia Maria Longhi Ribeiro dos-
Data de aceite: dc.date.accessioned2025-08-21T18:04:29Z-
Data de disponibilização: dc.date.available2025-08-21T18:04:29Z-
Data de envio: dc.date.issued2024-03-27-
Data de envio: dc.date.issued2024-03-27-
Data de envio: dc.date.issued2024-03-07-
Fonte completa do material: dc.identifierhttps://hdl.handle.net/11449/254790-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/11449/254790-
Descrição: dc.descriptionObjetivo: O objetivo deste estudo é avaliar o efeito da termociclagem na resistência flexural, módulo de elasticidade e microdureza de diferentes resinas compostas de uso direto.Material e Métodos: Um total de 120 espécimes foram obtidos utilizando uma matriz de aço inoxidável com as especificações da norma ISO 4049 nas seguintes dimensões para comprimento; largura e altura: 25x2x2 (mm). Foram utilizadas 6 diferentes marcas comerciais de resina composta (n=20): TP- Tetric Prime; GA- G-aenial A’chord; NS- Neo Spectra ST HV; SS- Simple Shade; FU- Filtek Universal e AF5- Admira Fusion 5. Os incrementos de resina foram feitos com a matriz sob uma placa de vidro lisa. A polimerização foi feita por 40 segundos à 600 mW/cm2 e os excessos de material foram removidos com discos abrasivos e de polimento. Metade dos espécimes de cada grupo (n=10) foram armazenados em água (24h, 37ºC) enquanto a outra metade dos espécimes foram submetidos à termociclagem por 3.000 ciclos, para posteriormente ser realizado o teste de flexão 3 pontos através de máquina universal de ensaios (EMIC - DL 200MF) (50kg, 1mm/min Resultados: Diferenças significativas foram observadas para os fatores tipo de resina e termociclagem em relação à resistência flexural, mas não para a interação entre eles. Os resultados do teste de Tukey foram: Resina - GA84.56(10.24)a, TP-102,1(7.77)b, SS-110.02(12.11)bc, AF5-110.24(11.37)bc, NS112.91(10.37)c, FU-144,30(9.36)d. Termociclagem – Com-105,97(20.80)a, Sem115,41(19.18)b. Para o módulo de elasticidade, foram observadas diferenças para os dois fatores em estudo e para a interação entre eles (p<0,05). Os resultados para o tipo de resina foram: Resina – GA-8,18(0.45)a, TP-8,72(0.34)b, NS-9,13(0.34)c, SS-10,24(0.34)d, AF5-10,44(0.57)d, FU-11,50(0.36).Termociclagem – Sem9,56(1.15)a, Com-9,84(1.24)b Conclusão: A termociclagem reduziu a resistência flexural, mas aumentou o módulo de elasticidade; G-aenial A'chord apresentou os menores resultados para resistência flexural e módulo de elasticidade, enquanto Filtek Universal apresentou os maiores valores.-
Descrição: dc.descriptionObjective: The objective of this study was to evaluate the effect of thermocycling on the flexural strength and elastic modulus of different direct resin composites. Material and Methods: A total of 120 specimens were obtained using a stainless steel matrix with ISO 4049 specifications in the following dimensions for length; width and height: 25x2x2 (mm). 6 different commercial brands of composite resin were used (n=20): TP- Tetric Prime; GA- G-aenial A’chord; NS- Neo Spectra ST HV; SS- Simple Shade; FU- Filtek Universal and AF5- Admira Fusion 5. The resin increments were made with the matrix under a smooth glass plate. The polymerization was carried out for 40 seconds at 600 mW/cm2 and excess material was removed with abrasive and polishing discs. Half of the specimens from each group (n=10) were stored in water (24h, 37ºC) while the other half of the specimens were subjected to thermocycling for 3,000 cycles, and then the 3-point flexion test was carried out using a universal testing machine. (EMIC - DL 200MF) (50kg, 1mm/min). Results: Significant differences were observed for the factors resin type (p=0.001) and thermocycling (p=0.001) in relation to flexural strength, but not for the interaction between them. Tukey's test results were: Resin - GA-84.56(10.24)a, TP-102.1(7.77)b, SS110.02(12.11)bc, AF5-110.24(11.37)bc, NS-112.91(10.37) c, FU-144,30(9.36)d. Thermocycling – With-105.97(20.80)a, Without-115.41(19.18)b. For the elastic modulus, differences were observed for the two factors under study and for the interaction between them (p<0.05). The results for the type of resin were: Resin – GA-8.18(0.45)a, TP-8.72(0.34)b, NS-9.13(0.34)c, SS-10.24(0.34)d , AF5- 10.44(0.57)d, FU-11.50(0.36). Thermocycling – Without-9.56(1.15)a, With9.84(1.24)b. Conclusion: Thermocycling reduced flexural strength but increased the elastic modulus; G-aenial A'chord presented the lowest results for flexural strength and elastic modulus, while Filtek Universal presented the highest values.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Estadual Paulista (UNESP)-
Direitos: dc.rightsinfo:eu-repo/semantics/restrictedAccess-
Palavras-chave: dc.subjectMódulo de elasticidade-
Palavras-chave: dc.subjectResina composta-
Palavras-chave: dc.subjectResina de cor simplificada-
Palavras-chave: dc.subjectResistência Flexural-
Palavras-chave: dc.subjectTermociclagem-
Palavras-chave: dc.subjectElastic Modulus-
Palavras-chave: dc.subjectComposite Resin-
Palavras-chave: dc.subjectSimplified shade composite resin-
Palavras-chave: dc.subjectFlexural Strength-
Palavras-chave: dc.subjectThermocycling-
Título: dc.titleEfeito da termociclagem na avaliação da resistência flexural e módulo de elasticidade em diferentes resinas compostas diretas-
Título: dc.titleEffect of thermocycling on the evaluation of flexural strength and elastic modulus in different direct composite resins-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional - Unesp

Não existem arquivos associados a este item.